Extron electronic CTL208CM Control panel module responses, Using the command/response table

Page 20

Serial Communications, cont’d

Control panel module responses

When a command is valid, the module performs the command and sends the following response:

[R0 {address} {echo of the command sent}]

When a command is invalid, either because the command is not recognized or contains invalid parameters, the module sends the following response:

[R1 {address} {echo of the command sent}]

Using the command/response table

The command/response table begins on page 4-13. Upper or lower case letters are acceptable in the command field. The table below shows the hexadecimal equivalent of each ASCII command.

ASCII to HEX Conversion Table

 

Symbols

=

Line feed

X1 =

Address number 00 - 98 (00 addresses all units but individual units do

not respond, 97 is the factory-installed default).

The very first command that you send to the control panel module must be the connect, [CC X1 ], command, where X1 is the module’s address. The control panel module will not accept other commands or respond until it has been addressed.

The very last command that you send to the control panel module should be the connect, [CC X1 ], command, where X1 is a different address. This prevents the control panel module from accepting and responding to commands for other devices.

X2 = Button number and string (primary or secondary) (figure 4-8)

Buttons 1 and 5 are closest to the top of the CTL208. Orient the CTL208 so that the text on the rear of the unit is right-side up to determine the top of the module.

Symbols, defined starting on page 4-11, are used throughout the table to represent variables in the command/response fields. Command and response examples are shown throughout the table.

Button

Button

number

number

1

5

2

6

3

7

4

8

Figure 4-8 — Button numbers

X2 s must be 2-digit numbers.

X2 # Button/string

X2 # Button/string

01 = 1/primary

11 = 1/secondary

02 = 2/primary

12 = 2/secondary

03 = 3/primary

13 = 3/secondary

04 = 4/primary

14 = 4/secondary

05 = 5/primary

15 = 5/secondary

06 = 6/primary

16 = 6/secondary

07 = 7/primary

17 = 7/secondary

08 = 8/primary

18 = 8/secondary

X3 =

ASCII button code

Up to 128 alphanumeric characters.

 

 

If you need to use the bracket delimiters in a stored

 

 

ASCII command, you need to use the insert

 

 

brackets feature. Under this feature, one character

 

 

replaces the left bracket ( [ ) and another character

 

 

replaces the right bracket ( ] ). The default values

 

 

are a single quote mark ( ‘ ) in place of the left

 

 

bracket and a double quote ( “ ) in place of the right

 

 

bracket. The CTL208 replaces the characters with

 

 

the bracket delimiters in the stored ASCII or hex

 

 

command string.

X4 =

Bracket position

1 = left bracket, 2 = right bracket.

4-10 CTL208CM Control Panel Module • Serial Communications

CTL208CM Control Panel Module • Serial Communications 4-11

Image 20
Contents CTL208CM Extron’s Warranty FCC Class a NoticeQuick Start Guide CTL208CM CTL208CM Control Panel Module Quick Start Guide QS-1Table of Contents Table of Contents, cont’d IntroductionCTL208CM Control Panel Module Introduction FeaturesIntroductionroduction, cont’d About the CTL208CM Installation Introduction, cont’dInstallationtal ation, cont’d Installation Overview CTL208CM Control Panel Module InstallationWall Mounting Site Preparation CTL208CMInstallation, cont’d Device ConfigurationInstallation, cont’d Wall Mounting Rear Panel Setup10 CTL208CM Control Panel Module Installation Captive screw power connector Power the control panel12 CTL208CM Control Panel Module Installation OperationCTL208CM Control Panel Module Operation Send Programmed CommandsOperationration, cont’d Button Modes Operation, cont’d Factory ResetSerial Communications Installing the software SerialCommunicationsunications,cont’dICS100 Windows Control Program System requirementsUsing the software to program the CTL208CM Serial Communications, cont’dToggle Mode Timeout window Serial Commands Using the help systemCommand and response structure Communication protocols10 CTL208CM Control Panel Module Serial Communications Using the command/response tableControl panel module responses Command/response table for programming the CTL208 CommandAdditional description Response 12 CTL208CM Control Panel Module Serial CommunicationsCommand Ascii Command Response Additional description Button mode programmingButton timeout programming 14 CTL208CM Control Panel Module Serial CommunicationsReference Information AAppendixReferenceInformation,cont’d Specifications Parts ListReference Information, cont’d Wall mounting harware
Related manuals
Manual 1 pages 28.04 Kb

CTL208CM specifications

The Extron CTL 208 CM is a sophisticated control system designed for seamless integration and management of AV systems in various environments, such as educational institutions, corporate spaces, and any setting requiring robust audiovisual control. Known for its user-friendly interface and advanced features, the CTL 208 CM stands out in its category.

One of the primary features of the CTL 208 CM is its ability to control multiple AV devices through a single platform. This centralized control facilitates ease of operation for users, allowing them to manage projectors, displays, sound systems, and other devices without the need to juggle multiple remotes or interfaces. This is particularly beneficial in environments where educators or presenters need to focus on delivering their content without getting bogged down by technicalities.

The CTL 208 CM is equipped with Extron’s proprietary technologies, which enhance its performance and reliability. Notable among these is the Extron Control App, which allows users to create custom controls via a tablet or smartphone. This not only streamlines the user experience but also enables personalized settings, ensuring users can quickly access the devices they need.

Additionally, the CTL 208 CM features customizable button layouts and a graphic interface that simplifies operation, regardless of the user's technical proficiency. This flexibility is crucial in environments where users may vary significantly in their comfort level with technology.

The system's advanced communication capabilities enable it to integrate seamlessly with a variety of third-party devices, expanding its functionality and compatibility. This open architecture design supports popular protocols such as RS-232, IP control, and infrared, allowing users to implement it alongside existing infrastructures effectively.

Moreover, the CTL 208 CM boasts a scalable architecture, making it suitable for small to large installations. Users can easily expand their control system as their needs evolve without requiring a complete overhaul of their existing setup.

In summary, the Extron CTL 208 CM is a powerful control solution that combines ease of use with extensive functionality. Its advanced technologies and features position it as an ideal choice for anyone seeking a reliable and versatile AV control system. With its ability to simplify AV management and enhance user engagement, the CTL 208 CM is a valuable asset for modern audiovisual environments.