The FX82012 module can be mounted to a wall in the following ways:

Using the supplied wall clip for attachment of a single module to a wall. For installation instructions, refer to the Mounting the FX82012 Module Using the Wall Clip section.

Using the optional WM5001 wall mount kits, which are designed for mounting of single-width fiber optic modules. The WM5001-3U base kit allows mounting of a single module to a wall. The WM5001-3UEXP expansion kit allows mounting of an additional module. It is recommended that a maximum of three expansion kits be used with the base kit, allowing a maximum of four single-width modules to be mounted to a wall.

NOTE: The WM5001 wall mount kits can be used with the WM5002 wall mount kits, which are designed for mounting of double-width fiber optic modules. If mounting a mix of single-width and double-width modules is desired, it is recommended that a maximum of two single-width modules and one double-width module be mounted in combination with one another.

For mounting instructions using the wall mount kits, refer to the WM5000 Series Wall Mount Kit Installation manual.

Mounting the FX82012 Module Using the Wall Clip

NOTE: Before mounting the FX82012 module to a wall, ensure that there is adequate space at both ends for viewing the front-panel LEDs and for making the various rear-panel cable connections.

To attach the FX82012 module to a wall using the supplied wall clip, refer to Figure 7 and do the following:

1.Using the two vertical or horizontal wall-mounting holes, attach the wall clip to a wall using two screws (not provided).

2.Slide the module into the clip until the two holes on the bottom of the module align with the two holes on the lower flange of the clip.

3.Attach the module to the clip using the two Phillips pan head screws provided for the clip.

16

C2624M (6/07)

Image 16
Contents Ethernet Switch Contents List of IllustrationsRJ-45MDI/MDI-X Connector Pinouts FX Mode Switch SettingsList of Tables Important Safety Instructions Risk of Electric Shock Do not Open Regulatory Notices Radio and Television InterferenceProduct Overview DescriptionC2624M 6/07 Models FX82012 module consists of the following series of modelsMultimode Models Single-Mode Models*†Front Panel Illustrates the front panel of the FX82012 moduleRear Panel Illustrates the rear panel of the FX82012 moduleInstallation Package ContentsAutonegotiation is enabled by default Flow control is disabled by defaultFlow control default setting 10BASE-T/100BASE-TX Modes of OperationSetting Fiber Failover Mode FX Mode SwitchMode of Operation MountingMounting the FX82012 Module to a Wall PAN Head with Wall Clip Lock Washer Connections Fiber connections Primary Fiber Port Connections in Sample Drop-and-Repeat Application Module Reseat module or power Supply as necessary TroubleshootingReplace power supply Meaning Indication Fefi On local module Optical signal Optic Fault LED on local Section in this tableReplace local module By the remote linkMeaning Possible Cause Corrective Action Optic Fault LED Table D. Troubleshooting with Rear-Panel Indicators AmberIf 10BASE-T operation is EstablishedMeaning Possible Cause Corrective Action Duplex mode Link Refer to the SettingIf half-duplex mode is Amber Port is set toGreen Port is set to If 100BASE-TX full-duplex Full-duplex operation is notFlashing green Port is set to Tion or by manuallyTable D. Troubleshooting with Rear-Panel Indicators Specifications Power Wavelength Optical MaximumBudget Multimode 62.5/125 μmAppendix. RJ-45 Connector Pinouts Illustrates RJ-45 MDI/MDI-X connector pinoutsC2624M 6/07 Product Warranty and Return Information ISO9001