Extron electronic MTP SW6 user manual Skew adjustment, RS-232 insert enable, Remote

Page 22

3-

Command/response table for SIS commands (continued)

8

 

 

 

 

 

 

 

 

 

 

 

Command

ASCII Command

Response

Additional description

MTP

 

(host to unit)

 

(unit to host)

 

 

Skew adjustment

 

 

 

 

SW6

Set all skew adjustment

EX!*X%*X%*X%Iseq}

 

Set a specific skew adjustment for the TP input. X%

values for an input

E2*0*0*4Iseq}

 

IseqX!*X%*X%*X%]

values are listed in RGB order.

Example:

 

Iseq02*00*00*04]

Set input 2’s skew settings as follows:

Remote

 

 

 

 

Blue = 8 ns (delayed 8 ns).

 

 

 

 

 

Red = 0 ns

 

 

 

 

 

Green = 0 ns

Control

Increment one input's

EX!*X^+Iseq}

IseqX!*X%*X%*X%]

Increase input X!'s X^plane’s skew adjustment by 1 step

Decrement one input's

EX!*X^-Iseq}

 

IseqX!*X%*X%*X%]

Decrease input X!'s X^plane’s skew adjustment by

 

skew adjustment value

 

 

 

(2 ns).

 

skew adjustment value

 

 

 

1 step (2 ns).

 

Example:

E2*2*-Iseq}

 

Iseq02*00*00*03]

Decrease input 2’s blue skew by 2 ns to 6 ns.

 

Read input skew

EX!Iseq}

 

X%*X%*X%]

 

 

adjustment values

 

 

 

 

 

 

 

 

 

 

N X!= Input number

1 – 6

 

 

 

X%= Skew adjustment range

00 – 31 (each step = 2ns)

 

 

X^= Video plane

 

0 = red

 

 

1 = green

2 = blue

Command/response table for SIS commands (continued)

Command

ASCII Command

Response

Additional description

 

(host to unit)

(unit to host)

 

RS-232 insert enable

 

 

 

Disable the RS-232 insert

E1*0Lrpt}

Lrpt0]

Disable the RS-232 insert.

Enable the RS-232 insert

E1*1Lrpt}

Lrpt1]

Enable the RS-232 insert.

Read the RS-232 insert

E1Lrpt}

X&]

Show the status of the RS-232 insert.

status

 

 

 

Audio/RS-232 TP input (wire pair 3 and 6) configuration

NThe RS-232 insert, when enabled (E1*1Lrpt}), overrides the audio/RS-232 TP input configurations.

 

Configure input as

X!*0\

TypX!*0]

Define the audio/RS-232 input as audio, such as

 

audio

 

 

 

provided by an MTP 15HD A transmitter.

MTP

Configure input as

X!*1\

TypX!*1]

Define the audio/RS-232 input as bidirectional serial

RS-232

 

 

 

communications, such as provided by an MTP 15HD RS

 

 

 

 

transmitter.

SW6

Read TP input

X!\

X*]

Show the audio/RS-232 wire pair input definition.

configuration

 

 

 

 

 

 

 

 

 

Remote

N X&= RS-232 output insert status

0

= disabled

 

X!= Input number

1

= enabled

 

1 – 6

 

X*= Audio/RS-232 wire pair input type

0

= audio

 

Control

 

 

 

1

= RS-232

 

 

 

 

 

 

3-9

 

 

 

 

 

Remote Control, cont’d

Image 22
Contents MTP SW6 Precautions Extron’s Warranty安全须知 中文 FCC Class a NoticeTable of Contents Table of Contents, cont’d Appendix a Reference InformationIntroduction About the MTP SW6 SwitcherRS-232 function Introduction, cont’d Twisted Pair TP Cable Advantages Transmission distanceMTP SW6 Introduction MTP SW6 Introduction, cont’dTabletop use Installation and OperationMounting the Switcher Rack shelf mountingMTP SW6 Installation and Operation Installation and Operation, cont’dFurniture mounting DC power connector Plug the external 12 VDC power supply Installation and Operation, cont’d Connectors and SettingsInto this 2-pole captive screw connector. See Power supply Power supply wiring Making connectionsRJ-45 Connector TP cable terminationOperation Receiver considerationsSwitch mode Delay Adjust skew adjustment control This controlLevel/peaking setting Installation and Operation, cont’d Optimizing the VideoSkew delay compensation Three Simple Instruction Set Control Remote ControlSymbol definitions Host-to-interface communicationsTimeout Remote Control, cont’dError responses Using the command/response tablePeaking adjustment Command/response table for SIS commandsLevel adjustment Input selectionAudio/RS-232 TP input wire pair 3 and 6 configuration Skew adjustmentRS-232 insert enable RemoteAudio or RS-232 mute commands Local audio output volumeAudio input gain and attenuation SW6 Resets Switch mode SW6Lock executive modes VX!AX!FX1$VmtX1#AmtX1#ExeX1# Information requestsInstalling the software Windows-Based Program ControlUsing the software Using the help systemRemote Control, cont’d Contact Closure Remote Control IR 102 Infrared Remote ControlSpecifications Reference InformationPart Numbers AccessoriesReference Information, cont’d Included partsCables ConnectorsConnector Part number Enhanced Skew-Free A/V cable Part number