This document describes how to configure the the PowerLogic E4800 meter (PowerLogic E4833, E4880 and E4805 meters), using the PowerLogic configuration tool. It includes the following configuration tool information:

“System Set-up and Description” on page 1

“Configuration and Programming” on page 1

“Display Navigation” on page 4

“PowerLogic Configuration Tool” on page 7

“Communications Connections” on page 5

“Configuring the meter” on page 7

“Manufacturing Tab” on page 16

“Meter Points (Circuits) Tab” on page 17

“Pulse Probes Tab” on page 20

“Completing the Meter Configuration” on page 21

 

This documentation is intended for those responsible for configuring the

 

PowerLogic E4833, E4880 and E4805 meters.

System Set-up and Description

The configuration tool supports the PowerLogic E4833, E4880 and E4805

 

meters.

 

Depending on how the meters are installed and configured, they can meter

 

8, 12, or 24 individual meter points. The PowerLogic E4833, E4880 and

 

E4805 meters are designed for residential, commercial, and industrial use

 

and display the power and consumption readings for each measurement

 

point.

Configuration and Programming

The configuration tool is used to change any of the programmable

 

parameters within the PowerLogic E4800 meters. The combination of the

 

configuration tool and the state of the meter programming switches

 

determine which parameters can be changed. As shown in Figure ?, the

 

programming switches are two-position DIP switches labeled SW1, and are

 

located inside the meter cover below the Display button. To enable meter

 

configuration, both switches must be physically set to the ON (down) position

 

(default).

© 2009 Schneider Electric All Rights Reserved

1

Image 7
Contents PowerLogicTM Series E4800 PowerLogicTM E4800 Series 930-112-01 02/2009 Hazard Categories and Special SymbolsPowerLogicTM E4800 Series PowerLogicTM E4800 Series 930-112-01 02/2009 Table of Contents Schneider Electric All Rights Reserved Configuration and Programming Powerlogic E4800 Configuration Tool GuideParameter Read access Write access Activation time Programming access to meter parametersMeter and probe points ManufacturingDiagnostics Mode Normal ModeDisplay Navigation Direct Connection Ethernet Requirements Communications ConnectionsInjury Network Connection Ethernet Requirements Login screen Configuring the meterConfiguration tool main window Discovered Units dialog box Main configuration window with configured parameters Field Parameter Description Configuration parametersReport Parameters Parameter Description By selecting the check box Daily Minutes PowerLogic E4805 PowerLogic E4833 PowerLogic E4880 List of supported metering configurationsMeter Points Circuits Tab Meter Point ConfigurationBadge Numbering Badge Numbering pane Factor applied to the collected pulse counts Pulse Probes TabE4800 meter is ready to be programmed. Proceed as follows Completing the Meter ConfigurationSending the configured settings to the meter 930-112-01 Schneider Electric USA