Pelco C2624M manual Meaning Possible Cause Corrective Action Optic Fault LED

Page 25

Table C. Troubleshooting with Front-Panel Indicators (Continued)

Indicator Color

Meaning

Possible Cause

Corrective Action

 

 

 

 

 

 

Optic Fault LED (

)

 

 

 

 

 

 

Green

The optical signal is

 

No action required.

 

being received and

 

 

 

 

laser is operating

 

 

 

 

properly.

 

 

 

Red

The optical signal is

Remote module is not

Check power connections.

 

not being received.

powered on.

 

Replace power supply if

 

 

 

 

necessary.

 

 

 

 

 

 

Fiber optic cable is not

Check fiber optic

 

 

connected.

 

connections.

 

 

 

 

 

 

Fiber optic cable connectors

Clean, polish, or replace fiber

 

 

are dirty or are damaged.

optic cable connectors as

 

 

 

 

necessary.

 

 

 

 

 

 

 

Fiber optic cable is

 

Replace cable.

 

 

defective.

 

 

 

 

 

 

 

 

Optical dB losses in the

Check for problems with the

 

 

fiber optic installation

fiber optic installation, for

 

 

exceed the optical power

example, excessive dB

 

 

budget specification stated

losses in connectors, splices,

 

 

in the Specifications

patch panels, cables,

 

 

section.

 

and so on.

 

 

 

 

 

 

Optical dB losses in the

Contact Product Support.

 

 

fiber optic installation meet

 

 

 

the optical power budget

 

 

 

specification stated in the

 

 

 

Specifications section;

 

 

 

however, a module is

 

 

 

defective.

 

 

 

 

 

 

Flashing red

Laser has shut down.

Module is operating in

Ensure that module operates

 

 

extreme environmental

according to operating

 

 

conditions; for example,

conditions stated in the

 

 

operating temperature is

Specifications section, and

 

 

below or above recom-

then cycle the power.

 

 

mended range as stated in

If problem persists, contact

 

 

the Specifications section.

Product Support.

 

 

 

 

 

 

Laser has reached end of

Cycle the power. If problem

 

 

life.

 

persists, contact Product

 

 

 

 

Support.

 

 

 

 

 

C2624M (6/07)

25

Image 25 Contents
Ethernet Switch List of Illustrations ContentsRJ-45MDI/MDI-X Connector Pinouts FX Mode Switch SettingsList of Tables Important Safety Instructions Risk of Electric Shock Do not Open Radio and Television Interference Regulatory NoticesDescription Product OverviewC2624M 6/07 FX82012 module consists of the following series of models ModelsMultimode Models Single-Mode Models*†Illustrates the front panel of the FX82012 module Front PanelIllustrates the rear panel of the FX82012 module Rear PanelPackage Contents InstallationFlow control is disabled by default Autonegotiation is enabled by defaultFlow control default setting 10BASE-T/100BASE-TX Modes of OperationFX Mode Switch Setting Fiber Failover ModeMounting Mode of OperationMounting the FX82012 Module to a Wall PAN Head with Wall Clip Lock Washer Connections Fiber connections Primary Fiber Port Connections in Sample Drop-and-Repeat Application Module Reseat module or power Supply as necessary TroubleshootingReplace power supply Meaning Optic Fault LED on local Section in this table Indication Fefi On local module Optical signalReplace local module By the remote linkMeaning Possible Cause Corrective Action Optic Fault LED Amber Table D. Troubleshooting with Rear-Panel IndicatorsIf 10BASE-T operation is EstablishedMeaning Possible Cause Corrective Action Refer to the Setting Duplex mode LinkIf half-duplex mode is Amber Port is set toFull-duplex operation is not Green Port is set to If 100BASE-TX full-duplexFlashing green Port is set to Tion or by manuallyTable D. Troubleshooting with Rear-Panel Indicators Specifications Wavelength Optical Maximum PowerBudget Multimode 62.5/125 μmIllustrates RJ-45 MDI/MDI-X connector pinouts Appendix. RJ-45 Connector PinoutsC2624M 6/07 Product Warranty and Return Information ISO9001