Schneider Electric E4800 manual Manufacturing, Meter and probe points

Page 9

930-112-01

 

 

PowerLogicTM E4800 Series

02/2009

 

 

PowerLogic E4800 configuration tool guide

 

 

 

 

 

 

 

 

 

 

 

Parameter

Read access

Write access

Activation time

 

 

 

 

 

 

FTP user name

Configuration tool

Configuration tool

Immediate

 

 

 

 

 

 

FTP password

Configuration tool

Configuration tool

Immediate

 

 

 

 

 

 

Report period start time

Configuration tool

Configuration tool

Immediate

 

 

 

 

 

 

Report period end time

Configuration tool

Configuration tool

Immediate

 

 

 

 

 

 

Report interval

Configuration tool

Configuration tool

Immediate

 

 

 

 

 

 

Data interval in minutes

Configuration tool

Configuration tool

Immediate

 

 

 

 

 

 

PT ratio

Configuration tool

Configuration tool +

Immediate

 

 

 

prog. switch ON

 

 

 

 

 

 

 

Encryption

Configuration tool

Configuration tool

Immediate

 

 

 

 

 

 

MODBUS address

Configuration tool

No Access

Immediate

 

 

 

 

 

 

Default IP address

Configuration tool

Configuration tool

Immediate

 

 

 

 

 

 

Default netmask

Configuration tool

Configuration tool

Immediate

 

 

 

 

 

 

Default gateway

Configuration tool

Configuration tool

Immediate

 

 

 

 

 

 

Reset dial readings

No Access

Configuration tool +

Immediate

 

 

 

prog. switch ON

 

 

 

 

 

 

 

Programming switch state

Configuration tool

No Access

Immediate

 

 

 

 

 

 

MAC address

Configuration tool

No Access

Immediate

 

 

 

 

 

 

Report types

Configuration tool

Configuration tool

Immediate

 

 

 

 

 

 

Manufacturing

 

 

 

 

 

 

 

 

 

Serial number

Configuration tool

No Access

N/A

 

 

 

 

 

 

Part number

Configuration tool

No Access

N/A

 

 

 

 

 

 

Model number

Configuration tool

Configuration tool +

After reset

 

 

 

prog. switch ON

 

 

 

 

 

 

 

Revision

Configuration tool

No Access

 

 

 

 

 

 

 

Firmware revision

Configuration tool

No Access

N/A

 

 

 

 

 

 

Build number

Configuration tool

No Access

 

 

 

 

 

 

 

Meter and probe points

 

 

 

 

 

 

 

 

 

Name

Configuration tool

Configuration tool

After reset

 

 

 

 

 

 

CT 1 current

Configuration tool

Configuration tool +

After reset

 

 

 

prog. switch ON

 

 

 

 

 

 

 

CT 2 current

Configuration tool

Configuration tool +

After reset

 

 

 

prog. switch ON

 

 

 

 

 

 

 

CT 3 current

Configuration tool

Configuration tool +

After reset

 

 

 

prog. switch ON

 

 

 

 

 

 

 

CT 1 phase

Configuration tool

Configuration tool +

After reset

 

 

 

prog. switch ON

 

 

 

 

 

 

 

CT 2 phase

Configuration tool

Configuration tool +

After reset

 

 

 

prog. switch ON

 

 

 

 

 

 

© 2009 Schneider Electric All Rights Reserved

3

Image 9
Contents PowerLogicTM Series E4800 PowerLogicTM E4800 Series 930-112-01 02/2009 Hazard Categories and Special SymbolsPowerLogicTM E4800 Series PowerLogicTM E4800 Series 930-112-01 02/2009 Table of Contents Schneider Electric All Rights Reserved Configuration and Programming Powerlogic E4800 Configuration Tool GuideParameter Read access Write access Activation time Programming access to meter parametersMeter and probe points ManufacturingNormal Mode Diagnostics ModeDisplay Navigation Communications Connections Direct Connection Ethernet RequirementsInjury Network Connection Ethernet Requirements Login screen Configuring the meterConfiguration tool main window Discovered Units dialog box Main configuration window with configured parameters Field Parameter Description Configuration parametersReport Parameters Parameter Description By selecting the check box Daily Minutes PowerLogic E4805 PowerLogic E4833 PowerLogic E4880 List of supported metering configurationsMeter Points Circuits Tab Meter Point ConfigurationBadge Numbering Badge Numbering pane Factor applied to the collected pulse counts Pulse Probes TabE4800 meter is ready to be programmed. Proceed as follows Completing the Meter ConfigurationSending the configured settings to the meter 930-112-01 Schneider Electric USA