Moxa Technologies EDS-405A Snmp Read/Write Settings, Snmp Versions, V1, V2c Read Community

Page 31

EDS-408A/405A Series User’s Manual

Featured Functions

SNMP Read/Write Settings

SNMP Versions

Setting

Description

 

Factory Default

V1, V2c, V3

Select SNMP protocol versions V1, V2c,

 

 

V3 to manage the switch

 

 

 

 

 

V1, V2c

Select SNMP protocol versions V1, V2c to

 

V1, V2c

 

manage the switch

 

 

V3 only

Select only SNMP protocol version V3 to

 

 

manage the switch

 

 

 

 

 

V1, V2c Read Community

 

 

 

 

 

 

 

Setting

Description

 

Factory Default

 

Use a community string match for

 

 

V1, V2c Read

authentication. This means that the SNMP

 

public

Community

agent accesses all objects with read-only

 

Maximum 30 characters

permissions using the community string

 

 

 

 

 

public.

 

 

V1, V2c Write/Read Community

 

 

Setting

Description

 

 

Factory Default

V1, V2c

Uses a community string match for

 

 

 

authentication, which means that SNMP

 

private

Read/Write

servers access all objects with read/write

 

 

Maximum 30 characters

Community

permissions using the community string

 

 

 

 

 

private.

 

 

 

For SNMP V3, there are two levels of privilege for different accounts to access the EDS. Admin privilege allows access, and authorization to read and write the MIB file. User privilege only allows reading the MIB file, but does not authorize writing.

3-16

Image 31
Contents Fourth Edition, June Moxa EtherDevice Switch EDS-408A/405A Series User’s ManualTrademarks Copyright NoticeDisclaimer Table of Contents Appendix a MIB Groups Appendix B Specifications Introduction Industrial vs. Commercial Moxa EtherDevice SwitchPackage Checklist Inside the Future of Industrial Ethernet TechnologyAdvanced Industrial Networking Capability Optional AccessoriesFeatures Useful Utility and Remote ConfigurationGetting Started Connection Caution RS-232 Console Configuration 115200, None, 8, 1, VT100EDS-408A/405A Series User’s Manual Getting Started Key Function Configuration Using a Telnet Console Configuration Using a Web Browser EDS-408A/405A Series User’s Manual Getting Started Configuration Disabling Telnet and Browser AccessFeatured Functions System Identification Configuring Basic SettingsPassword PasswordAccount Any host can access the EDS-408A/405A Accessible IPAllowable Hosts Input format Port EnableName Port Type NetworkPort Transmission Speed FDX Flow ControlDefault Gateway Auto IP ConfigurationSwitch IP Address Switch Subnet MaskCurrent Date TimeDaylight Saving Time Current TimeTurbo Ring DIP Switch Disable the Turbo Ring DIP Switch How to Enable or Disable the Turbo Ring DIP SwitchesSet DIP switch as Turbo Ring / Set DIP switch as Turbo Ring Redundancy Protocol drop-down box. See the Configuring How to Configure the Turbo Ring DIP SwitchesTurbo Ring and Turbo Ring V2 section in this chapter for System File Update-By Remote Tftp System File Update-By Local Import/Export Factory Default System File Update-By Backup MediaRestart Snmp Configuring SnmpV1, V2c Write/Read Community Snmp Read/Write SettingsSnmp Versions V1, V2c Read CommunityTrap Server IP/Name Setting Description Factory Default Setting Description Factory DefaultTurbo Ring Concept Using Communication RedundancyInitial setup of a Turbo Ring or Turbo Ring V2 ring Determining the Redundant Path of a Turbo Ring V2 Ring Ring Coupling ConfigurationRing Coupling for a Turbo Ring V2 Ring Dual-Homing Configuration applies only to Turbo Ring Dual-Ring Configuration applies only to Turbo RingMaster/Slave Configuring Turbo Ring and Turbo RingConfiguring Turbo Ring Now ActiveRedundant Ports Enable Ring CouplingRedundancy Protocol Set as MasterRing 1/2-2nd Ring Port Statu Ring 1/2-StatusRing 1/2-Master/Slave Ring 1/2-1st Ring Port StatusCoupling-Coupling Port status Enable RingCoupling-Mode Indicates either None, Dual Homing, or Ring CouplingPrimary/Backup Port Coupling ModeSTP/RSTP Concept What is STP? STP Requirements How STP WorksPort Speed Path Cost 802.1D Edition STP ConfigurationSTP Reconfiguration Differences between Rstp and STPSTP Example Using STP on a Network with Multiple VLANsVLAN1 Configuring STP/RSTPBridge priority Forwarding DelayRoot/Not Root Protocol of RedundancyConfiguration Limits of RSTP/STP How Traffic Prioritization Works Using Traffic PrioritizationWhat is Traffic Prioritization? Traffic Prioritization ConceptIeee 802.1p Priority Level Ieee 802.1D Traffic Type Differentiated Services DiffServ Traffic MarkingTraffic Prioritization Traffic Queues Inspect TOS Configuring Traffic PrioritizationQoS Classification Queuing MechanismInspect COS Default Port PriorityCoS Mapping TOS/DiffServ Mapping Using Virtual LANsWhat is a VLAN? Virtual LAN Vlan ConceptPort-based VLANs and the Moxa EtherDevice Switch Using Virtual LANsBenefits of VLANs Settings-Turbo Ring DIP Switch Configuring Rate Limiting Using Rate LimitingPolicy Configuring Email Warning Using Auto WarningEvent Types Email Warning Events SettingsConfiguring Email Settings Activate your settings and test email if necessaryMoxaEtherDeviceSwitch0001@SwitchLocation Email SettingsPort Event Configuring Relay Warning Activate your settings Relay Warning Events SettingsOverride Relay Warning Settings Using Line-Swap-Fast-RecoveryRelay Warning List Configuring Line-Swap Fast Recovery Using Set Device IPEnable Line-Swap-Fast-Recovery Desired IP Address Using DiagnosisConfiguring Set Device IP Mirror PortBi-directional PingInput data stream Output data streamMonitor by Switch Using the MonitorMonitor by Port ALL Using the MAC Address TableUsing Syslog Using Event LogSyslog Server EDS Configurator GUI Broadcast Search Starting EDS ConfiguratorSearch by IP address Upgrade FirmwareModify IP Address Export Configuration Import Configuration Unlock Server EDS-408A/405A Series User’s Manual EDS Configurator GUI MIB Groups Optical Fiber PowerTechnology InterfaceEnvironment MechanicalRegulatory Approvals
Related manuals
Manual 86 pages 54.41 Kb

EDS-405A, EDS-408A specifications

Moxa Technologies has established itself as a leader in networking solutions, particularly for industrial applications. Among their cutting-edge products is the 405A Series, specifically the EDS-408A model, which exemplifies Moxa's commitment to performance, reliability, and versatility in industrial Ethernet switches.

The EDS-408A is an 8-port industrial Ethernet switch that offers an impressive array of features and capabilities designed to meet the demands of harsh environments. One of its main highlights is the ability to support both 10/100 Mbps Fast Ethernet and Gigabit Ethernet connections, providing users with the flexibility to integrate a range of devices within their network. Its robust design ensures that it operates seamlessly in extreme conditions, with a wide operating temperature range from -40 to 75 degrees Celsius.

The EDS-408A is built to support an array of networking topologies. It features advanced Ethernet switching technologies that enable fast and efficient data transfer while minimizing latency. The device is equipped with wire-speed forwarding capabilities, which is vital for maintaining high performance in heavy network traffic scenarios.

Another key feature of the EDS-408A is its redundancy support. The switch incorporates various redundancy protocols, including Rapid Spanning Tree Protocol (RSTP) and MRP (Media Redundancy Protocol), which enhance network reliability by allowing quick recovery in the event of a failure. This ensures continuous network uptime, which is critical for industrial applications.

Furthermore, Moxa Technologies has adopted an user-friendly web-based management interface in the EDS-408A, simplifying the configuration and monitoring process. This allows system administrators to easily manage settings, monitor traffic, and troubleshoot issues in real time. Additionally, the switch supports SNMP (Simple Network Management Protocol) for remote monitoring and management, enabling organizations to keep their networks optimized.

Security is another paramount feature of the EDS-408A. It includes built-in security mechanisms such as port security, VLAN, and access control lists (ACLs), which help safeguard sensitive network segments from unauthorized access.

In conclusion, Moxa Technologies' EDS-408A model from the 405A Series is a robust and feature-rich industrial Ethernet switch designed for demanding environments. With its support for various network protocols, redundancy features, user-friendly management, and enhanced security, the EDS-408A stands out as a reliable solution for organizations looking to enhance their industrial networking capabilities.