Tripp Lite SMX & OMNIX owner manual Indicator Lights, Power LED

Page 7

Basic Operation continued

Indicator Lights

All Indicator Light descriptions apply when the UPS is plugged into an AC outlet and turned on.

“POWER” LED

For SMX Models Only: this green LED lights continuously when the UPS is ON and supplying connected equipment with AC power from a utility source. The LED flashes and an alarm sounds (4 short beeps followed by a pause) to indicate the UPS is operating from its inter- nal batteries during a blackout or severe brownout. If the blackout or severe brownout is prolonged, you should save files and shut down your equipment since internal battery power will eventually be deplet- ed. See “BATTERY CHARGE” LED description below.

For OMNIX Models Only: this green light will turn ON whenever your UPS is receiving normal AC line power. It will flash while the UPS is in CHARGE ONLY mode to indicate that the UPS will not provide battery backup during a blackout or brownout.

“VOLTAGE CORRECTION” LED (SMX Models Only): this green LED lights continuously whenever the UPS is automatically correcting high or low AC voltage on the utility line without the assis- tance of battery power. The UPS will also emit a slight clicking noise. These are normal, automatic operations of the UPS. No action is required on your part.

“OUTPUT LOAD LEVEL” LED:

For SMX Models Only: this multicolored LED indicates the approx- imate electrical load of equipment connected to the UPS's AC outlets. It will turn from green (light load) to yellow (medium load) to red (overload). If the LED is red (either illuminated continuously or flash- ing), clear the overload immediately by unplugging some of your equipment from the outlets until the LED changes from red to yellow (or green) and the alarm is no longer sounding. CAUTION! Any over- load that is not corrected by the user immediately may cause the UPS to shut down and cease supplying output power in the event of a black- out or severe brownout.

For OMNIX Models Only: this red light will turn ON continuously when the UPS is providing power from battery or after the UPS runs a self-test to indicate that the UPS's inverter is overloaded. If it lights up, immediately remove some of the equipment connected to the UPS and run a self-test. CAUTION! Any overload that is not corrected by the user immediately may cause the UPS to shut down and cease sup- plying output power in the event of a blackout or severe brownout.

7

Image 7
Contents Medical Grade UPS Systems SMX & OmnixUPS Location Warnings Important Safety InstructionsUPS on Tel/DSL Protection Quick Installation optionalSerial Communications USB CommunicationsButtons For SMX Models Only-POWER ButtonFor Omnix Models Only-UPS/STANDBY Button For All Models-MUTE/TEST Button Power LED Indicator LightsBattery Charge / Battery Power LED Other UPS Features Storage Regulatory Compliance Identification Numbers ServiceSistemas UPS grado medico Manual de operaciónAdvertencias sobre las baterías Importantes instrucciones de seguridadAdvertencias sobre la colocación del UPS Advertencias sobre la conexión del equipoPara todos los modelos-Conecte su equipo en el UPS Sólo para modelos OmnixSólo para modelos SMX Encienda el UPS Protección para módem / fax Instalación rápida optativaComunicaciones en serie Comunicaciones USBSólo para modelos OMNIX-Botón UPS/STANDBY UPS/Reserva Botones Sólo para modelos SMX Botón Power AlimentaciónPara todos los modelos-Botón MUTE/TEST Silencio/Prueba Operación básica continuaciónLuces indicadoras Otras características del sistema UPS Norm Delay Servicio AlmacenamientoNota sobre el rotulado Declaraciones Regulatorias y de SeguridadSystèmes UPS de classe médicale Guide de lutilisateurMises en garde relatives au raccord de léquipement Mises en garde relatives à lemplacement du système UPSImportantes consignes de sécurité Mises en garde relatives au raccord du système UPSPour tous les modèles-Branchez votre équipement dans lUPS Pour les modèles Omnix uniquementPour les modèles SMX uniquement Mettez en marche lUPS on Protection du modem télécopieur Installation rapide facultativeCommunications en série Communications USBExploitation de base Pour tous les modèles-bouton MUTE/TEST MUET/TEST Exploitation de base suiteVoyants lumineux Témoin lumineux Power alimentationExploitation de base suite Autres fonctions Entretien Entreposage

SMX & OMNIX specifications

Tripp Lite, a well-known name in the power management industry, offers innovative solutions designed to protect critical electronic equipment from various power disturbances. Among its standout products are the SMX (SmartPro) and OMNIX series of uninterruptible power supplies (UPS). Both series are engineered to cater to diverse needs in the realms of home, office, and data center environments, ensuring maximum performance and reliability.

The SMX series is characterized by its compact design and scalability. It is designed to provide extended battery runtime, making it an ideal choice for critical applications that require consistent power uptime. The SMX units incorporate advanced features such as an LCD panel for real-time monitoring of battery status, load level, and power conditions. Additionally, they are equipped with automatic voltage regulation (AVR) technology that stabilizes voltage fluctuations, protecting connected devices from damage.

One of the key advantages of the SMX series is its flexible configuration options. With multiple outlet types, users can connect different equipment types without worrying about compatibility issues. Moreover, SMX UPS units come with USB and serial ports for easy communication with various systems, allowing for seamless integration into existing setups.

The OMNIX series, on the other hand, focuses on delivering superior performance tailored for larger applications. This line of UPS solutions is designed for mission-critical environments requiring robust power protection. OMNIX units feature advanced battery management technology that optimizes battery life and performance. They also come with a user-friendly interface that provides insights into the UPS status and environment, enabling users to make informed decisions regarding their power management.

Both the SMX and OMNIX series leverage Tripp Lite's signature line-interactive technology, providing automatic voltage regulation to mitigate surges and sags effectively. This technology ensures that connected devices receive clean and consistent power. Additionally, they are built with high-efficiency designs that minimize energy consumption and operational costs, making them an eco-friendly choice.

In terms of reliability, both series are backed by Tripp Lite’s commitment to quality and support. With extensive testing and customer service resources, users can trust that their investments in Tripp Lite products will yield long-lasting performance. Overall, whether users opt for the SMX or OMNIX series, they are assured of gaining state-of-the-art power management solutions that enhance the longevity of their electronic devices while ensuring uninterrupted operation.