Moxa Technologies EDS-405A, EDS-408A user manual System File Update-By Remote Tftp

Page 27

 

EDS-408A/405A Series User’s Manual

 

 

Featured Functions

 

 

 

 

 

 

 

NOTE

The DIP 1 setting will only be active if DIP 3 is in the ON position. If you set DIP 3 to OFF, then

 

 

the default Ring Coupling port will NOT be enabled, even if DIP 1 is ON.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Protocol

Default Turbo Ring Ports

Default Ring Coupling Port(s)

 

 

 

Turbo Ring

EDS-405A: ports 4 and 5

EDS-405A: ports 2 and 3

 

 

 

EDS-408A: ports 7 and 8

EDS-408A: ports 5 and 6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Turbo Ring V2

EDS-405A:

ports 4 and 5

EDS-405A:

port 2

 

 

 

EDS-408A:

ports 7 and 8

EDS-408A:

port 5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE

The Turbo Ring Ports and Coupling Ports will be added automatically to all VLANs if you set

 

 

DIP Switch 4 to the “ON” position.

 

 

 

 

 

 

 

 

 

 

NOTE

If you do not enable any of the EDS-408A/405A switches to be the Ring Master, the Turbo Ring

 

 

protocol will automatically choose the EDS-408A/405A with the smallest MAC address range to

 

 

be the Ring Master. If you accidentally enable more than one EDS-408A/405A to be the Ring

 

 

Master, these EDS-408A/405A switches will auto-negotiate to determine which one will be the

 

 

Ring Master.

 

 

 

 

 

 

 

 

 

 

 

NOTE

If you use the browser interface to enable the DIP switches (by un-checking the “Disable the

Turbo Ring DIP switch” checkbox), and then flip DIP switch 4 from ON to OFF, the Ring Ports and Coupling Ports that were added to all VLANs will be restored to their previous software settings. (For details, please refer to the “Using Virtual LANs” section of this manual).

System File Update—By Remote TFTP

The EDS supports saving your configuration file to a remote TFTP server or local host to allow other EDS switches to use the same configuration at a later time, or saving the Log file for future reference. Loading pre-saved firmware or a configuration file from the TFTP server or local host is also supported for easy upgrading or configuration of the EDS.

3-12

Image 27
Contents Fourth Edition, June Moxa EtherDevice Switch EDS-408A/405A Series User’s ManualCopyright Notice TrademarksDisclaimer Table of Contents Appendix a MIB Groups Appendix B Specifications Introduction Industrial vs. Commercial Moxa EtherDevice SwitchPackage Checklist Inside the Future of Industrial Ethernet TechnologyAdvanced Industrial Networking Capability Optional AccessoriesFeatures Useful Utility and Remote ConfigurationGetting Started Connection Caution RS-232 Console Configuration 115200, None, 8, 1, VT100EDS-408A/405A Series User’s Manual Getting Started Key Function Configuration Using a Telnet Console Configuration Using a Web Browser EDS-408A/405A Series User’s Manual Getting Started Configuration Disabling Telnet and Browser AccessFeatured Functions System Identification Configuring Basic SettingsPassword PasswordAccount Accessible IP Any host can access the EDS-408A/405AAllowable Hosts Input format Enable PortName Port Type NetworkPort Transmission Speed FDX Flow ControlDefault Gateway Auto IP ConfigurationSwitch IP Address Switch Subnet MaskCurrent Date TimeDaylight Saving Time Current TimeTurbo Ring DIP Switch How to Enable or Disable the Turbo Ring DIP Switches Disable the Turbo Ring DIP SwitchSet DIP switch as Turbo Ring / Set DIP switch as Turbo Ring How to Configure the Turbo Ring DIP Switches Redundancy Protocol drop-down box. See the ConfiguringTurbo Ring and Turbo Ring V2 section in this chapter for System File Update-By Remote Tftp System File Update-By Local Import/Export System File Update-By Backup Media Factory DefaultRestart Snmp Configuring SnmpV1, V2c Write/Read Community Snmp Read/Write SettingsSnmp Versions V1, V2c Read CommunityTrap Server IP/Name Setting Description Factory Default Setting Description Factory DefaultTurbo Ring Concept Using Communication RedundancyInitial setup of a Turbo Ring or Turbo Ring V2 ring Determining the Redundant Path of a Turbo Ring V2 Ring Ring Coupling ConfigurationRing Coupling for a Turbo Ring V2 Ring Dual-Homing Configuration applies only to Turbo Ring Dual-Ring Configuration applies only to Turbo RingMaster/Slave Configuring Turbo Ring and Turbo RingConfiguring Turbo Ring Now ActiveRedundant Ports Enable Ring CouplingRedundancy Protocol Set as MasterRing 1/2-2nd Ring Port Statu Ring 1/2-StatusRing 1/2-Master/Slave Ring 1/2-1st Ring Port StatusCoupling-Coupling Port status Enable RingCoupling-Mode Indicates either None, Dual Homing, or Ring CouplingCoupling Mode Primary/Backup PortSTP/RSTP Concept What is STP? STP Requirements How STP WorksPort Speed Path Cost 802.1D Edition STP ConfigurationSTP Reconfiguration Differences between Rstp and STPSTP Example Using STP on a Network with Multiple VLANsVLAN1 Configuring STP/RSTPBridge priority Forwarding DelayRoot/Not Root Protocol of RedundancyConfiguration Limits of RSTP/STP How Traffic Prioritization Works Using Traffic PrioritizationWhat is Traffic Prioritization? Traffic Prioritization ConceptDifferentiated Services DiffServ Traffic Marking Ieee 802.1p Priority Level Ieee 802.1D Traffic TypeTraffic Prioritization Traffic Queues Inspect TOS Configuring Traffic PrioritizationQoS Classification Queuing MechanismDefault Port Priority Inspect COSCoS Mapping TOS/DiffServ Mapping Using Virtual LANsWhat is a VLAN? Virtual LAN Vlan ConceptUsing Virtual LANs Port-based VLANs and the Moxa EtherDevice SwitchBenefits of VLANs Settings-Turbo Ring DIP Switch Using Rate Limiting Configuring Rate LimitingPolicy Configuring Email Warning Using Auto WarningEvent Types Email Warning Events SettingsConfiguring Email Settings Activate your settings and test email if necessaryEmail Settings MoxaEtherDeviceSwitch0001@SwitchLocationPort Event Configuring Relay Warning Activate your settings Relay Warning Events SettingsUsing Line-Swap-Fast-Recovery Override Relay Warning SettingsRelay Warning List Using Set Device IP Configuring Line-Swap Fast RecoveryEnable Line-Swap-Fast-Recovery Desired IP Address Using DiagnosisConfiguring Set Device IP Mirror PortBi-directional PingInput data stream Output data streamUsing the Monitor Monitor by SwitchMonitor by Port ALL Using the MAC Address TableUsing Syslog Using Event LogSyslog Server EDS Configurator GUI Broadcast Search Starting EDS ConfiguratorSearch by IP address Upgrade FirmwareModify IP Address Export Configuration Import Configuration Unlock Server EDS-408A/405A Series User’s Manual EDS Configurator GUI MIB Groups Optical Fiber PowerTechnology InterfaceMechanical EnvironmentRegulatory Approvals
Related manuals
Manual 86 pages 54.41 Kb

EDS-405A, EDS-408A specifications

Moxa Technologies has established itself as a leader in networking solutions, particularly for industrial applications. Among their cutting-edge products is the 405A Series, specifically the EDS-408A model, which exemplifies Moxa's commitment to performance, reliability, and versatility in industrial Ethernet switches.

The EDS-408A is an 8-port industrial Ethernet switch that offers an impressive array of features and capabilities designed to meet the demands of harsh environments. One of its main highlights is the ability to support both 10/100 Mbps Fast Ethernet and Gigabit Ethernet connections, providing users with the flexibility to integrate a range of devices within their network. Its robust design ensures that it operates seamlessly in extreme conditions, with a wide operating temperature range from -40 to 75 degrees Celsius.

The EDS-408A is built to support an array of networking topologies. It features advanced Ethernet switching technologies that enable fast and efficient data transfer while minimizing latency. The device is equipped with wire-speed forwarding capabilities, which is vital for maintaining high performance in heavy network traffic scenarios.

Another key feature of the EDS-408A is its redundancy support. The switch incorporates various redundancy protocols, including Rapid Spanning Tree Protocol (RSTP) and MRP (Media Redundancy Protocol), which enhance network reliability by allowing quick recovery in the event of a failure. This ensures continuous network uptime, which is critical for industrial applications.

Furthermore, Moxa Technologies has adopted an user-friendly web-based management interface in the EDS-408A, simplifying the configuration and monitoring process. This allows system administrators to easily manage settings, monitor traffic, and troubleshoot issues in real time. Additionally, the switch supports SNMP (Simple Network Management Protocol) for remote monitoring and management, enabling organizations to keep their networks optimized.

Security is another paramount feature of the EDS-408A. It includes built-in security mechanisms such as port security, VLAN, and access control lists (ACLs), which help safeguard sensitive network segments from unauthorized access.

In conclusion, Moxa Technologies' EDS-408A model from the 405A Series is a robust and feature-rich industrial Ethernet switch designed for demanding environments. With its support for various network protocols, redundancy features, user-friendly management, and enhanced security, the EDS-408A stands out as a reliable solution for organizations looking to enhance their industrial networking capabilities.