Pelco FR85011A manual Connections, Figures 7-12 for Wiring Diagrams Coaxial Cable

Page 16

CONNECTIONS

Connections to the FT85011A transmitter and the FR85011A receiver are made on the rear panel of the modules and consist of the following:

Power connection

NOTES:

A 12 VDC or 24 VAC power supply can be used to power the transmitter/receiver when used as a stand-alone module. A 12 VDC power supply is provided. If a 24 VAC power supply is used, the power supply must be a Listed Direct Plug-In Power Unit marked as Class 2 and rated as 24 VAC, 300 mA (minimum output).

In extreme temperature conditions, it is recommended that an industrial-rated outdoor power supply such as the Pelco WCS1-4 power supply be used.

Fiber connection

Data connection

Video input connection (transmitter only)

Video output connection (receiver only)

Figure 6 provides an illustration of FT85011A transmitter/FR85011A receiver connections.

1

2

3

4

5

6

7

8 GND

1 2

3

4

0

 

 

5

9

8

7

6

POWER/ALARM CONNECTION

FOR RACK-MOUNTED MODULE

POWER CONNECTION

FOR STAND-ALONE MODULE

FIBER OPTIC CABLE

DATA COMMUNICATION

CABLE (REFER TO TABLE B

FOR DATA CONNECTOR

PIN ASSIGNMENTS AND TO

FIGURES 7-12 FOR WIRING

DIAGRAMS)

COAXIAL CABLE

Figure 6. FT85011A Transmitter/FR85011A Receiver Connections

16

C2604M (7/06)

Image 16
Contents Fiber Transmitter Receiver Page List of Illustrations ContentsList of Tables Important Safety Instructions Risk of Electric Shock Do not Open Regulatory Notices Radio and Television InterferenceProduct Overview DescriptionAddition, note the following Multimode Models ModelsSingle-Mode Models Front Panel Data TX LED Data RX LED Video Present LEDRear Panel Package Contents InstallationData Communication Setup Data Communication Switch Setting Mounting Mounting the TRANSMITTER/RECEIVER Into a RackMounting the Transmitter/Receiver Using the Wall Clip Figures 7-12 for Wiring Diagrams Coaxial Cable ConnectionsWire Bi-PhasePin RS-485 RS-232 RS-422RS-232 Data Communication Wiring Device a Receiver RS-485 2-Wire Half Duplex Data Communication Wiring RS-485 4-Wire Full Duplex Data Communication Wiring Manchester Data Communication Wiring Bi-Phase Data Communication Wiring Troubleshooting Video Present LEDMeaning Possible Cause Corrective Action Optic Fault LED SpecificationsMeaning Possible Cause Corrective Action Data Tx LED Data Rx LEDSpecifications VideoCompatible Model No Optical Maximum LaserReceivers Wavelength Model No Optical Maximum Laser FR85011A ReceiverC2604M 7/06 Product Warranty and Return Information ISO9001