Extron electronic MTP SW6 user manual Reference Information, Specifications

Page 29

Reference Information

Specifications

Video

Gain

Unity

Video input — see MTP Series transmitter specifications

Number/signal type

6 sets of proprietary analog signals

Connectors

6 female RJ-45

Video output — See MTP Series receiver specifications

Number/signal type

1 set of proprietary analog signals

Connectors

1 female RJ-45

Maximum resolution

1920x1200

NRefer to the user's manual for the maximum distances recommended for specific resolutions.

Audio

Number/signal type

1 set of proprietary analog signals

Connectors

1 female RJ-45

Gain

Unbalanced output: 0 dB;

 

balanced output: +6 dB

Frequency response

20 Hz to 20 kHz, ±1 dB

THD + Noise

0.15% @ 1 kHz,

 

0.3% @ 20 kHz at nominal level

S/N

>70 dB at maximum output (unweighted)

CMRR

>43 dB @ 20 Hz to 20 kHz

Audio input — see MTP Series transmitter specifications

Number/signal type

6 sets of proprietary analog signals

Connectors

6 female RJ-45

N0 dBu = 0.775 Vrms, 0 dBV = 1 Vrms, 0 dBV 2 dBu

Audio output — local

Number/signal type

1 dual mono, balanced/unbalanced

Connectors

(1) 3.5 mm captive screw connector, 5 pole

Impedance

50 ohms unbalanced, 100 ohms balanced

Gain error

±1 dB channel to channel

Maximum level (Hi-Z)

>+18 dBu, balanced or unbalanced at

 

1% THD+N

Maximum level (600 ohm)

>+15 dBm, balanced or unbalanced at

 

1% THD+N

Audio output — see MTP Series receiver specifications

Number/signal type

1 set of proprietary analog signals

Connectors

1 female RJ-45

Control/remote— switcher host control

Serial control port

1 RS-232, 9-pin female D connector

Baud rate and protocol

9600 baud, 8 data bits, 1 stop bit, no parity

Serial control pin configuration ..

2 = TX, 3 = RX, 5 = GND

Program control

Extron's control/configuration program

 

for Windows®

 

Extron's Simple Instruction Set (SIS)

Control/remote — external device (pass-through)

Serial control port

RS-232, 3.5 mm captive screw connector,

 

5 pole (uses 3 poles)

Baud rate and protocol

Up to 38400 baud, 5-8 data bits;

 

1 or 2 stop bits; odd, even, or no parity;

 

XON, XOFF, or no flow control

NProtocol is mirrored between the switcher and the receiver.

Serial control pin configuration .. 1 = TX, 2 = RX, 3 = GND

General

Recommended cable type

CAT5/5E/6 (shielded or unshielded)

External power supply

100 VAC to 240 VAC, 50/60 Hz, external;

 

to 12 VDC, 2 A, regulated

Power input requirements

12 VDC, 0.8 A

Temperature/humidity

Storage: -40 to +158 °F (-40 to +70 °C) /

 

10% to 90%, noncondensing

 

Operating: +32 to +122 °F (0 to +50 °C) /

 

10% to 90%, noncondensing

Cooling

Convection, vents on both sides

A-2 MTP SW6 • Reference Information

MTP SW6 • Reference Information A-3

Image 29
Contents MTP SW6 Extron’s Warranty PrecautionsFCC Class a Notice 安全须知 中文Table of Contents Appendix a Reference Information Table of Contents, cont’dRS-232 function About the MTP SW6 SwitcherIntroduction Transmission distance Introduction, cont’d Twisted Pair TP Cable AdvantagesMTP SW6 Introduction Introduction, cont’d MTP SW6Mounting the Switcher Installation and OperationTabletop use Rack shelf mountingFurniture mounting Installation and Operation, cont’dMTP SW6 Installation and Operation Into this 2-pole captive screw connector. See Power supply Installation and Operation, cont’d Connectors and SettingsDC power connector Plug the external 12 VDC power supply Making connections Power supply wiringTP cable termination RJ-45 ConnectorReceiver considerations OperationDelay Adjust skew adjustment control This control Switch modeSkew delay compensation Installation and Operation, cont’d Optimizing the VideoLevel/peaking setting Three Symbol definitions Remote ControlSimple Instruction Set Control Host-to-interface communicationsError responses Remote Control, cont’dTimeout Using the command/response tableLevel adjustment Command/response table for SIS commandsPeaking adjustment Input selectionRS-232 insert enable Skew adjustmentAudio/RS-232 TP input wire pair 3 and 6 configuration RemoteAudio input gain and attenuation SW6 Local audio output volumeAudio or RS-232 mute commands Lock executive modes Switch mode SW6Resets Information requests VX!AX!FX1$VmtX1#AmtX1#ExeX1#Windows-Based Program Control Installing the softwareUsing the help system Using the softwareIR 102 Infrared Remote Control Remote Control, cont’d Contact Closure Remote ControlReference Information SpecificationsReference Information, cont’d AccessoriesPart Numbers Included partsConnector Part number ConnectorsCables Enhanced Skew-Free A/V cable Part number