3 CONTROLS

1)Illuminated ON/OFF Switch:

Move the switch to ON (“I”) to supply power to your connected equipment. This switch will remain illuminated while the PowerVerter is in operation. Move the switch to OFF (“O”) to stop power to your connected equipment. An illuminated indicator above the on/off switch is GREEN when voltage is nominal (above 11.8VDC) and turns RED when the VDC falls to 11.8VDC and below, indicating low battery voltage. An audible alarm will sound if voltage falls to 10.8VDC and below. Automatic shutdown occurs when voltage drops to 10VDC.

2)AC Outlet(s):

Connect equipment to the PowerVerter's receptacles that are designed to run on 120V AC electric power (power tools, appliances, televisions, etc.). Be sure equipment that is plugged into the PowerVerter has a wattage draw equal to or less than the maximum continuous output of your PowerVerter model (see Specifications, page 8).

3)DC Fuses:

The PV 1000 features four DC fuses; the PV 1800 features six. If too much current is drawn from the AC outlets, or in the event of a major electronic failure, the fuses will blow to protect the PowerVerter's circuitry and your battery. If the fuses blow, remove them and replace with 32V automotive fuses of equal amperage (see Specifications, page 8). Note: installing nonrated fuses could

cause equipment damage or failure and could void your warranty.

4)DC Input Terminals:

These two color-coded terminals secure wires leading from the DC battery source. See "Electrical Connection" (page 5) for connection procedure and safety warnings.

5)Cooling Fan(s):

One or two cooling fan(s) regulate your PowerVerter's internal temperature and prolong its life.

PV 1000HF (Front)

1

2

PV 1000HF (Rear)

3

4

5

4

 

 

 

 

PV 1800HF (Front)

PV 1800HF (Rear)

 

 

 

 

Image 4
Contents PowerVerter Ultra Compact Table of Contents IntroductionSafety Low Battery ProtectionControls Operation Electrical ConnectionWire Gauge Chart Troubleshooting MaintenanceSpecifications Model PV 1000HF PV 1800HFWarranty Year Limited WarrantyPowerVerter Ultra Compact Aplicaciones IntroduccionCaracterísticas Avanzadas ¡Advertencia Seguridad¡Precaución Controles Operacion Conexión EléctricaConexión de Equipos Tabla de Calibres para CablesEncendido del Inversor Guia DE Resolucion DE Problemas Guía de Resolución de ProblemasMantenimiento ServicioEspecificaciones Modelo PV 1000HF PV 1800HFGarantía Garantía Limitada DE 1 AÑOPowerVerter Ultra Compacts Applications IntroductionDispositifs Avancés Avertissement Protection de la Batterie FaibleCommutateur Lumineux ON/OFF Prises CAFusibles C.C Terminaux dEntrée C.COperation Connexion ElectriqueConnexion du Matériel Diagramme de Mesure de CâbleMise en route de lInverseur Service MaintenanceGuide de Dépannage Caractéristiques Garantie Garantie Limitée DUN 1 AN93-1900