Schneider Electric E4800 manual Configuring the meter, Login screen

Page 13

930-112-01

 

PowerLogicTM E4800 Series

02/2009

 

PowerLogic E4800 configuration tool guide

 

 

 

 

5.

Restore power. When control power is restored, the meter will receive

 

 

an IP address from a local DHCP server. This IP address can be

 

 

viewed from the Diagnostics menu.

 

 

NOTE: To use a static IP address, have your local network

 

 

administrator assign the desired IP address to the MAC address of the

 

 

meter in the DHCP server configuration.

PowerLogic Configuration Tool

The PowerLogic E4800 configuration tool is available on the CD shipped with

 

each unit, and is used to configure all programmable parameters listed in

 

Table 1.

Configuring the meter

Use the following procedure to configure the meter.

 

1.

Establish an Ethernet network connection with the meter using one of

 

 

the methods descirbed in “Communications Connections” on page 5.

 

2.

Ensure the programming switches are in the ON position. The

 

 

programming switches are two-position DIP switches labeled SW1, and

 

 

are located inside the meter cover below the Display button. To enable

 

 

meter configuration, both switches must be physically set to the ON

 

 

position. When both switches are in the OFF position, meter

 

 

configuration is disabled.

 

3.

Start the configuration tool by entering “PowerLogic” as the User

 

 

Name, and “E4800” as the Password (see Figure 1). Click Ok.

Figure 2: Login screen

© 2009 Schneider Electric All Rights Reserved

7

Image 13
Contents PowerLogicTM Series E4800 PowerLogicTM E4800 Series 930-112-01 02/2009 Hazard Categories and Special SymbolsPowerLogicTM E4800 Series PowerLogicTM E4800 Series 930-112-01 02/2009 Table of Contents Schneider Electric All Rights Reserved Configuration and Programming Powerlogic E4800 Configuration Tool GuideParameter Read access Write access Activation time Programming access to meter parametersMeter and probe points ManufacturingDiagnostics Mode Normal ModeDisplay Navigation Direct Connection Ethernet Requirements Communications ConnectionsInjury Network Connection Ethernet Requirements Login screen Configuring the meterConfiguration tool main window Discovered Units dialog box Main configuration window with configured parameters Field Parameter Description Configuration parametersReport Parameters Parameter Description By selecting the check box Daily Minutes PowerLogic E4805 PowerLogic E4833 PowerLogic E4880 List of supported metering configurationsMeter Points Circuits Tab Meter Point ConfigurationBadge Numbering Badge Numbering pane Factor applied to the collected pulse counts Pulse Probes TabE4800 meter is ready to be programmed. Proceed as follows Completing the Meter ConfigurationSending the configured settings to the meter 930-112-01 Schneider Electric USA
Related manuals
Manual 48 pages 53.63 Kb

E4800 specifications

Schneider Electric's E4800 is a robust solution designed for comprehensive energy management, combining advanced features, innovative technologies, and user-friendly characteristics that cater to the needs of various industries. This device primarily focuses on enhancing efficiency in energy consumption and optimizing operational performance.

One of the standout features of the E4800 is its ability to monitor and manage energy consumption in real-time. This capability allows businesses to identify energy usage patterns, track costs, and gain insights into where energy can be saved. The real-time data analysis supports decision-making, enabling organizations to implement energy-saving strategies effectively.

The E4800 is equipped with an intuitive user interface that simplifies navigation and data interpretation. Users can access detailed analytics and reporting tools that provide visibility into energy performance metrics. This user-friendly aspect ensures that both technical and non-technical staff can utilize the system, fostering a culture of energy efficiency across the organization.

Additionally, Schneider Electric has integrated advanced communication technologies into the E4800. It supports various communication protocols such as Modbus, BACnet, and Ethernet, enabling seamless integration with existing systems and infrastructure. This versatility ensures that organizations can leverage their current investments in technology while upgrading to more advanced energy management solutions.

The E4800 is also designed with scalability in mind. Organizations can easily expand their energy management capabilities as their needs grow. Whether managing a single facility or a multi-site operation, the E4800 can adapt to varying requirements without significant overhauls or disruptions.

Another noteworthy characteristic is its compliance with global standards for energy management and sustainability. By utilizing the E4800, companies can demonstrate their commitment to environmental responsibility and adherence to regulations, which is increasingly important in today’s business landscape.

Lastly, Schneider Electric's E4800 comes with robust support services, ensuring that users can access assistance whenever needed. This commitment to customer service solidifies its position as a reliable solution for energy management.

In summary, Schneider Electric's E4800 offers a comprehensive suite of features designed for effective energy management, leveraging real-time analytics, versatile communication technologies, scalability, compliance with global standards, and excellent customer support, making it an ideal choice for businesses aiming to enhance their energy efficiency and sustainability.