Tripp Lite SU3000XL Important Safety Instructions, Plug your UPS into an electrical outlet

Page 2

Important Safety Instructions

SAVE THESE INSTRUCTIONS

This manual contains instructions and warnings that should be followed during the installation, operation and storage of all Tripp Lite UPS Systems. Failure to heed these warnings will void your warranty.

UPS Location Warnings

Install your UPS indoors, away from excess moisture or heat, conductive contaminants, dust or direct sunlight.

For best performance, keep the indoor temperature between between 32º F and 104º F (0º C and 40º C).

Leave adequate space around all sides of the UPS for proper ventilation.

UPS Connection Warnings

Connect your UPS directly to a properly grounded AC power outlet. Do not plug the UPS into itself; this will damage the UPS.

Do not modify the UPS's plug, and do not use an adapter that would eliminate the UPS’s ground connection.

Do not use extension cords to connect the UPS to an AC outlet. Your warranty will be voided if anything other than Tripp Lite surge suppressors are used to connect your UPS to an outlet.

If the UPS receives power from a motor-powered AC generator, the generator must provide clean, filtered, computer-grade output.

Equipment Connection Warnings

Quick Installation

Connection and Start-Up

1Plug your UPS into an electrical outlet.

Plug the UPS directly into a properly ground- ed, 3-wire, AC outlet that does not share a cir- cuit with a heavy electrical load (such as an air conditioner, refrigerator, etc.). The outlet must have an amp rating equal to or greater than your UPS’s input breaker rating (see Specifications).

Note: Once your UPS is plugged in, the fan and all Indicator Lights will turn ON. The “LINE” and “LOAD ACTIVE METER” LEDs will illuminate and the UPS will beep to indicate normal operation. However, power is not supplied to your UPS’s AC outlets until the UPS is turned on.

2Plug your equipment into your UPS.

Your UPS is designed to support computer equipment only. You will overload your UPS if you connect devices with high power demands such as household appliances or laser printers to your UPS's outlets.

 

SU1000XL Plug

1

(NEMA 5-15) shown

2

SU2200XL shown

Do not use Tripp Lite UPS Systems for life support applications in which a malfunction or failure of a Tripp Lite UPS System could cause failure or significantly alter the performance of a life-support device.

Battery Warnings

Your UPS does not require routine maintenance. There are no user-serviceable parts inside. Do not open your UPS for any reason.

Since batteries present a risk of electrical shock and burn from high short-circuit current, observe proper precautions. Unplug and turn off the UPS before performing battery replacement. Use tools with insulated handles, and replace the existing batteries with the same number and type of new batteries (sealed lead-acid). Do not open the batteries. Do not short or bridge the battery terminals with any object. Tripp Lite offers a complete line of UPS System Replacement Battery Cartridges (R.B.C.). Visit Tripp Lite on the Web at www.tripplite.com/support/battery/index.cfm to locate the specific replacement battery for your UPS.

The UPS batteries are recyclable. Refer to local codes for disposal requirements, or in the USA only call 1-800-SAV-LEAD or 1-800-8-BATTERY (1-800-8-228-8379) or visit www.rbrc.com for recycling information. Do not dispose of the batteries in a fire.

Do not operate your UPS without batteries.

2

3 Turn your UPS ON:

• Press the “ON/TEST” Switch

• Hold it for several seconds until you hear a beep

• Release it

The “ON LINE” LED will now light, and your

 

 

UPS will begin providing power to its AC

 

SU1000XL

outlets.

 

3

shown

Note: If this is the first time you have plugged in your UPS, or if your UPS has been in storage for a prolonged period, it will need to charge its batteries for 2-4 hours before it can support connected equip- ment in the event of a power failure.

3

Image 2
Contents SmartOnline Plug your equipment into your UPS Important Safety InstructionsPlug your UPS into an electrical outlet Turn your UPS onFront Panel Switches ImportantBasicOperationSafety InstructionsExternal Battery Pack Connection Front Panel Indicator LightsRear Panel Communications Check the utility line for wiring problemsRestart the UPS. If the problem persists Service This indicates that utility power is too highProperly. Restart the UPS. If the problem Or low for the UPS to operate in BypassManual del usuario Enchufe su equipo al sistema UPS Importantes instrucciones de seguridadConecte su UPS en un tomacorriente Encienda su sistema UPS onInterruptores del panel frontal Conexión de puerto serialConexión del paquete de baterías externas Luces indicadoras del panel frontalPanel posterior Operación básica continuaciónLuces indicadoras del panel frontal continuación Comunicaciones Condición Error de EepromPanel posterior continuación Condición Reemplazar bateríaLocalización de fallas continuación Almacenamiento y servicio continuaciónGuide de lutilisateur Importantes consignes de sécuritéInstallation suite Commutateurs du panneau avant OrtantImExploitationtySafde baseInstructionsExploitation de base suite Voyants du panneau avantPanneau arrière Panneau arrière suiteDépannage suite Entreposage Entretien

SU3000XL, SU1000XL, SU2200XL specifications

Tripp Lite is known for its reliable power protection solutions, and the SU3000XL, SU2200XL, and SU1000XL series of uninterruptible power supplies (UPS) exemplify this commitment. Each model is designed to provide high-performance power protection for servers, networking equipment, and critical electronic devices, ensuring that operational continuity is maintained even during power interruptions.

The SU3000XL is a robust solution offering 3000VA / 2400W capacity. It features sine wave output, which is essential for the safe functioning of sensitive electronics. With multiple output options, including a variety of outlets, the SU3000XL supports a wide range of devices. This model also incorporates advanced technologies like Automatic Voltage Regulation (AVR), which stabilizes voltage levels, ensuring connected devices receive clean and consistent power. Additionally, the UPS is equipped with an LCD display, providing real-time monitoring of power conditions, battery status, and load levels.

The SU2200XL presents a versatile 2200VA / 1980W capacity. Similar to the SU3000XL, it offers sine wave output and AVR technology. Its compact design makes it suitable for smaller setups without compromising power availability. The SU2200XL is an ideal choice for businesses or home environments that require dependable backup power for vital systems while maintaining energy efficiency. Built-in USB and serial connectivity allow users to integrate with management software, enabling seamless power management and monitoring.

For environments with lower power needs, the SU1000XL delivers a capacity of 1000VA / 800W. This model is particularly well-suited for desktops, workstations, and smaller network devices. Despite its smaller capacity, the SU1000XL does not skimp on features. It also includes sine wave output and AVR technology, providing the essential power protection that Tripp Lite is known for. An easy-to-read LED display presents vital information at a glance, making it user-friendly.

All three models boast hot-swappable batteries, allowing for easy maintenance without downtime. Furthermore, they come with a variety of safety features, including surge protection and short circuit protection, enhancing their reliability. With a focus on durability, Tripp Lite’s UPS systems are built to last, backed by a solid warranty and customer support. Overall, the SU3000XL, SU2200XL, and SU1000XL ensure that users can trust their power sources, no matter the requirements.