Extron electronic MTP SW6 Audio input gain and attenuation SW6, Local audio output volume

Page 23

3-

Command/response table for SIS commands (continued)

10

 

 

 

 

 

Command

ASCII Command

Response

Additional description

MTP

 

(host to unit)

(unit to host)

 

 

Audio input gain and attenuation

 

 

SW6 •

N The set gain (G) and set attenuation (g) commands are case sensitive. The increment, decrement, and read commands are not case sensitive.

Set input audio gain to

X!*X(G

InX!•AudX1)]

 

+dB value

 

 

 

Remote

Example:

1*2G

In01•Aud+02]

Set input 1 audio gain to +2 dB.

 

 

Set input audio

X!*X1!g

InX!•AudX1)]

 

 

attenuation to -dB value

 

 

 

Control

Increment gain

X!+G

InX!•AudX1)]

Increase gain by 1 dB.

Decrement gain

X!-G

InX!•AudX1)]

Decrease gain by 1 dB.

 

Example:

5+G

In05•Aud+03]

Increase audio input 5 level from +2 dB to +3 dB.

 

Example:

7-G

In07•Aud-09]

Decrease audio input 7 level from -8 dB to -9 dB.

 

Read input gain

X!G

X1)]

 

 

 

 

 

 

N X!= Input number

1 – 6

X(= Audio gain

0 – 24 (1 dB/step)

X1)= Numeric dB value

–18 to +24 (45 steps of gain or attenuation) (Default = 0 dB)

X1!= Audio attenuation

1 – 18 (1 dB/step)

Command/response table for SIS commands (continued)

 

Command

ASCII Command Response

Additional description

 

 

(host to unit)

(unit to host)

 

 

Local audio output volume

 

 

 

Set the local audio

X1@V

VolX1@]

 

 

volume to a specific

 

 

 

 

value

 

 

 

 

Example:

50v

Vol50]

Set output 1 volume to 50%.

 

Increment volume

+V

VolX1@]

Increment volume by 1%.

 

Example:

+V

Vol51]

 

 

Decrement volume

-V

VolX1@]

Decrease volume by 1%.

 

Read output volume

V

X1@]

 

 

 

 

 

MTP

Audio or RS-232 mute commands

 

 

Audio or RS-232 mute

1Z

Amt1]

Mute output audio or RS-232 (audio off).

 

SW6 •

Audio or RS-232

0Z

Amt0]

Unmute output audio or RS-232 (audio on).

unmute

 

 

 

Read audio or RS-232

Z

X1#]

1 = mute on, 0 = mute off.

Remote

mute

 

 

 

 

 

 

 

N X1@= Volume adjustment range

0 – 100

 

Control

X1#= Mute

 

0 = off

 

 

 

1 = on (muted)

 

 

 

 

 

3-11

 

 

 

 

Remote Control, cont’d

Image 23
Contents MTP SW6 Extron’s Warranty PrecautionsFCC Class a Notice 安全须知 中文Table of Contents Appendix a Reference Information Table of Contents, cont’dRS-232 function About the MTP SW6 SwitcherIntroduction Transmission distance Introduction, cont’d Twisted Pair TP Cable AdvantagesMTP SW6 Introduction Introduction, cont’d MTP SW6Rack shelf mounting Installation and OperationMounting the Switcher Tabletop useFurniture mounting Installation and Operation, cont’dMTP SW6 Installation and Operation Into this 2-pole captive screw connector. See Power supply Installation and Operation, cont’d Connectors and SettingsDC power connector Plug the external 12 VDC power supply Making connections Power supply wiringTP cable termination RJ-45 ConnectorReceiver considerations OperationDelay Adjust skew adjustment control This control Switch modeSkew delay compensation Installation and Operation, cont’d Optimizing the VideoLevel/peaking setting Three Host-to-interface communications Remote ControlSymbol definitions Simple Instruction Set ControlUsing the command/response table Remote Control, cont’dError responses TimeoutInput selection Command/response table for SIS commandsLevel adjustment Peaking adjustmentRemote Skew adjustmentRS-232 insert enable Audio/RS-232 TP input wire pair 3 and 6 configurationAudio input gain and attenuation SW6 Local audio output volumeAudio or RS-232 mute commands Lock executive modes Switch mode SW6Resets Information requests VX!AX!FX1$VmtX1#AmtX1#ExeX1#Windows-Based Program Control Installing the softwareUsing the help system Using the softwareIR 102 Infrared Remote Control Remote Control, cont’d Contact Closure Remote ControlReference Information SpecificationsIncluded parts AccessoriesReference Information, cont’d Part NumbersEnhanced Skew-Free A/V cable Part number ConnectorsConnector Part number Cables