Tripp Lite SU5000RT4U Mounting 4-Post Rackmount, Mounting 2-Post Rackmount Mounting Tower

Page 5

Mounting

Mounting (4-Post Rackmount)

The UPS includes rackmount rails for 4-post rackmounting. The user must determine the fitness of hardware and procedures before mounting. If hardware and procedures are not suitable for your application, contact the manufacturer of your rack or rack enclosure. The procedures described in this manual are for common rack and rack enclosure types and may not be appropriate for all applications.

WARNING! The UPS system is extremely heavy. Use caution when lifting and mounting. User must properly stabilize the UPS when lifting and mounting.

1Connect the two segments of each shelf using the included attached screws and wing nuts. Leave the screws slightly loose so that the shelves can be adjusted in the next step.

2Adjust each shelf to fit your rack, then mount them in the lowest available space of your rack with the screws, nuts and washers provided. Note that the support ledges should face inward. Tighten the wingnuts that connect the shelf segments.

3Attach mounting ears to the front mounting holes of your UPS using the screws provided. The ears should face forward.

4Using one or more assistants, lift your UPS and slide it onto the mounting shelves. Attach your UPS to the rack by passing screws, nuts and washers (user- provided) through its mounting ears and into the rack rails.

1

3

2

4

Mounting (2-Post Rackmount)

If you mount this UPS model in 2-post racks, it requires the addition of a Tripp Lite 2-Post Rackmount Installation Kit (model: 2POSTRMKITWM, sold separately). See Installation Kit owner's manual for installation procedure.

Mounting (Tower)

Mount the UPS system in an upright, tower position using 2-9USTAND base stands (optional). The user must determine the fitness of hardware and procedures before mounting.

WARNING! The UPS system is extremely heavy. Use caution when lifting and mounting. User must properly stabilize the UPS when lifting and mounting.

1Adjust the stands to a width of 6.93 inches (176 mm) for a UPS. Adjust the stands to a width of 12.07 inches (306.5

mm)for a UPS and an external battery

module. Align the stands approximately 10 inches (254 mm) apart. Have one or more assistants help you place the UPS 1 on its side in the stands. Place the UPS

so that its control panel is on top and facing outward.

2Rotate the UPS's control panel to view it easier while the UPS is tower mounted. Insert a small screwdriver, or other tool, in the slots on either side of the control panel. Pop the panel out; rotate it; and pop the panel back into place.

1 Power Module 6.93" (176 mm)

1 Power Module +

1 Battery Module

12.07" (306.5 mm)

1

 

BYPASS

O/P

 

AC/DC

DC/AC

I/P

 

 

BATTERY

OFF

 

SELECT

 

 

 

 

SETUP

ON

MUTE

 

2

 

5

Image 5
Contents Registration Español FrançaisImportant Safety Warnings Front Panel Controls Features Mounting 2-Post Rackmount Mounting Tower Mounting 4-Post RackmountTurn the UPS on Plug your UPSs line cord into an electrical outletPlug your equipment into your UPS EPO Port Connection USB and RS-232 Serial Communication ConnectionUPS Power/Battery Module Removal Manual Bypass Operation for UPS maintenance or replacementHigh Voltage Risk of electrical shock High Voltage WarningsFailed Self-Test OperationStartup Self-Test Normal Operation On Battery AlarmAdditional Self-Test Output Voltage SelectionBypass Messages Overload MessagesOP2 Shortcircuit Shutdown MessagesStorage ServiceWarranty Registration WarrantyEnglish Français Manual del propietarioAdvertencias de seguridad importantes Controles del panel frontal Características continuación Montaje en torre Montaje montaje en bastidor de 4 postesMontaje montaje en bastidor de 2 postes Encienda el UPS Precauciones para Instalar el Cableado Eléctrico FijoConecte sus equipos en el UPS Conexión de puerto EPO Conexión de comunicaciones USB y serie RS-232Conexión de baterías externas Inserción de tarjeta interna SNMP/WEBRetiro del módulo de potencia/batería del UPS Operación de bypass manual mantenimiento o reemplazo del UPS¡Alto voltaje Advertencias de alto voltaje¡Alto voltaje ¡Riesgo de choque eléctrico Fallo durante la auto-prueba OperaciónAuto-prueba de arranque Operación normal Alarma On Battery Con bateríaAuto-Prueba Adicional Selección del Voltaje de SalidaMensajes de Bypass Mensajes de sobrecargaMensajes de apagado Servicio AlmacenamientoCumplimiento de las normas Números de identificación Aviso de FCC sobre interferencia de radio /TVEnglish Español Manuel du propriétaireImportantes mises en garde de sécurité Commandes du panneau avant Caractéristiques suite Montage Tour Montage sur bâti à quatre montantsMontage sur bâti à 2 poteaux Mises en garde concernant le câblage Brancher le cordon de lUPS dans une prise électriqueConnecter votre équipement à lUPS Mettre lUPS en marchePort série de communication USB et RS-232 Connexions optionnellesConnexion au port EPO Connexion de batterie externeEnlèvement du module alimentation/batterie de lUPS Mise en Garde Haute tension Risque de choc électrique Mises en Garde Haute tensionÉchec de lautotest FonctionnementAutotest de démarrage Fonctionnement normal Alarme en mode batterieFonctionnement suite Autre auto-test Sélection de la tension de sortieMessages de Bypass Messages de surchargeMessages sarrêt Garantie Limitée DE 2 ANS Entreposage200705052
Related manuals
Manual 52 pages 59.76 Kb

SU5000RT4U, SU6000RT4U, SU8000RT4U specifications

Tripp Lite is a renowned name in the realm of power protection solutions, and their line of uninterruptible power supplies (UPS) stands out for providing superior performance and advanced features. The Tripp Lite SU6000RT4U, SU5000RT4U, and SU8000RT4U are all remarkable options designed for various applications, ensuring consistent power delivery and robust protection against electrical disturbances.

The SU6000RT4U is a 6000VA/5400W UPS system that offers exceptional reliability to safeguard your critical equipment. It features a dual-conversion online design, which guarantees a steady output voltage regardless of fluctuations in input power. The hot-swappable batteries allow for uninterrupted power, ensuring that maintenance can occur without downtime. The graphical LCD display provides real-time information about UPS status, input/output voltage, and battery condition, enabling users to monitor performance effortlessly.

Next in line, the SU5000RT4U offers a 5000VA/4500W capacity and similar technological advancements. This model is engineered to support high-sensitive equipment, making it perfect for data centers, networking devices, and other critical applications. It includes advanced surge protection, ensuring that any spikes in electricity do not cause damage to connected devices. Like the SU6000RT4U, it also employs a dual-conversion design for superior power quality.

The SU8000RT4U is an impressive 8000VA/7200W UPS that caters to demanding applications. In addition to the features found in the smaller models, it boasts an extensive runtime, allowing it to sustain operations during prolonged power outages. This model also supports advanced management options, such as SNMP networking capabilities, which grants users the ability to monitor and manage the UPS remotely via any networked device. The battery management technology extends battery life and enhances performance, making it a standout choice for high-efficiency environments.

All three Tripp Lite UPS units are designed with foolproof safety measures, including automatic voltage regulation, isolating transformers, and thermal protection to promote longevity and reliability. Built with a rugged metal housing, they ensure durability in a variety of conditions. Compact and rack-mountable, these UPS systems fit seamlessly into data racks or server environments. With their robust features, the SU6000RT4U, SU5000RT4U, and SU8000RT4U ensure that your valuable equipment is always protected from the unpredictability of power supply issues.