Sun Microsystems CP32x0 Connectors and Pin Assignments, 1shows the location of the connectors

Page 58

4.2.6FRU PROM

The ARTM-HD contains an IPMI FRU Prom compatible with the ATCA specifications.

4.3Connectors and Pin Assignments

FIGURE 4-1shows the location of the connectors.

FIGURE 4-1Netra CP32x0 ARTM-HD Connectors

8

1

- Serial port

5

- Hard disk drive(s) (single drive contains a

 

 

filler panel on the second drive)

2

- 10/100/1000 Mb Management port

6

- RTM alignment pin

3

- External SAS port (secondary)

7

- Power connector

4

- External SAS port (primary)

8

- Zone 3 connectors

4-4Netra CP32x0 SAS Storage Advanced Rear Transition Module HD User’s Guide • January 2009

Image 58
Contents Sun Microsystems, Inc Please Recycle Contents Disk Management 3-1 3.1 RAID Support Index Index-1 Page Figures Page Tables Page Preface How This Document Is OrganizedUsing Unix Commands Shell PromptsTypographic Conventions Related Documentation Third-Party Web Sites Documentation, Support, and TrainingSun Welcomes Your Comments Page Overview Features of the ARTM-HD Picmg Standards Compliance Airflow Cooling RequirementsPressure Drop Rates ARTM-HD Component Diagram 1Netra CP32x0 ARTM-HD ComponentsI/O Interfaces 3Netra CP32x0 ARTM-HD I/O Configurations Hard Disk Drives Hard Disk Drive ControllerExternal SAS Connectors 3Connecting to an External Disk Array4Connecting to Another Artm LEDsSoftware Support LEDsPage Part Number, Serial Number, and FC Address Labels Part number label Serial number labelPage Installation and Service About Installing and Removing ARTM-HD1Installing the Blade Server and ARTM-HD Into the Atca Shelf Installing the ARTM-HD Retention screw Injector/ejector latch 3Holding the ARTM-HD During Installation 4Inserting the ARTM-HD Power on the system, if necessary Removing the ARTM-HD 5Removing the ARTM-HD Installing a Hard Disk Drive Removing a Hard Disk Drive6Jumper setting for red OOS LED P1/P2 Changing the OOS LED ColorReinstall the ARTM-HD Page Disk Management SAS Bios Overview RAID SupportStarting the SAS Bios Configuration Utility Creating a RAID 0 Volume Creating a RAID 1 Volume Creating a RAID 1E Volume Viewing RAID Volume Properties Synchronizing an Array Activating an ArrayDeleting an Array Locating a Disk DrivePage Specifications and Connectors Specifications for the ARTM-HD Physical DimensionsHardware Descriptions Ethernet Management PortConnectors and Pin Assignments 1shows the location of the connectors1 I/O Connectors Serial Port SAS Connectors Zone 3 Connectors 4lists the Zone 3, J31 connector pinouts 6lists the Zone 3, J33 connector pinouts Bios SAS RAID Index