Extron electronic IPL T PC1i setup guide Hardware Setup, cont’d, Connecting the Hardware

Page 10

Hardware Setup, cont’d

D

LAN connector and LEDs — An Ethernet connection can be

 

used on an ongoing basis to monitor and control the PC1 (and

 

the output device connected to it).

Wiring the Local Area Network (LAN) port

For 10Base-T (10 Mbps) networks, use a Category 3 or

 

better cable.

RJ-45 port — Plug a patch cable into this RJ-45 female socket, and connect the other end to a network switch, hub, router, or PC. (See "Wiring the Local Area Network (LAN) port," on the next page, for information on cable types to use.)

Link LED — This green LED lights

to indicate a good network connection.

LAN

RJ-45

Port

Link

LED

Activity

LED

For 100Base-T (100 Mbps) networks, use a Category 5

 

cable.

Use a straight-through cable to connect to a switch, hub, or

 

router.

Use a crossover cable to connect directly to a computer.

 

Wire the connector as shown in the tables below.

Pinouts for the two types of Ethernet cables are shown in the illustration below.

 

Activity LED — This yellow LED blinks to indicate

 

 

network activity.

E

IR port — Connect an IR emitter to pins 3 (S, for signal) and

 

4 (G, for ground) of this shared captive screw connector to

 

enable infrared remote control of the output device. To enable

 

IR control, you must load an Extron IR driver for your output

 

device to the PC1 (via Global Configurator).

F

Contact closure Input port — Connect a contact closure device

 

to pins 1 (IN, for input) and 2 (

 

, for ground) of this shared

 

 

 

 

 

captive screw connector to enable the PC1 to detect a closed

 

circuit between an input and ground.

G

Output power receptacle — Connect the power cord from an

 

output device to this three-prong female Edison (IPL T PC1) or

IEC (IPL T PC1i) power output receptacle.

Connecting the Hardware

Connect the cables to the rear panel as follows:

1.

Connect an IEC power cord from the PC1 rear panel male

 

IEC receptacle to a wall outlet. The green Power LED

 

lights and remains lit.

2.

Plug the Ethernet cable from your network into the LAN

 

port on the rear panel. The Link LED lights green.

3.

Plug the power cord of the device to be controlled into the

 

output receptacle on the back panel of the PC1.

4.

If desired, connect the output device to the RS-232 COM

 

port.

5.

If desired, connect an IR emitter to the IR port to control an

 

output device.

6.

If desired, connect a contact switch to the contact closure

 

input port.

Pins:

1 2 3 4 5 6 7 8

Side View

Insert

Twisted

Pair Wires

RJ-45 Connector

Straight-through Cable

(for connection to a switch, hub, or router)

 

End 1

 

End 2

Pin

Wire Color

Pin

Wire Color

1

white-orange

1

white-orange

2

orange

2

orange

3

white-green

3

white-green

4

blue

4

blue

5

white-blue

5

white-blue

6

green

6

green

7

white-brown

7

white-brown

8

brown

8

brown

Crossover Cable

(for direct connection to a PC)

 

End 1

 

End 2

Pin

Wire Color

Pin

Wire Color

1

white-orange

1

white-green

2

orange

2

green

3

white-green

3

white-orange

4

blue

4

blue

5

white-blue

5

white-blue

6

green

6

orange

7

white-brown

7

white-brown

8

brown

8

brown

2-4

IPL T PC1 Interface • Hardware Setup

IPL T PC1 Interface • Hardware Setup

2-5

Image 10
Contents Setup Guide Checklist IPL T PC1 and IPL T PC1iPrecautions Extron’s Warranty安全须知 中文 Table of Contents Table of Contents, cont’d IPL T PC1About this Manual About Global ConfiguratorIntroduction About the IPL T PC1Introduction, cont’d Installing Global ConfiguratorClick the Global Configurator icon System requirementsTwo IPL T PC1Front Panel Hardware SetupRear Panel Connecting the Hardware Hardware Setup, cont’dWiring the Local Area Network LAN port RS-232 port cabling Download tabWiring for IR control Wiring the contact Input portCreating a Global Configurator Project File Software SetupStep One Download device drivers Step Two Create a new project Software Setup, cont’dSelect Create a New Project Select the Auto Configure IP Address check box Step Three Add a deviceStep Five Save the new Global Configurator file Step Four Define the location of the new deviceStep Six Enter contacts Step Seven Create e-mail messagesStep Nine Assign device drivers Click Add DriverCreate a group folder for your output device functions Step Ten Set scheduled actions and e-mail deliveries Click the Apply Email/Contacts button Step Eleven Set monitored conditions Or click the Build All Configurations icon shown at right Step Twelve Build the Global Configurator fileBuilding and Uploading a GC File Step Thirteen Upload the Global Configurator file Step Fourteen Change device settings if desiredStep Fifteen Launch GlobalViewer Software Setup, cont’d Launching the GlobalViewer InterfaceHttp//12.113.184.57/nortxeindex.html This page was intentionally left blank Software Setup, cont’d
Related manuals
Manual 2 pages 39.09 Kb Manual 78 pages 34.87 Kb

IPL T PC1, IPL T PC1i specifications

The Extron Electronics IPL T PC1 i and IPL T PC1 are advanced presentation and control processors designed for optimal efficiency in various audiovisual applications. These devices serve as integral components in many professional environments, offering sophisticated capabilities for managing and automating AV systems.

Both models feature a robust, intuitive user interface that simplifies the management of complex audiovisual setups. The IPL T PC1 i and IPL T PC1 enable seamless integration with a variety of control systems, enhancing the user experience and providing streamlined operation. With their scalable design, these devices can cater to the needs of small conference rooms to large auditoriums, making them versatile solutions for diverse applications.

One standout feature of the IPL T PC1 i is its support for Extron's GUI Designer software. This powerful tool allows users to create customized graphical user interfaces tailored to specific AV systems, ensuring that control remains user-friendly and accessible. The IPL T PC1 i also supports a wide range of communication protocols, including Ethernet, RS-232, and USB, which facilitates compatibility with multiple devices and technologies.

Both models are equipped with advanced signal processing capabilities. They offer support for high-resolution video formats, ensuring that presentations and multimedia displays maintain their quality. Options for signal routing and switching further enhance the functionality of the devices, allowing for dynamic and adaptive presentations.

The IPL T PC1 i and IPL T PC1 also feature built-in scheduling and automation capabilities. Users can program specific tasks, such as turning systems on or off, adjusting volume levels, and changing input sources, at predetermined times. This feature maximizes efficiency, minimizes the need for manual intervention, and ensures that AV systems are ready when needed.

In terms of physical design, both models are compact and rack-mountable, allowing for easy installation in equipment racks or dedicated AV cabinets. They also include comprehensive diagnostic tools for troubleshooting and system monitoring, ensuring optimal performance and reliability.

Overall, the Extron Electronics IPL T PC1 i and IPL T PC1 stand out as reliable, feature-rich solutions for managing AV systems in a variety of settings, making them a popular choice among AV professionals and institutions alike. Their blend of adaptability, user interface design, and robust signal processing capabilities positions them as leaders in the AV control market.