Cabletron Systems E2100, E1100, E3100 manual Fiber Optic Interface Fiber Optic Ports

Page 36

MAKING NETWORK CONNECTIONS

Length - The maximum fiber optic cable length is 2 km (6558 feet), if system budgets are met. However, IEEE 802.3 FOIRL (Fiber Optic Inter-Repeater Link) specifications specify a maximum of 1 km (3279 feet).

3.3.2 Fiber Optic Interface (Fiber Optic Ports)

Ex040 and Ex040-X:

ST fiber optic ports

 

Parameter

Typical

Worst

Worst

Typical

 

Value

Case

Case

Budget

Receive

 

 

Budget

 

Sensitivity:

-30.5 dBm

-28.0 dBm

Peak Input

 

 

 

 

Power:

-7.6 dBm

-8.2 dBm

Transmitter Power:

 

 

 

50/125 μm fiber:

-13.0 dBm

-15.0 dBm

13.0 dB

17.5 dB

62.5/125 μm fiber: -10.0 dBm

-12.0 dBm

16.0 dB

20.5 dB

100/140 μm fiber:

-7.0 dBm

-9.0 dBm

19.0 dB

23.5 dB

Error Rate:

 

Better than 10-10bit error rate.

NOTE: The transmitter power levels and receive sensitivity levels given above are Peak Power Levels after optical overshoot. A Peak Power Meter must be used to correctly compare the values given above to those measured on any port. If Power Levels are measured with an Average Power Meter, add 3 dBm to the average power measurement to correctly compare average power values to the peak power values.

Page 3-8

Image 36
Contents Desktop Network Interface Products Page FCC Notice Contents Making Network Connections Appendix a ADDRESS/INTERRUPT Tables IndexUsing this Manual Chapter IntroductionAdapter Features ConnectivityThin Ethernet Port 3 10BASE-T Twisted Pair PortFiber Optic Ports Jabber ProtectionLanview LEDs Collision Present CLN Software StatisticsRelated Manuals Chapter Installation Adapter ModelsModel Number References E1100/E2100 Series AdaptersPreparing the E1100 for Installation Unpacking the AdapterCopying the Software Preparing the E2100 for Installation E1112 AdapterSetting the I/O Base Address Jumper JP1, E1100/E2100 I/O base address Jumper Pins 220 280 300Installing a Boot Prom I/O Address Space RequirementsInstalling the E1100/E2100 Adapters Backplate Detail Installing the E1100 Series Adapter Installing the E3100 Series Adapters Preparing the E3100 Series for Installation2 E3100 Series Boot Prom Installing the E3100 Adapter E3112 AdapterBackplate Thumbscrew Clip Adapter Edge Connector Expansion Slot Copying the ADF File Loading Network SoftwareTroubleshooting Check List for Adapters Software Check ListGetting Help Support@ctron.com Specifications Power RequirementsSafety DimensionsChapter Making Network Connections Attaching a UTP SegmentTX+ Twisted Pair Requirements Connecting to a THIN-NET Segment BNC Interface Coax PortAttaching a Thin-Net Segment Thin-Net RequirementsConnecting to a Fiber Optic Link Segment ST Fiber Optic Connectors Fiber Optic RequirementsFiber Optic Interface Fiber Optic Ports Wire Fault/Attachment LED AUI Port AUI Connector Screws AUI Interface AUI Cable RequirementsAppendix a ADDRESS/INTERRUPT Tables Table A-1. I/O Ports of Common DevicesA-2 Index Index