Pelco C2624M Table D. Troubleshooting with Rear-Panel Indicators, Amber, If 10BASE-T operation is

Page 26

Table D. Troubleshooting with Rear-Panel Indicators

Indicator Color

Meaning

Possible Cause

Corrective Action

 

 

 

 

RJ-45 10BASE-T/100BASE-TX Port Status LED - Left (Link/Activity)

 

 

 

 

Amber

A 10BASE-T link is

If 10BASE-T operation is

 

established.

 

desired, no action is required.

 

 

 

If 10BASE-T operation is not

 

 

 

desired, refer to the Setting

 

 

 

10BASE-T/100BASE-TX Port

 

 

 

Modes of Operation section in

 

 

 

this manual for information.

 

 

 

 

Flashing amber

Data activity is

If 10BASE-T operation is

 

occurring on the

 

desired, no action is required.

 

10BASE-T link—

 

If 10BASE-T operation is not

 

data is being trans-

 

desired, refer to the Setting

 

mitted or received.

 

10BASE-T/100BASE-TX Port

 

 

 

Modes of Operation section in

 

 

 

this manual for information.

 

 

 

 

Green

A 100BASE-TX link

If 100BASE-TX operation is

 

is established.

 

desired, no action is required.

 

 

 

If 100BASE-TX operation is

 

 

 

not desired, refer to the

 

 

 

Setting 10BASE-T/

 

 

 

100BASE-TX Port Modes of

 

 

 

Operation section in this

 

 

 

manual for information.

 

 

 

 

Flashing green

Data activity is

If 100BASE-TX operation is

 

occurring on the

 

desired, no action is required.

 

100BASE-TX link—

 

If 100BASE-TX operation is

 

data is being trans-

 

not desired, refer to the

 

mitted or received.

 

Setting 10BASE-T/

 

 

 

100BASE-TX Port Modes of

 

 

 

Operation section in this

 

 

 

manual for information.

 

 

 

 

 

 

 

(Continued on next page)

26

C2624M (6/07)

Image 26 Contents
Ethernet Switch Contents List of IllustrationsList of Tables FX Mode Switch SettingsRJ-45MDI/MDI-X Connector Pinouts Important Safety Instructions Risk of Electric Shock Do not Open Regulatory Notices Radio and Television InterferenceProduct Overview DescriptionC2624M 6/07 Multimode Models ModelsFX82012 module consists of the following series of models Single-Mode Models*†Front Panel Illustrates the front panel of the FX82012 moduleRear Panel Illustrates the rear panel of the FX82012 moduleInstallation Package ContentsFlow control default setting Autonegotiation is enabled by defaultFlow control is disabled by default 10BASE-T/100BASE-TX Modes of OperationSetting Fiber Failover Mode FX Mode SwitchMode of Operation MountingMounting the FX82012 Module to a Wall PAN Head with Wall Clip Lock Washer Connections Fiber connections Primary Fiber Port Connections in Sample Drop-and-Repeat Application Replace power supply TroubleshootingModule Reseat module or power Supply as necessary Meaning Replace local module Indication Fefi On local module Optical signalOptic Fault LED on local Section in this table By the remote linkMeaning Possible Cause Corrective Action Optic Fault LED If 10BASE-T operation is Table D. Troubleshooting with Rear-Panel IndicatorsAmber EstablishedMeaning Possible Cause Corrective Action If half-duplex mode is Duplex mode LinkRefer to the Setting Amber Port is set toFlashing green Port is set to Green Port is set to If 100BASE-TX full-duplexFull-duplex operation is not Tion or by manuallyTable D. Troubleshooting with Rear-Panel Indicators Specifications Budget PowerWavelength Optical Maximum Multimode 62.5/125 μmAppendix. RJ-45 Connector Pinouts Illustrates RJ-45 MDI/MDI-X connector pinoutsC2624M 6/07 Product Warranty and Return Information ISO9001