Sun Microsystems X1150A manual Please Recycle

Page 2

Copyright 2003 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, California 95054, U.S.A. All rights reserved.

This product or document is distributed under licenses restricting its use, copying, distribution, and decompilation. No part of this product or document may be reproduced in any form by any means without prior written authorization of Sun and its licensors, if any. Third-party software, including font technology, is copyrighted and licensed from Sun suppliers.

Parts of the product may be derived from Berkeley BSD systems, licensed from the University of California. UNIX is a registered trademark in the U.S. and other countries, exclusively licensed through X/Open Company, Ltd.

Sun, Sun Microsystems, the Sun logo, AnswerBook2, docs.sun.com, SunVTS, OpenBoot, SunSwitch, Sun Blade, Sun Fire, Ultra, Sun Enterprise, Ultra Enterprise, and Solaris are trademarks, registered trademarks, or service marks of Sun Microsystems, Inc. in the U.S. and other countries. All SPARC trademarks are used under license and are trademarks or registered trademarks of SPARC International, Inc. in the U.S. and other countries. Products bearing SPARC trademarks are based upon an architecture developed by Sun Microsystems, Inc. Energy Star Logo® is a registered trademark of EPA. As an Energy Star® Partner, Sun Microsystems, Inc. has determined that this product meets the Energy Star(R) guidelines for energy efficiency.

The OPEN LOOK and Sun™ Graphical User Interface was developed by Sun Microsystems, Inc. for its users and licensees. Sun acknowledges the pioneering efforts of Xerox in researching and developing the concept of visual or graphical user interfaces for the computer industry. Sun holds a non-exclusive license from Xerox to the Xerox Graphical User Interface, which license also covers Sun’s licensees who implement OPEN LOOK GUIs and otherwise comply with Sun’s written license agreements.

Federal Acquisitions: Commercial Software—Government Users Subject to Standard License Terms and Conditions.

DOCUMENTATION IS PROVIDED “AS IS” AND ALL EXPRESS OR IMPLIED CONDITIONS, REPRESENTATIONS AND WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT, ARE DISCLAIMED, EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID.

Copyright 2003 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, California 95054, Etats-Unis. Tous droits réservés.

Ce produit ou document est distribué avec des licences qui en restreignent l’utilisation, la copie, la distribution, et la décompilation. Aucune partie de ce produit ou document ne peut être reproduite sous aucune forme, par quelque moyen que ce soit, sans l’autorisation préalable et écrite de Sun et de ses bailleurs de licence, s’il y en a. Le logiciel détenu par des tiers, et qui comprend la technologie relative aux polices de caractères, est protégé par un copyright et licencié par des fournisseurs de Sun.

Des parties de ce produit pourront être dérivées des systèmes Berkeley BSD licenciés par l’Université de Californie. UNIX est une marque déposée aux Etats-Unis et dans d’autres pays et licenciée exclusivement par X/Open Company, Ltd.

Sun, Sun Microsystems, le logo Sun, AnswerBook2, docs.sun.com, SunVTS, OpenBoot, SunSwitch, Sun Blade, Sun Fire, Ultra, Sun Enterprise, Ultra Enterprise, et Solaris sont des marques de fabrique ou des marques déposées, ou marques de service, de Sun Microsystems, Inc. aux Etats- Unis et dans d’autres pays. Toutes les marques SPARC sont utilisées sous licence et sont des marques de fabrique ou des marques déposées de SPARC International, Inc. aux Etats-Unis et dans d’autres pays. Les produits portant les marques SPARC sont basés sur une architecture développée par Sun Microsystems, Inc.

L’interface d’utilisation graphique OPEN LOOK et Sun™ a été développée par Sun Microsystems, Inc. pour ses utilisateurs et licenciés. Sun reconnaît les efforts de pionniers de Xerox pour la recherche et le développement du concept des interfaces d’utilisation visuelle ou graphique pour l’industrie de l’informatique. Sun détient une licence non exclusive de Xerox sur l’interface d’utilisation graphique Xerox, cette licence couvrant également les licenciés de Sun qui mettent en place l’interface d’utilisation graphique OPEN LOOK et qui en outre se conforment aux licences écrites de Sun.

LA DOCUMENTATION EST FOURNIE “EN L’ETAT” ET TOUTES AUTRES CONDITIONS, DECLARATIONS ET GARANTIES EXPRESSES OU TACITES SONT FORMELLEMENT EXCLUES, DANS LA MESURE AUTORISEE PAR LA LOI APPLICABLE, Y COMPRIS NOTAMMENT TOUTE GARANTIE IMPLICITE RELATIVE A LA QUALITE MARCHANDE, A L’APTITUDE A UNE UTILISATION PARTICULIERE OU A L’ABSENCE DE CONTREFAÇON.

Please

Recycle

Image 2
Contents Sun GigaSwift Ethernet Adapter Installation User’s Guide Please Recycle Regulatory Compliance Statements FCC Class a NoticeICES-003 Class a Notice Avis NMB-003, Classe a Bsmi Class a Notice Page Declaration of Conformity European UnionPage Declaration of Conformity Page Contents Network Configuration Configuring Driver ParametersDiagnostic Software and Troubleshooting Issues Configuring VLANsSpecifications IndexPage Figures Page Tables Performance Sepcifications Preface How This Book Is OrganizedUsing Unix Commands Typographic ConventionsRelated Documentation Accessing Sun Documentation OnlineShell Prompts Sun Welcomes Your Comments Product Overview Hardware OverviewLED Displays Link is in Full Duplex modeSun GigaSwift Ethernet MMF Adapter 1Front Panel Display LEDs for the MMF AdapterSun GigaSwift Ethernet UTP Adapter 2Sun GigaSwift Ethernet UTP Adapter2Front Panel Display LEDs for the UTP Adapter Hardware and Software Requirements Patch RequirementsProduct Features Key Protocols and InterfacesDiagnostic Support Page Installing the Driver Software Become superuser1Files and Directories on the CD-ROM Select the packages you want to install Menu similar to the following displays# showrev -p grep Verifying PatchesPatch version should be -07 or greater Patch version should be -13 or greater Patch version should be -05 or greaterSave the filler panel screw for Step Installing the Adapter Without Dynamic ReconfigurationTo Install the Adapter 1Connecting the Fiber Optic Cable To Verify the Installation 2Cat-5 Twisted-Pair CableOk cd /pci@1f,0/pci@1/network@4 List the network devices on your systemOk show-nets View the.properties file for a list of device properties Ok .propertiesOk setenv local-mac-address? true Setting the local-mac-addressPropertyPhy-typewill have its value assigned as follows Ok boot -r Rebooting the SystemOk setenv boot-device /pci@1f,2000/pci@1/network@4 States and conditions should be Installing the Adapter With Dynamic ReconfigurationTo Install an Adapter in a Dynamic Reconfiguration System # cfgadm# cfgadm -c disconnect sysctrl03 # cfgadm -v -c configure sysctrl#slot## cfgadm -c disconnect sysctrl#slot# # drvconfig devlinks disks ports tapes Configure the adapter and slotReconfigure the devices on the adapter Connect the adapter and slotPage Configuring the Network Host Files Use the ifconfig command to setup the adapter’s ce interface# ifconfig ce0 plumb ipaddress up Export/root/clientname To Set Up a GigaSwift Ethernet Port on a Diskless Client# cat /etc/hosts Edit the hosts in the diskless client’s root directory Network Configuration # cd /cdrom/cdrom0/GigaSwiftEthernet/Packages # ls SUNWce # grep clientname /etc/bootparamsFind the root directory of the client system # shutdown -i0 -g0 -y Use the shutdown command to display the OpenBoot ok promptShut down and halt the client system # pkginfo grep SUNWce Proceed with the Solaris operating environment installationOk boot /pci@1f,4000/network@4speed=100,duplex=full Booting Over the GigaSwift Ethernet Network Ok boot device-pathspeed=s,duplex=d,link-clock=c,promiscuous1Device Link Parameters 2link-clockCapabilities for Link Up# boot netspeed=1000,duplex=auto,link-clock=auto # boot netspeed=100,duplex=full# boot netspeed=1000,duplex=full,link-clock=master Page Configuring Driver Parameters GigaSwift Ethernet Device Driver ParametersDriver Parameter Values and Definitions 1ce Driver Parameter, Status, and DescriptionsOperational Mode Parameters Operational Mode Parameters2Operational Mode Parameters Flow Control Parameters3provides flow control keywords and describes their function 3Read-Write Flow Control Keyword DescriptionsInterpacket Gap Parameters 4Forced Mode ParameterGigabit Link Clock Mastership Controls 5Parameters Defining enable-ipg0and ipg0 7RX Blanking Register for Alias Read Interrupt Parameters7describes the receive interrupt blanking values Random Early Drop Parameters 8RX Random Early Detecting 8-Bit VectorsPCI Bus Interface Parameters 9PCI Bus Interface ParametersSetting ce Driver Parameters Setting Parameters Using the ndd UtilityDevice remains selected until you change the selection To Specify Device Instances for the ndd UtilityUse the instance number to select the device # ndd -set /dev/ce instance instance## ndd -set /dev/ce parameter value To modify a parameter value, use the -setoptionNdd utility then prompts you for the name of the parameter # ndd /dev/ce parameterSetting the Autonegotiation Mode # ndd -set /dev/ce adv-autoneg-cap Setting Parameters Using the ce.conf FileSet the adv-autoneg-capparameter to # grep ce /etc/pathtoinst To Set Driver Parameters Using a ce.conf FileSecond line in the previous example Save the ce.conf file Usability Enhancements to the DriverThird line in the previous example # ndd -set /dev/hme instance# ndd -get /dev/hme link-status GigaSwift Ethernet Driver Operating StatisticsThen you had to get the link status # kstat cen grep linkup10Read-Only ce Device Capabilities 11Read-Only Link Partner Capabilities Reporting the Link Partner Capabilities11describes the read-only link partner capabilities 12describes the netstat -k transmit and receive parameters 12Transmit and Receive Parameters12Transmit and Receive Parameters # kstat Ce0 Code Example 4-1Output from kstat Command# netstat -k ce0 # kstat ce0 # kstat ce0 Use the kstat command to discover link partner capabilities # kstat ce0 grep lpUse the kstat command to discover link settings # kstat ce0 grep linkPage Configuring VLANs An Overview of VLANs1shows an example network that uses VLANs Configuring VLANs To Configure Static VLANs Vlan logical PPA = 1000 * VID + Device PPA# ifconfig ce123000 plumb up # ifconfig ce224000 plumb up # ifconfig -aPage Connectors Table A-1SC Connector Link Characteristics Ieee P802.3zTable A-3Performance Sepcifications Performance SpecificationsTable A-2Cat-5 Connector Link Characteristics Table A-5Power Requirements Physical CharacteristicsPower Requirements Page Diagnostic Software Troubleshooting Issues SunVTS Diagnostic SoftwareReset the system Using the OpenBoot Prom FCode Self- TestRunning the Ethernet FCode Self-Test Diagnostic Shut down the systemOk test /pci@1f,0/pci@1/network@4 Ok setenv diag-switch? falseType show-netsto display the list of devices Reset and reboot the system Troubleshooting IssuesSet the auto-boot?configuration parameter to true Ok setenv auto-boot? trueType the following to apply and save your changes Adv-pause-capTable B-1Troubleshooting the GigaSwift Ethernet Adapter Failure to Configure GigaSwift Ethernet InstanceNon-Specific Issues Add the following lines to the /etc/system file Problem with DR Attach on Sun Enterprise PlatformsReboot system Set drdetachsafelist1=ce set hswpsuspendsafelist1=cePage Symbols Index