Cabletron Systems 38, FOMIM-32, 36 manual Link Test

Page 23

Chapter 3: Testing and Troubleshooting

5.Disconnect the jumpers from the barrel connector.

6.Using the jumper, attach the optical power meter to one end of one strand of the link segment.

7.Using the other jumper, attach the other end of the same strand to the optical source unit.

8.Note the reading on the optical power meter. This is your test level.

9.Subtract the reference level found in Step 4 from the test level to find your dB loss for the fiber optic link segment, i.e.,

dB loss = Test Level - Reference Level.

10.Verify that the reading on the receive unit falls within the range indicated by the Receive Sensitivity and Maximum Receive Input Power specifications listed in the Fiber Optic Interface section of Appendix A.

11.Repeat Steps 6 through 10 for the other strand in the link segment.

If the fiber optic link segment does not meet the specifications, it may be contaminated with dust, dirt, or other contaminants. Try cleaning the connection at each end of the cable with denatured alcohol, using a soft, clean, lint free cloth, then repeat the test.

If this does not work, contact Cabletron Systems technical support.

3.1.2Link Test

To verify the physical link between your devices, check the LNK LEDs on your FOMIM and receiving device for the applicable port. If the LEDs are lit, the proper connection has been made.

If the LEDs are not lit, perform the following procedure, using a Cabletron Systems FOT-F3 Fiber Optic Transceiver at the other end of the cable.

1.Check that power is being supplied to both the FOMIM in the MMAC chassis and the device at the other end of the link.

2.Reverse the fiber optic cable ends at either the applicable port on the module or at the device.

3.Check if the LEDs are lit.

3-2

FOMIM User’s Guide

Image 23
Contents USER’S Guide Fomim User’s Guide FCC NoticeCabletron SYSTEMS, INC. Program License Agreement DOC NoticeVcci Notice United States Government Restricted Rights Exclusion of Warranty and Disclaimer of LiabilityCabletron Software Program License PO Box Rochester, NH Declaration of ConformityContents Contents Fomim User’s Guide Chapter Introduction Using this ManualIntroduction Distance and Cable Type Document ConventionsFiber Optic Media Interface Modules Lanview Status Monitoring System Multi Media Access CentersLanview Status Monitoring System Getting Help Related ManualsGetting Help Fomim User’s Guide Fiber Optic Network Design Guidelines Chapter Network Requirements InstallationNetwork Cable Requirements Unpack the module as follows Unpacking the FomimInstalling the Fomim Installing the Fomim Into the MmacST Connector Insertion Connecting Fiber Optic Cabling to the FomimConnecting Fiber Optic Cabling to the Fomim Fomim User’s Guide Testing the Fiber Optic Link Segment Chapter Testing and TroubleshootingInstallation Test Link Test PRE-INSTALLATION Test Pre-Installation Test Using LanviewUsing Lanview Fomim User’s Guide Operating Specifications Appendix a Fomim SpecificationsAppendix a Fomim Specifications Environmental RequirementsPhysical Properties Agency ApprovalsFomim User’s Guide ERR LED IndexIndex Index-2 Fomim User’s Guide