Extron electronic CTL208CM Serial Commands, Using the help system, Communication protocols

Page 19

Serial Communications, cont’d

Buttons must be set to operate in toggle mode to assign groups.

Groups cannot be assigned to buttons that are set to operate in toggle mode and are assigned a timeout value.

11. When all of the desired programming changes are made, click the Program button at the bottom of the window to send all of the programming entries to the control panel module.

End the session by selecting a different address than the one assigned to the CTL208. This prevents the module from responding to commands meant for another unit.

12. Click Inline Model > Select Address. The Addresses window (figure 4-2) appears.

13. Click and drag on the slider or click the scroll up ( ) or down () button until an address other than the CTL208’s address is visible.

14. Click on the desired address.

15. Click Ok.

16. If necessary, reconfigure the comm port.

The communications protocols of the control panel module should match the optimum protocols of the device to be controlled.

17. If you need to change serial port settings to match the serial communication protocol of the device to be controlled, click Communications > Comm Port > Comm 1 (or the correct Comm port). The Serial Port Setup window appears (figure 4-3).

a.

Select the desired settings by clicking in the

 

appropriate radio buttons.

b.

Click Ok.

18. Click the in the upper right corner of the startup window to exit the program.

Using the help system

For information about program features, you can access the help program in the following ways:

From within the ICS100 startup window, click on the Help entry on the task bar.

From within the Button Codes window, press the F1 key.

Serial Commands

Communication protocols

The control panel module’s serial port is factory-configured to 9600 baud, no parity, no flow control, half-duplex mode.

If you change the serial protocols, communications between the computer and the control panel module are lost until the computer is updated to match the new control panel module settings.

The communications protocols of the control panel module should match the protocols of the device to be controlled.

Command and response structure

Valid commands consist of a leading delimiter, one or more characters in a command code, and an ending delimiter. The control panel module’s response to an RS-232 command also consists of a leading delimiter, a command code, and an ending delimiter.

The control panel module’s leading delimiter code is always a left bracket ( [ ). The ending delimiter code is always a right bracket ( ] ).

Example: [CPp@] — where “[“ is the leading code, “CPp@” is the command (reset the serial port to default values), and “]” is the ending code.

Addressing the unit

The control panel module must be addressed before it will accept and respond to commands. The address packet ([CC##], where ## is the 2-digit address ) routes setup information to a particular unit on a network and enables command responses. Once the control panel module is addressed, it can accept an unlimited number of commands. If a different unit is addressed, the CTL208 ignores subsequent commands until addressed again.

The factory-installed default address is 97, but this number can be changed. The control panel module can also take commands after receiving a broadcast address of 00, but it will not send responses. Broadcast is for multiple units on an RS-485 serial line in half duplex mode.

After you are finished programming the control panel module, always terminate the session by sending an address packet to another unit with a different address. This prevents the module from responding to commands meant for another unit.

4-8

CTL208CM Control Panel Module • Serial Communications

CTL208CM Control Panel Module • Serial Communications

4-9

Image 19
Contents CTL208CM FCC Class a Notice Extron’s WarrantyCTL208CM Control Panel Module Quick Start Guide QS-1 Quick Start Guide CTL208CMTable of Contents Introduction Table of Contents, cont’dIntroductionroduction, cont’d About the CTL208CM FeaturesCTL208CM Control Panel Module Introduction Introduction, cont’d InstallationCTL208CM Control Panel Module Installation Installationtal ation, cont’d Installation OverviewCTL208CM Wall Mounting Site PreparationDevice Configuration Installation, cont’dRear Panel Setup Installation, cont’d Wall MountingCaptive screw power connector Power the control panel 10 CTL208CM Control Panel Module InstallationOperation 12 CTL208CM Control Panel Module InstallationOperationration, cont’d Button Modes Send Programmed CommandsCTL208CM Control Panel Module Operation Serial Communications Factory ResetOperation, cont’d System requirements Installing the softwareSerialCommunicationsunications,cont’d ICS100 Windows Control ProgramSerial Communications, cont’d Using the software to program the CTL208CMToggle Mode Timeout window Communication protocols Serial CommandsUsing the help system Command and response structureControl panel module responses Using the command/response table10 CTL208CM Control Panel Module Serial Communications 12 CTL208CM Control Panel Module Serial Communications Command/response table for programming the CTL208Command Additional description Response14 CTL208CM Control Panel Module Serial Communications Command Ascii Command Response Additional descriptionButton mode programming Button timeout programmingAAppendix Reference InformationParts List ReferenceInformation,cont’d SpecificationsWall mounting harware Reference Information, cont’d
Related manuals
Manual 1 pages 28.04 Kb

CTL208CM specifications

The Extron CTL 208 CM is a sophisticated control system designed for seamless integration and management of AV systems in various environments, such as educational institutions, corporate spaces, and any setting requiring robust audiovisual control. Known for its user-friendly interface and advanced features, the CTL 208 CM stands out in its category.

One of the primary features of the CTL 208 CM is its ability to control multiple AV devices through a single platform. This centralized control facilitates ease of operation for users, allowing them to manage projectors, displays, sound systems, and other devices without the need to juggle multiple remotes or interfaces. This is particularly beneficial in environments where educators or presenters need to focus on delivering their content without getting bogged down by technicalities.

The CTL 208 CM is equipped with Extron’s proprietary technologies, which enhance its performance and reliability. Notable among these is the Extron Control App, which allows users to create custom controls via a tablet or smartphone. This not only streamlines the user experience but also enables personalized settings, ensuring users can quickly access the devices they need.

Additionally, the CTL 208 CM features customizable button layouts and a graphic interface that simplifies operation, regardless of the user's technical proficiency. This flexibility is crucial in environments where users may vary significantly in their comfort level with technology.

The system's advanced communication capabilities enable it to integrate seamlessly with a variety of third-party devices, expanding its functionality and compatibility. This open architecture design supports popular protocols such as RS-232, IP control, and infrared, allowing users to implement it alongside existing infrastructures effectively.

Moreover, the CTL 208 CM boasts a scalable architecture, making it suitable for small to large installations. Users can easily expand their control system as their needs evolve without requiring a complete overhaul of their existing setup.

In summary, the Extron CTL 208 CM is a powerful control solution that combines ease of use with extensive functionality. Its advanced technologies and features position it as an ideal choice for anyone seeking a reliable and versatile AV control system. With its ability to simplify AV management and enhance user engagement, the CTL 208 CM is a valuable asset for modern audiovisual environments.