Cabletron Systems 38, FOMIM-32, 36 manual Using Lanview

Page 26

 

 

 

Using LANVIEW

 

Table 3-1 LANVIEW Troubleshooting

 

 

 

 

 

 

 

Error

Led

Color

Description

Condition/Recommended

 

 

 

Action

 

 

 

 

LNK

Green

When on, a link is

If off, the link between the port

(Link/

 

established

and fiber device has been

Fiber

 

between the

broken.

Port)

 

FOMIM Fiber port

 

 

 

and the fiber device

Check the connectors at each

 

 

at the other end of

end of the segment to ensure

 

 

the segment. LED is

that they are free of dust. Clean

 

 

on as long as the

the connectors if necessary.

 

 

link is maintained.

Reconnect the segment and

 

 

 

check the Link LED again.

 

 

 

 

RCV

Yellow

When flashing the

If off, the FOMIM is not

(Receive)

 

FOMIM is receiving

receiving packets.

 

 

data packets from

 

 

 

segments connected

Check that the module is firmly

 

 

to the associated

installed in the MMAC.

 

 

port.

 

 

 

 

 

CLN

Red

When flashing, a

Excessive flashing or on solid

(Collision

 

collision is being

indicates excessive collisions.

Present)

 

detected on one or

 

 

 

more segments

 

 

 

connected to the

 

 

 

MMAC. Note that

 

 

 

periodic flashing is

 

 

 

normal.

 

 

 

 

 

ERR

Red

Remains lit when the

 

(Error)

 

temperature within

 

 

 

the MMAC chassis

 

 

 

rises above 40°C.

 

 

 

 

 

If you are not able to resolve a problem with your FOMIM, call Cabletron Systems Technical Support for assistance (see Chapter 1, Section 1.6, Getting Help).

FOMIM User’s Guide

3-5

Image 26
Contents USER’S Guide FCC Notice Fomim User’s GuideCabletron SYSTEMS, INC. Program License Agreement DOC NoticeVcci Notice United States Government Restricted Rights Exclusion of Warranty and Disclaimer of LiabilityCabletron Software Program License Declaration of Conformity PO Box Rochester, NHContents Contents Fomim User’s Guide Using this Manual Chapter IntroductionIntroduction Distance and Cable Type Document ConventionsFiber Optic Media Interface Modules Multi Media Access Centers Lanview Status Monitoring SystemLanview Status Monitoring System Related Manuals Getting HelpGetting Help Fomim User’s Guide Fiber Optic Network Design Guidelines Chapter Network Requirements InstallationNetwork Cable Requirements Unpacking the Fomim Unpack the module as followsInstalling the Fomim Into the Mmac Installing the FomimConnecting Fiber Optic Cabling to the Fomim ST Connector InsertionConnecting Fiber Optic Cabling to the Fomim Fomim User’s Guide Testing the Fiber Optic Link Segment Chapter Testing and TroubleshootingInstallation Test Link Test PRE-INSTALLATION Test Using Lanview Pre-Installation TestUsing Lanview Fomim User’s Guide Appendix a Fomim Specifications Operating SpecificationsEnvironmental Requirements Appendix a Fomim SpecificationsAgency Approvals Physical PropertiesFomim User’s Guide Index ERR LEDIndex Index-2 Fomim User’s Guide