To install the network cable (refer to Figure 6 on page 13):

1.Run the network cable from a network switch inside the building to the mount site. The equipment must support Gigabit Ethernet operation. NOTE: If you use a junction box or patch panel, make sure the connection is protected from the weather.

2.Install the supplied weatherproof network connector onto the network cable at the mount site (refer to Figure 7):

FERRULE

ADJUSTABLE SEAL

THRUST

WASHER

CAP

NETWORK CABLE AND CONNECTOR

CONNECTOR

SHELL

Figure 7. Assembling the Weatherproof Network Connector

a.Slide the small end of the connector cap onto the network cable.

b.Insert the RJ-45 connector firmly into the connector shell. Make sure the connector locks into place.

c.Snap the ferrule onto the cable between the cap and the connector shell. Make sure the small end of the ferrule points toward the cap.

d.Attach the compression gland to the cable between the ferrule and the connector shell. The gland is multilayered. If the hole is too small, remove the innermost layers one at a time until the gland fits the cable snugly.

e.Attach the thrust washer to the cable between the compression gland and the connector shell.

f.Gently slide the ferrule, gland, and washer into the connector shell.

g.Twist the cap tightly onto the connector shell. If the cap is loose, the connector could fail.

You will connect the weatherproof network connector to the EW5001 later (refer to Unit Installation on page 19).

C2681M (2/08)

15

Image 15
Contents Endura EW5001 Wireless Access Point/Bridge Contents List of Tables List of IllustrationsRegulatory Notices Video Quality CautionExposure to Radio Frequency Fields Optional Accessories DescriptionModels Qty Description Parts ListBefore You Begin USER-SUPPLIED PartsPackage Contents Application Scenarios Sample EW5001 Access Point Application ScenarioSample EW5001 Wireless Bridge Application Scenario IP-TYPE Camera Systems Product Serial Number Label Product Serial Number Label Placement Mount Description Required Adapter Maximum Load Mount Installation Site Preparation Site SelectionPower and Network Wiring Maximum Distance12 VDC 24 VAC AC+ Wire ColorTo install the network cable refer to on POWER-OVER-ETHERNET POE Ferrule Bench Setup Optional Antenna InstallationUnit Installation NUT Lock Washer Weatherproof Network Cable not Supplied Power from Source C2681M 2/08 Close and latch the EW5001 to the J-box Connect all cables refer to FigureOpening the J-BOX Disconnecting AN Antenna CableIndicators Startup PhaseOperation Unit Antenna AlignmentStatus Change Rssi Volts Rssi dBConfiguration Problem Possible Causes Suggested Remedy TroubleshootingSpecifications Esprit pole mount with center feedthrough hole ECM100 Esprit corner mount with center feedthrough holeProduct Warranty and Return Information ISO9001