All connected equipment should be turned off, then disconnected from the UPS to avoid battery drain. Unplug your UPS from its AC receptacle, then press and hold its ON/OFF button to deactivate it. Your UPS is now ready for storage. If you plan on storing your UPS for an extended period of time, fully recharge the UPS batteries once every three months by plugging the UPS into a live AC outlet and letting the UPS charge for 4 to 6 hours. If you leave your UPS batteries discharged for an extended period of time, they will suffer a permanent loss of capacity.

Service

If returning your UPS for service, contact your local Tripp Lite dealer or distributor. They will refer you to a service center. Please carefully pack the UPS using the ORIGINAL PACKING MATERIAL that came with the unit. Enclose a letter describing the symptoms of the problem. If the UPS is within the warranty period, enclose a copy of your sales receipt.

Specifications

Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice.

Model:

SMART700

SMART750XL

SMART1050

Series:

AGSM1050PJR3

AGSM1500XPSR3

AGSM1050PJR3

Input Voltage/Frequency:

120V/60 Hz

120V/60 Hz

120V/60 Hz

Output Capacity (VA/Watts):

700/600

750/600

1050/800

Battery Runtime

 

 

 

(Half Load/Full Load) Minutes:

20/6

42/18*

23/8

Battery Recharge Time:

2-4 hrs.

2-4 hrs.*

2-4 hrs.

Approvals:

UL, cUL, NOM, FCC B

UL, cUL, NOM, FCC A

UL, cUL, NOM, FCC B

Model:

SMART1050XL

SMART1500

SMART1500XL

Series:

AGSM1500XPSR3

AGSM1500XPSR3

AGSM1500XPSR3

Input Voltage/Frequency:

120V/60 Hz

120V/60 Hz

120V/60 Hz

Output Capacity (VA/Watts):

1050/800

1500/980

1500/980

Battery Runtime

 

 

 

(Half Load/Full Load) Minutes:

26/6*

20/7

20/7*

Battery Recharge Time:

2-4 hrs.*

2-4 hrs.

2-4 hrs.*

Approvals:

UL, cUL, NOM, FCC A

UL, cUL, NOM, FCC A

UL, cUL, NOM, FCC A

*External battery packs can be connected to these models. External battery packs will increase both the battery runtime and the battery recharge time.

ALL UNITS:

Output Waveform Line Mode (filtered sinewave); Output Waveform Battery Mode (PWM sine wave); AC Surge Suppression (exceeds IEEE 587 Cat. A & B standards); AC Noise Attenuation (>40 dB at 1MHz); AC Protection Modes (H to N, H to G, N to G); Tripp Lite External Battery Model (BP36V27).

FCC CLASS A RADIO/TV INTERFERENCE NOTICE:

Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when operated in a com- mercial environment. This equipment generates, uses and can radiate radio frequency energy, and if not installed and used in accordance with the instruction manual, may cause interference to radio communications. Operation of this equipment is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. The user must use shielded cables and connectors with this product. Any changes or modifications to this product not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.

FCC CLASS B RADIO/TV INTERFERENCE NOTICE:

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy, and if not installed and used in accordance with the instruction manual, may cause interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference using one or more of the following measures: reorient or relocate the receiving antenna; increase the separation between the equipment and the receiver; connect the equipment into an outlet on a circuit different from that which the receiver is connected; consult the dealer or an expe- rienced radio/television technician for help. The user must use shielded cables and connectors with this product. Any changes or modifications to this product not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

8

Image 8
Contents SmartPro Important Safety Instructions Battery WarningsUPS Location Warnings UPS Connection WarningsSelect UPS Operating Mode Connect your UPS to An electrical outletQuick Installation optional Charge only Mode Disables battery backup. UPS ButtonsIndicator Lights Other UPS FeaturesNorm Delay Service StorageManual de operación Importantes instrucciones de seguridad Advertencias sobre la ubicación del UPSAdvertencias sobre la conexión del UPS Advertencias sobre la conexión de equiposConecte el sistema UPS a una Toma de corriente Selección del modo de Operación del UPSInstalación rápida optativo Botones Modo de Charge only sólo carga Deshabilita elOperación básica continuación Luces indicadorasOtras características de este sistema UPS Norm Delay Almacenamiento ServicioFicha técnica continuación Guide de lutilisateur Mises en garde relatives à lemplacement du système UPS Importantes consignes de sécuritéMises en garde relatives au raccord du système UPS Mises en garde relatives au raccord de léquipementChoix du mode dexploitation du Système UPS Branchez votre système UPS Dans une prise de secteurBranchement dune batterie Externe modèles choisis Installation rapide facultativeCommunications USB Communications en série Commutateurs Exploitation de base suite Voyants lumineuxPorte de remplacement de la batterie Autres fonctionsNorm Delay Entreposage EntretienSpécifications suite