With the FT85011A transmitter/FR85011A receiver powered off, set the Data Selection switch to the required data communication using a small screwdriver. Refer to Table A for data communication switch settings.

Table A. Data Communication Switch Settings

Data Communication

Switch Setting

 

 

RS-232

0 (default setting)

 

 

RS-422

1

 

 

RS-485 2-Wire

2

 

 

RS-485 4-Wire

3

 

 

Manchester/Bi-Phase

4

 

 

Coaxitron

5

 

 

NOTE: Switch positions 6-9 are not used.

Note the following:

The FT85011A transmitter/FR85011A receiver allows data translation between RS-232 and RS-422 signal levels. Consequently, the Data Selection switch can be set to 0 (RS-232) on the transmitter and to 1 (RS-422) on the receiver. Conversely, the Data Selection switch can be set to 1 (RS-422) on the transmitter and to 0 (RS-232) on the receiver.

If you wish to change the data communication setting after the FT85011A transmitter/ FR85011A receiver has been powered on, power off the transmitter/receiver, change the data communication setting, and then power on the transmitter/receiver again.

C2604M (7/06)

13

Image 13
Contents Fiber Transmitter Receiver Page List of Illustrations ContentsList of Tables Important Safety Instructions Risk of Electric Shock Do not Open Radio and Television Interference Regulatory NoticesDescription Product OverviewAddition, note the following Multimode Models ModelsSingle-Mode Models Data TX LED Data RX LED Video Present LED Front PanelRear Panel Package Contents InstallationData Communication Setup Data Communication Switch Setting Mounting the TRANSMITTER/RECEIVER Into a Rack MountingMounting the Transmitter/Receiver Using the Wall Clip Connections Figures 7-12 for Wiring Diagrams Coaxial CableBi-Phase WirePin RS-485 RS-232 RS-422RS-232 Data Communication Wiring Device a Receiver RS-485 2-Wire Half Duplex Data Communication Wiring RS-485 4-Wire Full Duplex Data Communication Wiring Manchester Data Communication Wiring Bi-Phase Data Communication Wiring Video Present LED TroubleshootingSpecifications Meaning Possible Cause Corrective Action Optic Fault LEDData Rx LED Meaning Possible Cause Corrective Action Data Tx LEDVideo SpecificationsCompatible Model No Optical Maximum LaserReceivers Wavelength Receiver Model No Optical Maximum Laser FR85011AC2604M 7/06 Product Warranty and Return Information ISO9001