5.Installation

5.1General Safety Instructions

Read all of these instructions. Save them for future reference.

Follow all warnings and instructions marked on the device.

Do not place the device on any unstable surface (cart, stand, table, etc.). If the device falls, serious damage will result.

Do not use the device near water.

Do not place the device near, or over, radiators or heat registers.

The device cabinet is provided with slots and openings to allow for adequate ventilation. To ensure reliable operation, and to protect against overheating, these openings must never be blocked or covered.

The device should never be placed on a soft surface (bed, sofa, rug, etc.) as this will block its ventilation openings. Likewise, the device should not be placed in a built in enclosure unless adequate ventilation has been provided.

Never spill liquid of any kind on the device.

Unplug the device from the wall outlet before cleaning. Do not use liquid or aerosol cleaners. Use a damp cloth for cleaning.

The device should be operated from the type of power source indicated on the marking label. If you are not sure of the type of power available, consult your dealer or local power company.

This device is designed for IT power distribution systems with up to 230V phase to phase voltage.

The device is equipped with a 3-wire grounding type plug. This is a safety feature. If you are unable to insert the plug into the outlet, contact your electrician to replace your obsolete outlet. Do not attempt to defeat the purpose of the grounding-type plug. Always follow your local/national wiring codes.

Do not allow anything to rest on the power cord or cables. Route the power cord and cables so that they cannot be stepped on or tripped over.

If an extension cord is used with this device make sure that the total of the ampere ratings of all products used on this cord does not exceed the extension cord ampere rating. Make sure that the total of all products plugged into the wall outlet does not exceed 15 amperes.

Consideration should be given to the connection of equipment to the supply circuit, and what effect overloading the supply circuit might have on overcurrent protection and supply wiring.

To help protect your system from sudden, transient increases and decreases in electrical power, use a Tripp Lite surge suppressor, line conditioner, or uninterruptible power supply (UPS).

To help protect your system from sudden, transient increases and decreases in electrical power, use a Tripp Lite surge suppressor, line conditioner, or uninterruptible power supply (UPS).

Position system cables and power cables carefully; be sure that nothing rests on any cables.

When connecting or disconnecting power to hot pluggable power supplies, observe the following guidelines:

Install the power supply before connecting the power cable to the power supply.

Unplug the power cable before removing the power supply.

If the system has multiple sources of power, disconnect power from the system by unplugging all power cables from the power supplies.

Never push objects of any kind into or through cabinet slots. They may touch dangerous voltage points or short out parts resulting in a risk of fire or electrical shock.

Do not attempt to service the device yourself. Refer all servicing to qualified service personnel.

If the following conditions occur, unplug the device from the wall outlet and bring it to qualified service personnel for repair.

The power cord or plug has become damaged or frayed.

Liquid has been spilled into the device.

The device has been exposed to rain or water.

The device has been dropped, or the cabinet has been damaged.

The device exhibits a distinct change in performance, indicating a need for service.

The device does not operate normally when the operating instructions are followed.

Only adjust those controls that are covered in the operating instructions. Improper adjustment of other controls may result in damage that will require extensive work by a qualified technician to repair

Rack Mounting

The ambient operating temperature in the rack may be an issue and is dependent upon the rack load and ventilation. When installing in a closed or multi-unit rack assembly, make sure that the temperature will not exceed the maximum rated ambient temperature (0° to 40° C).

Before working on the rack, make sure that the stabilizers are secured to the rack, extended to the floor, and that the full weight of the rack rests on the floor. Install front and side stabilizers on a single rack or front stabilizers for joined multiple racks before working on the rack.

Always load the rack from the bottom up, and load the heaviest item in the rack first.

Always load the rack so that a hazardous condition is not created due to uneven loading.

Make sure that the rack is level and stable before extending a device from the rack.

Use caution when pressing the device rail release latches and sliding a device into or out of a rack; the slide rails can pinch your fingers.

After a device is inserted into the rack, carefully extend the rail into a locking position, and then slide the device into the rack.

Do not overload the AC supply branch circuit that provides power to the rack. The total rack load should not exceed 80 percent of the branch circuit rating.

Ensure that proper airflow is provided to devices in the rack.

Do not step on or stand on any device when servicing other devices in a rack.

8

Image 8
Contents Console KVM Switch With IP Access Table of Contents Warranty Warranty Registration Java ClientLog File Log ServerPackage Contents FCC InformationUser Notice IntroductionFeatures Supports Radius server authenticationSystem Requirements PS/2 mouse and keyboard ports 6-pin Mini-DIN USB portComponents Keyboard Module See Keyboard Module, sectionLCD module so you can slide it away Standard Rack Mounting, for detailsLCD Module Installation General Safety InstructionsNever spill liquid of any kind on the device Rack MountingSingle-Stage Installation Two-Stage InstallationPower on the second stage KVM switches Standard Rack MountingBasic Operation Opening the ConsoleLCD OSD Configuration Adjustment SettingsUsing the front handle, push the module all the way Closing the ConsoleAdministration Main Choice MeaningPort Operation Configuration Setting FunctionAs Quick View Ports Quick View + Powered on Scroll Lock Scroll Lock or Ctrl Ctrl. SinceAdministration GeneralDescription Heading DescriptionAccess Port Log ServerField Explanation HttpCheck Enable Radius Radius Server Access Rights Network Transfer RateIP Address DNS ServerDefault Webpage Name IP and MAC Filtering192.168.0.126/abcdefg USM0 AllAdministation Login FailuresWorking Mode IP Access cannot be pingedKVM switch Upgrading the FirmwareTo set the time, use the 24 hour Hhmmss format LogTo log in from an Internet browser Browser OperationLogging Webpage Layout Webpage IconsGeneral Dialog Box Webpage ButtonsWindows Client Activating the OSDWindows Client OSD Windows Client Control PanelDialog box. See .1, Activating the OSD, for details Click to exit the remote viewWhen you have finished keying in your sequence, Click Stop Icon Purpose Default HotkeyRGB Gamma AdjustmentOption Usage Button Bar Message Display PanelCompose Panel User List PanelOSD Toolbar Icons Toolbar appears in the upper left corner of the screenMultiuser Operation Keyboard and Mouse Considerations For additional mouse synchronization procedures, see pagesJava Client Java Client OSD Java Client Control PanelWindows Windows XP / Windows ServerWindows ME / Windows Windows NT / WindowsMessage Board Button Bar Clicking the Exit button terminates the Java Client session Log FileLog File on Remote Main Starting Up InstallationLog Server Events Menu has two items Search and Maintenance MaintenanceMenu Bar Menu bar consists of four itemsLog Server Main Screen List PanelKey in the number of seconds, then click OK to finish Log Server Main Screen is divided into two main panelsAP Operation Windows ClientTerm Explanation Click DisconnectTo connect to a port on the KVM switch File MenuTools Menu KeyboardSwitch remote main page displays on your monitor Java ClientEnding the Session Box. Click Disconnect to end the sessionSpecifications OSD Factory Default SettingsFactory default settings are as follows Setting DefaultTroubleshooting Administration Problems Symptom ActionGeneral Operation Problems Symptom Action Java Client Problems Symptom ActionSun Systems Problems Symptom Action Panel Array Mode Problems ActionWindows Client Problems Symptom Action Warranty Warranty RegistrationScreen Resolutions Higher than 1280 x About HD15 Connectors
Related manuals
Manual 3 pages 7.21 Kb

B020-016-17-IP specifications

The Tripp Lite B020-016-17-IP is a robust and versatile 16-Port KVM switch designed for managing multiple servers and workstations in a secure and efficient manner. This device is particularly suitable for data centers and network operations centers where space and efficiency are paramount.

One of the standout features of the B020-016-17-IP is its support for an IP-based remote access functionality, allowing users to control their KVM switch from anywhere over the internet. This is particularly useful for IT administrators who need to manage servers without being physically present, enhancing flexibility and operational efficiency. With this feature, users can easily switch between different servers using a web-based interface.

The B020-016-17-IP supports a wide variety of multimedia formats and audio connections, ensuring that users have a comprehensive experience regardless of their specific setup requirements. This switch is equipped with a standard VGA input, allowing for high-resolution display support, while also protecting against signal degradation. The switch also features USB connectivity for seamless integration with various peripherals.

Another key characteristic of the B020-016-17-IP is its reliable performance, featuring a metal housing that ensures durability and optimal heat dissipation. Users can expect minimal downtime and extended device longevity. The unit is equipped with hot-swappable capabilities, making it easy to replace devices or add new ones without interrupting operations.

Security features are also paramount in this design. The B020-016-17-IP provides a comprehensive range of security protocols, including support for password protection and user authentication, making it suitable for environments where data integrity and confidentiality are crucial.

In terms of installation, the B020-016-17-IP is user-friendly, allowing for a straightforward setup process. It includes various connection options, ensuring compatibility with a wide range of systems and infrastructures.

Overall, the Tripp Lite B020-016-17-IP 16-Port KVM switch combines advanced technology, security, and convenience to offer a powerful solution for remote server management. Whether for small businesses or large enterprises, this KVM switch is an excellent choice for enhancing productivity and streamlining IT operations.