Moxa Technologies EDS-408A, EDS-405A user manual Inspect COS, Default Port Priority, CoS Mapping

Page 54

EDS-408A/405A Series User’s Manual

Featured Functions

Inspect COS

 

 

 

 

Setting

Description

 

Factory Default

 

Enable/Disable

Select this setting to enable the EDS-408A/405A to

 

Enable

 

inspect the 802.1p COS tag in the MAC frame to

 

 

 

determine the priority of each frame.

 

 

 

Default Port Priority

 

 

 

 

 

 

Setting

 

Description

 

Factory Default

 

 

 

Low/Normal/

 

Set the Port Default Priority of the ingress frames to

 

 

 

 

 

 

different priority queues. If the received packets are

 

Normal

 

 

 

Medium/High

 

not equipped with any tag information (CoS, TOS) the

 

 

 

 

 

 

default port priority will take effect.

 

 

 

 

 

 

NOTE

The priority of an ingress frame is determined in order by:

 

 

 

1.

Inspect TOS

 

 

 

 

2.

Inspect CoS

 

 

 

 

3.

Default Port Priority

 

 

 

 

 

 

NOTE

The designer can enable these classifications individually or in combination. For instance, if a

 

‘hot’ higher priority port is required for a network design, Inspect TOS and Inspect CoS can be

disabled. This setting leaves only port default priority active, which results in all ingress frames being assigned the same priority on that port.

CoS Mapping

 

Setting

Description

Factory Default

 

 

 

0: Low

 

 

 

1: Low

 

Low/Normal/

Set the mapping table of different CoS values to 4

2: Normal

 

3: Normal

 

Medium/High

different egress queues.

4: Medium

 

 

 

5: Medium

 

 

 

6: High

 

 

 

7: High

3-39

Image 54
Contents Moxa EtherDevice Switch EDS-408A/405A Series User’s Manual Fourth Edition, JuneCopyright Notice TrademarksDisclaimer Table of Contents Appendix a MIB Groups Appendix B Specifications Introduction Inside the Future of Industrial Ethernet Technology Moxa EtherDevice SwitchPackage Checklist Industrial vs. CommercialUseful Utility and Remote Configuration Optional AccessoriesFeatures Advanced Industrial Networking CapabilityGetting Started RS-232 Console Configuration 115200, None, 8, 1, VT100 Connection CautionEDS-408A/405A Series User’s Manual Getting Started Key Function Configuration Using a Telnet Console Configuration Using a Web Browser EDS-408A/405A Series User’s Manual Getting Started Disabling Telnet and Browser Access ConfigurationFeatured Functions Configuring Basic Settings System IdentificationPassword PasswordAccount Accessible IP Any host can access the EDS-408A/405AAllowable Hosts Input format Enable PortName FDX Flow Control NetworkPort Transmission Speed Port TypeSwitch Subnet Mask Auto IP ConfigurationSwitch IP Address Default GatewayCurrent Time TimeDaylight Saving Time Current DateTurbo Ring DIP Switch How to Enable or Disable the Turbo Ring DIP Switches Disable the Turbo Ring DIP SwitchSet DIP switch as Turbo Ring / Set DIP switch as Turbo Ring How to Configure the Turbo Ring DIP Switches Redundancy Protocol drop-down box. See the ConfiguringTurbo Ring and Turbo Ring V2 section in this chapter for System File Update-By Remote Tftp System File Update-By Local Import/Export System File Update-By Backup Media Factory DefaultRestart Configuring Snmp SnmpV1, V2c Read Community Snmp Read/Write SettingsSnmp Versions V1, V2c Write/Read CommunitySetting Description Factory Default Trap Server IP/Name Setting Description Factory DefaultUsing Communication Redundancy Turbo Ring ConceptInitial setup of a Turbo Ring or Turbo Ring V2 ring Ring Coupling Configuration Determining the Redundant Path of a Turbo Ring V2 RingRing Coupling for a Turbo Ring V2 Ring Dual-Ring Configuration applies only to Turbo Ring Dual-Homing Configuration applies only to Turbo RingNow Active Configuring Turbo Ring and Turbo RingConfiguring Turbo Ring Master/SlaveSet as Master Enable Ring CouplingRedundancy Protocol Redundant PortsRing 1/2-1st Ring Port Status Ring 1/2-StatusRing 1/2-Master/Slave Ring 1/2-2nd Ring Port StatuIndicates either None, Dual Homing, or Ring Coupling Enable RingCoupling-Mode Coupling-Coupling Port statusCoupling Mode Primary/Backup PortSTP/RSTP Concept What is STP? How STP Works STP RequirementsDifferences between Rstp and STP STP ConfigurationSTP Reconfiguration Port Speed Path Cost 802.1D EditionUsing STP on a Network with Multiple VLANs STP ExampleConfiguring STP/RSTP VLAN1Protocol of Redundancy Forwarding DelayRoot/Not Root Bridge priorityConfiguration Limits of RSTP/STP Traffic Prioritization Concept Using Traffic PrioritizationWhat is Traffic Prioritization? How Traffic Prioritization WorksDifferentiated Services DiffServ Traffic Marking Ieee 802.1p Priority Level Ieee 802.1D Traffic TypeTraffic Prioritization Traffic Queues Queuing Mechanism Configuring Traffic PrioritizationQoS Classification Inspect TOSDefault Port Priority Inspect COSCoS Mapping Virtual LAN Vlan Concept Using Virtual LANsWhat is a VLAN? TOS/DiffServ MappingUsing Virtual LANs Port-based VLANs and the Moxa EtherDevice SwitchBenefits of VLANs Settings-Turbo Ring DIP Switch Using Rate Limiting Configuring Rate LimitingPolicy Using Auto Warning Configuring Email WarningActivate your settings and test email if necessary Email Warning Events SettingsConfiguring Email Settings Event TypesEmail Settings MoxaEtherDeviceSwitch0001@SwitchLocationPort Event Configuring Relay Warning Relay Warning Events Settings Activate your settingsUsing Line-Swap-Fast-Recovery Override Relay Warning SettingsRelay Warning List Using Set Device IP Configuring Line-Swap Fast RecoveryEnable Line-Swap-Fast-Recovery Mirror Port Using DiagnosisConfiguring Set Device IP Desired IP AddressOutput data stream PingInput data stream Bi-directionalUsing the Monitor Monitor by SwitchMonitor by Port Using the MAC Address Table ALLUsing Event Log Using SyslogSyslog Server EDS Configurator GUI Starting EDS Configurator Broadcast SearchUpgrade Firmware Search by IP addressModify IP Address Export Configuration Import Configuration Unlock Server EDS-408A/405A Series User’s Manual EDS Configurator GUI MIB Groups Interface PowerTechnology Optical FiberMechanical EnvironmentRegulatory Approvals
Related manuals
Manual 86 pages 54.41 Kb

EDS-405A, EDS-408A specifications

Moxa Technologies has established itself as a leader in networking solutions, particularly for industrial applications. Among their cutting-edge products is the 405A Series, specifically the EDS-408A model, which exemplifies Moxa's commitment to performance, reliability, and versatility in industrial Ethernet switches.

The EDS-408A is an 8-port industrial Ethernet switch that offers an impressive array of features and capabilities designed to meet the demands of harsh environments. One of its main highlights is the ability to support both 10/100 Mbps Fast Ethernet and Gigabit Ethernet connections, providing users with the flexibility to integrate a range of devices within their network. Its robust design ensures that it operates seamlessly in extreme conditions, with a wide operating temperature range from -40 to 75 degrees Celsius.

The EDS-408A is built to support an array of networking topologies. It features advanced Ethernet switching technologies that enable fast and efficient data transfer while minimizing latency. The device is equipped with wire-speed forwarding capabilities, which is vital for maintaining high performance in heavy network traffic scenarios.

Another key feature of the EDS-408A is its redundancy support. The switch incorporates various redundancy protocols, including Rapid Spanning Tree Protocol (RSTP) and MRP (Media Redundancy Protocol), which enhance network reliability by allowing quick recovery in the event of a failure. This ensures continuous network uptime, which is critical for industrial applications.

Furthermore, Moxa Technologies has adopted an user-friendly web-based management interface in the EDS-408A, simplifying the configuration and monitoring process. This allows system administrators to easily manage settings, monitor traffic, and troubleshoot issues in real time. Additionally, the switch supports SNMP (Simple Network Management Protocol) for remote monitoring and management, enabling organizations to keep their networks optimized.

Security is another paramount feature of the EDS-408A. It includes built-in security mechanisms such as port security, VLAN, and access control lists (ACLs), which help safeguard sensitive network segments from unauthorized access.

In conclusion, Moxa Technologies' EDS-408A model from the 405A Series is a robust and feature-rich industrial Ethernet switch designed for demanding environments. With its support for various network protocols, redundancy features, user-friendly management, and enhanced security, the EDS-408A stands out as a reliable solution for organizations looking to enhance their industrial networking capabilities.