The phy-typewill have its value assigned as follows:

Media type

phy-type

 

 

Fiberpcs

Coppermif

Note If you are going to set the local-mac-addressproperty, note the local-mac-addressof your device at this time. See “Setting the local-mac- address Property” on page 19 for more information.

Setting the local-mac-addressProperty

Note Setting the local-mac-addressproperty is only required if you will be booting from the network.

The network interface of the Sun GigaSwift Ethernet adapter has been assigned a unique media access control (MAC) address that represents the 48-bit Ethernet address for that interface. The OpenBoot firmware reports this MAC address via the local-mac-addressproperty in the device nodes corresponding to the network interface.

A system is not obligated to use this assigned MAC address if it has a system-wide MAC address. In such cases, the system-wide MAC address applies to all network interfaces on the system.

The device driver, or any other adapter utility, can use the network device’s MAC address (local-mac-address) while configuring it. In the Solaris operating environment, you can use the MAC address when booting over the network.

The mac-addressproperty of the network device specifies the network address (system-wide or local-mac-address) used for booting the system. To start using the MAC address assigned to the network interface of the Sun GigaSwift Ethernet adapter, set the NVRAM configuration variable local-mac-address?to true.

ok setenv local-mac-address? true

Chapter 2 Installing the Adapter 19

Image 41
Contents Sun GigaSwift Ethernet Adapter Installation User’s Guide Please Recycle FCC Class a Notice Regulatory Compliance StatementsICES-003 Class a Notice Avis NMB-003, Classe a Bsmi Class a Notice Page European Union Declaration of ConformityPage Declaration of Conformity Page Contents Configuring Driver Parameters Network ConfigurationSpecifications Configuring VLANsDiagnostic Software and Troubleshooting Issues IndexPage Figures Page Tables Performance Sepcifications How This Book Is Organized PrefaceTypographic Conventions Using Unix CommandsRelated Documentation Accessing Sun Documentation OnlineShell Prompts Sun Welcomes Your Comments Hardware Overview Product OverviewSun GigaSwift Ethernet MMF Adapter Link is in Full Duplex modeLED Displays 1Front Panel Display LEDs for the MMF Adapter2Sun GigaSwift Ethernet UTP Adapter Sun GigaSwift Ethernet UTP Adapter2Front Panel Display LEDs for the UTP Adapter Patch Requirements Hardware and Software RequirementsKey Protocols and Interfaces Product FeaturesDiagnostic Support Page Become superuser Installing the Driver Software1Files and Directories on the CD-ROM Menu similar to the following displays Select the packages you want to install# showrev -p grep Verifying PatchesPatch version should be -07 or greater Patch version should be -05 or greater Patch version should be -13 or greaterSave the filler panel screw for Step Installing the Adapter Without Dynamic ReconfigurationTo Install the Adapter 1Connecting the Fiber Optic Cable 2Cat-5 Twisted-Pair Cable To Verify the InstallationOk cd /pci@1f,0/pci@1/network@4 List the network devices on your systemOk show-nets Ok .properties View the.properties file for a list of device propertiesOk setenv local-mac-address? true Setting the local-mac-addressPropertyPhy-typewill have its value assigned as follows Ok boot -r Rebooting the SystemOk setenv boot-device /pci@1f,2000/pci@1/network@4 To Install an Adapter in a Dynamic Reconfiguration System Installing the Adapter With Dynamic ReconfigurationStates and conditions should be # cfgadm# cfgadm -c disconnect sysctrl03 # cfgadm -v -c configure sysctrl#slot## cfgadm -c disconnect sysctrl#slot# Reconfigure the devices on the adapter Configure the adapter and slot# drvconfig devlinks disks ports tapes Connect the adapter and slotPage Use the ifconfig command to setup the adapter’s ce interface Configuring the Network Host Files# ifconfig ce0 plumb ipaddress up Export/root/clientname To Set Up a GigaSwift Ethernet Port on a Diskless Client# cat /etc/hosts Edit the hosts in the diskless client’s root directory Network Configuration # cd /cdrom/cdrom0/GigaSwiftEthernet/Packages # ls SUNWce # grep clientname /etc/bootparamsFind the root directory of the client system # shutdown -i0 -g0 -y Use the shutdown command to display the OpenBoot ok promptShut down and halt the client system # pkginfo grep SUNWce Proceed with the Solaris operating environment installationOk boot /pci@1f,4000/network@4speed=100,duplex=full Ok boot device-pathspeed=s,duplex=d,link-clock=c,promiscuous Booting Over the GigaSwift Ethernet Network2link-clockCapabilities for Link Up 1Device Link Parameters# boot netspeed=1000,duplex=auto,link-clock=auto # boot netspeed=100,duplex=full# boot netspeed=1000,duplex=full,link-clock=master Page GigaSwift Ethernet Device Driver Parameters Configuring Driver Parameters1ce Driver Parameter, Status, and Descriptions Driver Parameter Values and DefinitionsOperational Mode Parameters Operational Mode ParametersFlow Control Parameters 2Operational Mode Parameters3Read-Write Flow Control Keyword Descriptions 3provides flow control keywords and describes their functionInterpacket Gap Parameters 4Forced Mode ParameterGigabit Link Clock Mastership Controls 5Parameters Defining enable-ipg0and ipg0 7RX Blanking Register for Alias Read Interrupt Parameters7describes the receive interrupt blanking values 8RX Random Early Detecting 8-Bit Vectors Random Early Drop Parameters9PCI Bus Interface Parameters PCI Bus Interface ParametersSetting Parameters Using the ndd Utility Setting ce Driver ParametersUse the instance number to select the device To Specify Device Instances for the ndd UtilityDevice remains selected until you change the selection # ndd -set /dev/ce instance instance#Ndd utility then prompts you for the name of the parameter To modify a parameter value, use the -setoption# ndd -set /dev/ce parameter value # ndd /dev/ce parameterSetting the Autonegotiation Mode # ndd -set /dev/ce adv-autoneg-cap Setting Parameters Using the ce.conf FileSet the adv-autoneg-capparameter to # grep ce /etc/pathtoinst To Set Driver Parameters Using a ce.conf FileSecond line in the previous example Third line in the previous example Usability Enhancements to the DriverSave the ce.conf file # ndd -set /dev/hme instanceThen you had to get the link status GigaSwift Ethernet Driver Operating Statistics# ndd -get /dev/hme link-status # kstat cen grep linkup10Read-Only ce Device Capabilities 11Read-Only Link Partner Capabilities Reporting the Link Partner Capabilities11describes the read-only link partner capabilities 12Transmit and Receive Parameters 12describes the netstat -k transmit and receive parameters12Transmit and Receive Parameters # kstat Ce0 Code Example 4-1Output from kstat Command# netstat -k ce0 # kstat ce0 # kstat ce0 # kstat ce0 grep lp Use the kstat command to discover link partner capabilities# kstat ce0 grep link Use the kstat command to discover link settingsPage An Overview of VLANs Configuring VLANs1shows an example network that uses VLANs Configuring VLANs Vlan logical PPA = 1000 * VID + Device PPA To Configure Static VLANs# ifconfig -a # ifconfig ce123000 plumb up # ifconfig ce224000 plumb upPage Table A-1SC Connector Link Characteristics Ieee P802.3z ConnectorsTable A-3Performance Sepcifications Performance SpecificationsTable A-2Cat-5 Connector Link Characteristics Table A-5Power Requirements Physical CharacteristicsPower Requirements Page SunVTS Diagnostic Software Diagnostic Software Troubleshooting IssuesRunning the Ethernet FCode Self-Test Diagnostic Using the OpenBoot Prom FCode Self- TestReset the system Shut down the systemOk test /pci@1f,0/pci@1/network@4 Ok setenv diag-switch? falseType show-netsto display the list of devices Set the auto-boot?configuration parameter to true Troubleshooting IssuesReset and reboot the system Ok setenv auto-boot? trueAdv-pause-cap Type the following to apply and save your changesTable B-1Troubleshooting the GigaSwift Ethernet Adapter Failure to Configure GigaSwift Ethernet InstanceNon-Specific Issues Reboot system Problem with DR Attach on Sun Enterprise PlatformsAdd the following lines to the /etc/system file Set drdetachsafelist1=ce set hswpsuspendsafelist1=cePage Index Symbols