Moxa Technologies EDS-405A, EDS-408A user manual Ring Coupling Configuration

Page 35

EDS-408A/405A Series User’s Manual

Featured Functions

“Turbo Ring” rings with an odd number of EDS units

Master

If there are 2N+1 EDS units (an odd number) in the “Turbo Ring” ring, with EDS units and segments labeled counterclockwise, then segment N+1 will serve as the backup path.

For the example shown here, N=1, so that N+1=2.

Segment N+1

Determining the Redundant Path of a “Turbo Ring V2” Ring

Master

For a “Turbo Ring V2” ring, the backup segment is the segment connected to the 2nd redundant port on the master.

See Configuring “Turbo Ring V2” in the

Configuring “Turbo Ring” and “Turbo Ring V2” section below.

Ring Coupling Configuration

For some systems, it may not be convenient to connect all devices in the system to create one BIG redundant ring, since some devices could be located in a remote area. For these systems, “Ring Coupling” can be used to separate the devices into different smaller redundant rings, but in such a way that they can still communicate with each other.

ATTENTION

In a VLAN environment, the user must set “Redundant Port,” “Coupling Port,” and “Coupling Control Port” to join all VLANs, since these ports act as the “backbone” to transmit all packets of different VLANs to different EDS units.

3-20

Image 35
Contents Fourth Edition, June Moxa EtherDevice Switch EDS-408A/405A Series User’s ManualDisclaimer Copyright NoticeTrademarks Table of Contents Appendix a MIB Groups Appendix B Specifications Introduction Industrial vs. Commercial Moxa EtherDevice SwitchPackage Checklist Inside the Future of Industrial Ethernet TechnologyAdvanced Industrial Networking Capability Optional AccessoriesFeatures Useful Utility and Remote ConfigurationGetting Started Connection Caution RS-232 Console Configuration 115200, None, 8, 1, VT100EDS-408A/405A Series User’s Manual Getting Started Key Function Configuration Using a Telnet Console Configuration Using a Web Browser EDS-408A/405A Series User’s Manual Getting Started Configuration Disabling Telnet and Browser AccessFeatured Functions System Identification Configuring Basic SettingsAccount PasswordPassword Allowable Hosts Input format Accessible IPAny host can access the EDS-408A/405A Name EnablePort Port Type NetworkPort Transmission Speed FDX Flow ControlDefault Gateway Auto IP ConfigurationSwitch IP Address Switch Subnet MaskCurrent Date TimeDaylight Saving Time Current TimeTurbo Ring DIP Switch Set DIP switch as Turbo Ring / Set DIP switch as Turbo Ring How to Enable or Disable the Turbo Ring DIP SwitchesDisable the Turbo Ring DIP Switch Turbo Ring and Turbo Ring V2 section in this chapter for How to Configure the Turbo Ring DIP SwitchesRedundancy Protocol drop-down box. See the Configuring System File Update-By Remote Tftp System File Update-By Local Import/Export Restart System File Update-By Backup MediaFactory Default Snmp Configuring SnmpV1, V2c Write/Read Community Snmp Read/Write SettingsSnmp Versions V1, V2c Read CommunityTrap Server IP/Name Setting Description Factory Default Setting Description Factory DefaultTurbo Ring Concept Using Communication RedundancyInitial setup of a Turbo Ring or Turbo Ring V2 ring Determining the Redundant Path of a Turbo Ring V2 Ring Ring Coupling ConfigurationRing Coupling for a Turbo Ring V2 Ring Dual-Homing Configuration applies only to Turbo Ring Dual-Ring Configuration applies only to Turbo RingMaster/Slave Configuring Turbo Ring and Turbo RingConfiguring Turbo Ring Now ActiveRedundant Ports Enable Ring CouplingRedundancy Protocol Set as MasterRing 1/2-2nd Ring Port Statu Ring 1/2-StatusRing 1/2-Master/Slave Ring 1/2-1st Ring Port StatusCoupling-Coupling Port status Enable RingCoupling-Mode Indicates either None, Dual Homing, or Ring CouplingSTP/RSTP Concept Coupling ModePrimary/Backup Port What is STP? STP Requirements How STP WorksPort Speed Path Cost 802.1D Edition STP ConfigurationSTP Reconfiguration Differences between Rstp and STPSTP Example Using STP on a Network with Multiple VLANsVLAN1 Configuring STP/RSTPBridge priority Forwarding DelayRoot/Not Root Protocol of RedundancyConfiguration Limits of RSTP/STP How Traffic Prioritization Works Using Traffic PrioritizationWhat is Traffic Prioritization? Traffic Prioritization ConceptTraffic Prioritization Differentiated Services DiffServ Traffic MarkingIeee 802.1p Priority Level Ieee 802.1D Traffic Type Traffic Queues Inspect TOS Configuring Traffic PrioritizationQoS Classification Queuing MechanismCoS Mapping Default Port PriorityInspect COS TOS/DiffServ Mapping Using Virtual LANsWhat is a VLAN? Virtual LAN Vlan ConceptBenefits of VLANs Using Virtual LANsPort-based VLANs and the Moxa EtherDevice Switch Settings-Turbo Ring DIP Switch Policy Using Rate LimitingConfiguring Rate Limiting Configuring Email Warning Using Auto WarningEvent Types Email Warning Events SettingsConfiguring Email Settings Activate your settings and test email if necessaryPort Event Email SettingsMoxaEtherDeviceSwitch0001@SwitchLocation Configuring Relay Warning Activate your settings Relay Warning Events SettingsRelay Warning List Using Line-Swap-Fast-RecoveryOverride Relay Warning Settings Enable Line-Swap-Fast-Recovery Using Set Device IPConfiguring Line-Swap Fast Recovery Desired IP Address Using DiagnosisConfiguring Set Device IP Mirror PortBi-directional PingInput data stream Output data streamMonitor by Port Using the MonitorMonitor by Switch ALL Using the MAC Address TableUsing Syslog Using Event LogSyslog Server EDS Configurator GUI Broadcast Search Starting EDS ConfiguratorSearch by IP address Upgrade FirmwareModify IP Address Export Configuration Import Configuration Unlock Server EDS-408A/405A Series User’s Manual EDS Configurator GUI MIB Groups Optical Fiber PowerTechnology InterfaceRegulatory Approvals MechanicalEnvironment
Related manuals
Manual 86 pages 54.41 Kb

EDS-405A, EDS-408A specifications

Moxa Technologies has established itself as a leader in networking solutions, particularly for industrial applications. Among their cutting-edge products is the 405A Series, specifically the EDS-408A model, which exemplifies Moxa's commitment to performance, reliability, and versatility in industrial Ethernet switches.

The EDS-408A is an 8-port industrial Ethernet switch that offers an impressive array of features and capabilities designed to meet the demands of harsh environments. One of its main highlights is the ability to support both 10/100 Mbps Fast Ethernet and Gigabit Ethernet connections, providing users with the flexibility to integrate a range of devices within their network. Its robust design ensures that it operates seamlessly in extreme conditions, with a wide operating temperature range from -40 to 75 degrees Celsius.

The EDS-408A is built to support an array of networking topologies. It features advanced Ethernet switching technologies that enable fast and efficient data transfer while minimizing latency. The device is equipped with wire-speed forwarding capabilities, which is vital for maintaining high performance in heavy network traffic scenarios.

Another key feature of the EDS-408A is its redundancy support. The switch incorporates various redundancy protocols, including Rapid Spanning Tree Protocol (RSTP) and MRP (Media Redundancy Protocol), which enhance network reliability by allowing quick recovery in the event of a failure. This ensures continuous network uptime, which is critical for industrial applications.

Furthermore, Moxa Technologies has adopted an user-friendly web-based management interface in the EDS-408A, simplifying the configuration and monitoring process. This allows system administrators to easily manage settings, monitor traffic, and troubleshoot issues in real time. Additionally, the switch supports SNMP (Simple Network Management Protocol) for remote monitoring and management, enabling organizations to keep their networks optimized.

Security is another paramount feature of the EDS-408A. It includes built-in security mechanisms such as port security, VLAN, and access control lists (ACLs), which help safeguard sensitive network segments from unauthorized access.

In conclusion, Moxa Technologies' EDS-408A model from the 405A Series is a robust and feature-rich industrial Ethernet switch designed for demanding environments. With its support for various network protocols, redundancy features, user-friendly management, and enhanced security, the EDS-408A stands out as a reliable solution for organizations looking to enhance their industrial networking capabilities.