Features (continued)

Rear Panel Features (Power/Battery Module and Detachable PDU Together)

5

9

5 6

8

9

7

10

10

11

 

SU6000RT4U Shown (Rear View)

12

 

 

10

 

 

Power/Battery Module: This self-contained unit houses the UPS system's power and control components as well as its internal batteries.

Independent, Detachable Power Distribution Unit (PDU): This self-contained unit houses the UPS system's input and output components along with a bypass switch. When the switch is set to bypass, the PDU can be completely removed from the power/battery module for routine power/battery module maintenance without disrupting power to connected loads. While this switch is set to BYPASS, connected equipment will receive unfiltered AC mains power, but the equipment will not receive battery power in the event of a blackout. An optional hardwire detachable PDU is also available separately from Tripp Lite. Contact Tripp Lite for details. Note: The rotary bypass switch should only be operated while the UPS is in BYPASS Mode. (See section “Manual Bypass Operation” on page 8 for details.)

External Battery Connector: Although the UPS includes a robust set of internal batteries, you may want to use this connector to attach one or more optional external battery packs (available separately from Tripp Lite) to the UPS for extended runtime. Check to ensure that the external batteries you are connecting match the voltage listed on your UPS's battery connector. Adding external batteries will increase recharge time as well as runtime. See the battery pack owner's manual for complete installation instructions. Make sure cables are fully inserted into their connectors. Small sparks may result during battery connection; this is normal. Do not connect or disconnect battery packs when the UPS is running on battery power.

Battery Charge Level Switch (Select Models Only): Controls the UPS system's battery charge rate. If you connect any external batteries, set the Battery Charge Level Switch to the right (labeled “EXTERNAL BATTERIES”). This will increase your UPS's charger output so the additional batteries charge faster. CAUTION! DO NOT set the Battery Charge Level Switch to the right (labeled “EXTERNAL BATTERIES”) without an external battery connected. There is a risk of damaging the UPS's internal battery system.

Ventilation Fans: These fans cool and ventilate the inside of the UPS.

USB and RS-232 Communication Ports: These USB and female RS-232 DB9 serial ports may be used to connect your UPS to a workstation or server. They are used with Tripp Lite software and the included USB or serial cable to monitor and manage the UPS remotely over a network and to automatically save open files and shut down equipment during a blackout. See “Optional Connection” for details.

EPO (Emergency Power Off) Port: This port may be used to connect the power module to a contact closure switch to enable emergency power off. See “Optional Connection” section for details.

Accessory Slot: Remove the slot's cover to install an optional internal SNMP/Web accessory card (Model: SNMPWEBCARD) to enable remote UPS monitoring and control via SNMP, Web or telnet. Visit Tripp Lite on the Web (www.tripplite.com) to learn about available SNMP, network management and connectivity products that may be installed in this slot.

AC Output Breakers: These breakers control output power from the independent, detachable PDU.

AC Receptacles: Your UPS features 15-, 20- and 30-amp AC outlets. These output receptacles provide your connected equipment with AC line power during normal operation and battery power during blackouts and severe brownouts and overvoltages. The UPS protects equipment connected to these receptacles against damaging surges and line noise. If you have a serial or USB connection to your UPS, you can remotely reboot connected equipment by turning the receptacles OFF and ON using Tripp Lite's PowerAlert Software. See software instructions for details.

AC Input: Connects the UPS system to a utility wall outlet. Your UPS must be connected to a dedicated circuit of sufficient amperage.

Note: Model SU8000RT4U has a hardwire input instead of an input cord/plug

Maintenance Bypass Switch: This switch allows qualified service personnel to remove the detachable PDU from the power/battery module for routine maintenance without disrupting power to connected loads. While this switch is set to BYPASS, connected equipment will receive filtered AC mains power, but the equipment will not receive battery power in the event of a blackout. See “Manual Bypass Operation” section for complete bypass procedure.

WARNING! For qualified service personnel only. Failure to follow the bypass procedure completely (see Manual Bypass Operation section) will not adequately power down the UPS power/battery module, resulting in the continued risk of death or injury from potential contact with high voltage.

4

201102170 932611.indd 4

3/30/2011 10:22:10 AM

Image 4
Contents Español Français Important Safety Warnings Front Panel Controls Features Mounting 4-Post Rackmount Mounting 2-Post Rackmount Mounting TowerPlug your equipment into your UPS Plug your UPSs line cord into an electrical outletTurn the UPS on USB and RS-232 Serial Communication Connection EPO Port ConnectionExternal Battery Connection Internal SNMP/WEB Card Insertion Manual Bypass Operation for UPS maintenance or replacement UPS Power/Battery Module RemovalHigh Voltage Warnings High Voltage Risk of electrical shockStartup Self-Test OperationFailed Self-Test On Battery Alarm Normal OperationConfiguration Menu Additional Self-TestOverload Messages Bypass MessagesShutdown Messages OP2 ShortcircuitService StorageWarranty Warranty RegistrationManual del propietario Advertencias de seguridad importantes Controles del panel frontal Características continuación Montaje montaje en bastidor de 2 postes Montaje montaje en bastidor de 4 postesMontaje en torre Conecte sus equipos en el UPS Precauciones para Instalar el Cableado Eléctrico FijoEncienda el UPS Conexión de comunicaciones USB y serie RS-232 Conexión de puerto EPOConexión de baterías externas Conexión opcional continuaciónInserción de tarjeta interna SNMP/WEB Operación de bypass manual mantenimiento o reemplazo del UPS Retiro del módulo de potencia/batería del UPSAdvertencias de alto voltaje ¡Alto voltaje ¡Riesgo de choque eléctricoAuto-prueba de arranque OperaciónFallo durante la auto-prueba Alarma On Battery Con batería Operación normalMenú de Configuración Auto-Prueba AdicionalMensajes de sobrecarga Mensajes de BypassMensajes de apagado Almacenamiento ServicioGarantía Limitada DE 2 Años Manuel du propriétaire Importantes mises en garde de sécurité Commandes du panneau avant CaractéristiquesCaractéristiques suite Montage sur bâti à 2 poteaux Montage sur bâti à quatre montantsMontage Tour Brancher le cordon de lUPS dans une prise électrique Mises en garde concernant le câblageConnecter votre équipement à lUPS Mettre lUPS en marchePort série de communication USB et RS-232 Connexions optionnellesConnexion au port EPO Connexion de batterie externe Connexions optionnelles suiteInsertion de la carte interne SNMP/WEB Enlèvement du module alimentation/batterie de lUPS Mise EN GARDE! Haute tension! Risque de choc électrique Mise en Garde Haute tension Risque de choc électriqueAutotest de démarrage FonctionnementÉchec de lautotest Fonctionnement suite Alarme en mode batterieFonctionnement normal Menu de configuration Autre auto-testMessages de surcharge Messages de BypassMessages sarrêt Entreposage Garantie Limitée DE 2 ANS 201102170 93-2611FR
Related manuals
Manual 48 pages 31.93 Kb

SU5000RT4U, SU6000RT4U, SU8000RT4U specifications

Tripp Lite is a renowned name in the realm of power protection solutions, and their line of uninterruptible power supplies (UPS) stands out for providing superior performance and advanced features. The Tripp Lite SU6000RT4U, SU5000RT4U, and SU8000RT4U are all remarkable options designed for various applications, ensuring consistent power delivery and robust protection against electrical disturbances.

The SU6000RT4U is a 6000VA/5400W UPS system that offers exceptional reliability to safeguard your critical equipment. It features a dual-conversion online design, which guarantees a steady output voltage regardless of fluctuations in input power. The hot-swappable batteries allow for uninterrupted power, ensuring that maintenance can occur without downtime. The graphical LCD display provides real-time information about UPS status, input/output voltage, and battery condition, enabling users to monitor performance effortlessly.

Next in line, the SU5000RT4U offers a 5000VA/4500W capacity and similar technological advancements. This model is engineered to support high-sensitive equipment, making it perfect for data centers, networking devices, and other critical applications. It includes advanced surge protection, ensuring that any spikes in electricity do not cause damage to connected devices. Like the SU6000RT4U, it also employs a dual-conversion design for superior power quality.

The SU8000RT4U is an impressive 8000VA/7200W UPS that caters to demanding applications. In addition to the features found in the smaller models, it boasts an extensive runtime, allowing it to sustain operations during prolonged power outages. This model also supports advanced management options, such as SNMP networking capabilities, which grants users the ability to monitor and manage the UPS remotely via any networked device. The battery management technology extends battery life and enhances performance, making it a standout choice for high-efficiency environments.

All three Tripp Lite UPS units are designed with foolproof safety measures, including automatic voltage regulation, isolating transformers, and thermal protection to promote longevity and reliability. Built with a rugged metal housing, they ensure durability in a variety of conditions. Compact and rack-mountable, these UPS systems fit seamlessly into data racks or server environments. With their robust features, the SU6000RT4U, SU5000RT4U, and SU8000RT4U ensure that your valuable equipment is always protected from the unpredictability of power supply issues.