Pelco C2624M manual Wavelength Optical Maximum, Power, Budget, Multimode 62.5/125 μm

Page 32

OPTICAL POWER BUDGET AND MAXIMUM TRANSMISSION DISTANCE

 

 

Wavelength

Optical

Maximum

 

 

(Transmit/Receive)*

 

Number

Power

Transmission

 

 

 

Model Number

of Fibers

Fiber Port A

Fiber Port B

Budget

Distance

 

 

 

 

 

 

 

 

Multimode (62.5/125 μm)

 

 

 

 

 

 

 

 

FX82012MSTR-2

2 (1 per port)

1310/850 nm

850/1310 nm

26 dB

2 km (1.2 mi)

FX82012MSCR-2

2 (1 per port)

1310/850 nm

850/1310 nm

26 dB

2 km (1.2 mi)

 

 

Single-Mode (9/125 μm)

 

 

 

 

 

 

 

 

FX82012SSTR-2

2 (1 per port)

1310/1550 nm

1550/1310 nm

28 dB

46 km (28.6 mi)§

FX82012SSCR-2

2 (1 per port)

1310/1550 nm

1550/1310 nm

28 dB

46 km (28.6 mi)§

* The FX82012 module is classified by the FDA as a Class 1 laser product. For 850 nm, the Class 1 laser limit is <0.78 mW. For 1310 nm, the Class 1 laser limit is <15.6 mW. For 1550 nm, the Class 1 laser limit is <10.0 mW.

When using 50/125 μm multimode fiber, subtract 3 dB from the optical power budget.

Maximum transmission distance is limited by fiber bandwidth.

§ Maximum transmission distance is based on attenuation of 0.5 dB/km plus a 5 dB buffer for connector and splice losses.

NOTES:

Single-mode FC connectors are available upon request. Contact the factory for additional information.

For conformal coated models, replace the first letter F in the model number with the letter C. The conformal coated version of FX82012MSTR-2, for example, is CX82012MSTR-2.

For models with higher optical power budgets, contact the factory.

32

C2624M (6/07)

Image 32 Contents
Ethernet Switch Contents List of IllustrationsList of Tables FX Mode Switch SettingsRJ-45MDI/MDI-X Connector Pinouts Important Safety Instructions Risk of Electric Shock Do not Open Regulatory Notices Radio and Television InterferenceProduct Overview DescriptionC2624M 6/07 Models FX82012 module consists of the following series of modelsMultimode Models Single-Mode Models*†Front Panel Illustrates the front panel of the FX82012 moduleRear Panel Illustrates the rear panel of the FX82012 moduleInstallation Package ContentsAutonegotiation is enabled by default Flow control is disabled by defaultFlow control default setting 10BASE-T/100BASE-TX Modes of OperationSetting Fiber Failover Mode FX Mode SwitchMode of Operation MountingMounting the FX82012 Module to a Wall PAN Head with Wall Clip Lock Washer Connections Fiber connections Primary Fiber Port Connections in Sample Drop-and-Repeat Application Replace power supply TroubleshootingModule Reseat module or power Supply as necessary Meaning Indication Fefi On local module Optical signal Optic Fault LED on local Section in this tableReplace local module By the remote linkMeaning Possible Cause Corrective Action Optic Fault LED Table D. Troubleshooting with Rear-Panel Indicators AmberIf 10BASE-T operation is EstablishedMeaning Possible Cause Corrective Action Duplex mode Link Refer to the SettingIf half-duplex mode is Amber Port is set toGreen Port is set to If 100BASE-TX full-duplex Full-duplex operation is notFlashing green Port is set to Tion or by manuallyTable D. Troubleshooting with Rear-Panel Indicators Specifications Power Wavelength Optical MaximumBudget Multimode 62.5/125 μmAppendix. RJ-45 Connector Pinouts Illustrates RJ-45 MDI/MDI-X connector pinoutsC2624M 6/07 Product Warranty and Return Information ISO9001