Sun Microsystems 806-2989-10 manual Interrupt Parameters, Random Early Drop Parameters

Page 51

Interrupt Parameters

TABLE 4-7describes the receive interrupt blanking values.

TABLE 4-7RX Blanking Register for Alias Read

Field Name

Values

Description

 

 

 

rx_intr_pkts

0 to 511

Interrupt after this number of packets have arrived since

 

 

the last packet was serviced. A value of zero indicates no

 

 

packet blanking. (Default=3)

rx_intr_time

0 to 524287

Interrupt after 4.5 US ticks have elapsed since the last

 

 

packet was serviced. A value of zero indicates no time

 

 

blanking. (Default=1250)

 

 

 

Random Early Drop Parameters

TABLE 4-8describes the RX random early detection 8-bit vectors, which allows you to enable random early drop (RED) thresholds. When received packets reach the RED range packets are dropped according to the preset probability. The probability should increase when the fifo level increases. Control packets are never dropped and are not counted in the statistics.

TABLE 4-8RX Random Early Detecting 8-Bit Vectors

Field Name

Values

Description

 

 

 

red_dv4to6k

0 to 255

Random early detection and packet drop vectors for

 

 

when fifo threshold is greater than 4096 bytes and less

 

 

than 6,144 bytes. Probability of drop can be

 

 

programmed on a 12.5 percent granularity. For

 

 

example, if bit 0 is set the first packet out of every eight

 

 

will be dropped in this region. (Default=0)

 

 

 

Chapter 4 Configuring Driver Parameters 31

Image 51
Contents Sun GigaSwift Ethernet Adapter Installation User’s Guide Please Recycle Regulatory Compliance Statements FCC Class a NoticeFCC Class B Notice ICES-003 Class B Notice Avis NMB-003, Classe B ICES-003 Class a Notice Avis NMB-003, Classe aBsmi Class a Notice Page Declaration of Conformity Product NameSun GigaSwift Ethernet UTP Adapter X1150AEN550221998 / CISPR221997 Page Contents Configuring Driver Parameters Configuring VLANsSpecifications Index Diagnostic Software and Troubleshooting IssuesPage Figures Page Tables Page How This Book Is Organized PrefaceTypographic Conventions Using Unix CommandsAccessing Sun Documentation Online Shell PromptsRelated Documentation Sun Welcomes Your Comments Ordering Sun DocumentationHardware Overview Product Overview1Sun GigaSwift Ethernet UTP Adapter Sun GigaSwift Ethernet UTP AdapterProduct Features Hardware and Software RequirementsKey Protocols and Interfaces Diagnostic Support Installing the Adapter Installing the Driver SoftwareBecome superuser 1Files and Directories on the CD-ROM See -1to identify the optional packages To Install the Adapter Installing the Adapter Without Dynamic Reconfiguration1Cat-5 Twisted-Pair Cable To Verify the InstallationList the network devices on your system Ok .properties View the .properties file for a list of device propertiesTo Set the GigaSwift Ethernet Device Primary Boot Device Setting the local-mac-addressPropertyRebooting the System To Install an Adapter in a Dynamic Reconfiguration System Installing the Adapter With Dynamic ReconfigurationIf the status of the slot is not empty or disconnected, type Configure the adapter and slot Reconfigure the devices on the adapterConnect the adapter and slot Configuring the Network Host Files Network ConfigurationEtc/hostname.ce1 # cat /etc/hosts Edit the hosts in the diskless client’s root directory To Set Up a Diskless Client on a GigaSwift Ethernet NetworkNetwork Configuration Find the root directory of the client system # grep clientname /etc/bootparamsShut down and halt the client system Proceed with the Solaris operating environment installation# pkginfo grep SUNWce GigaSwift Ethernet Device Driver Parameters Configuring Driver Parameters1ce Driver Parameter, Status, and Descriptions Driver Parameter Values and DefinitionsOperational Mode Parameters Operational Mode Parameters3Read-Write Flow Control Keyword Descriptions Flow Control ParametersGigabit Forced Mode Parameter 4Forced Mode ParameterInterpacket Gap Parameters 5Parameters Defining enableipg0 and ipg0 5defines the enableipg0 and ipg0 parameters8RX Random Early Detecting 8-Bit Vectors Interrupt ParametersRandom Early Drop Parameters 7RX Blanking Register for Alias Read9PCI Bus Interface Parameters PCI Bus Interface ParametersSetting Parameters Using the ndd Utility Setting ce Driver ParametersTo Specify Device Instances for the ndd Utility Noninteractive and Interactive ModesUse the instance number to select the device To modify a parameter value, use the -setoption Using the ndd Utility in Interactive ModeSetting the Autonegotiation Mode Setting Parameters Using the ce.conf File To Disable Autonegotiation ModeSet the advautonegcap parameter to Etc/pathtoinst file To Set Driver Parameters Using a ce.conf File10Read-Only ce Device Capabilities GigaSwift Ethernet Driver Operating Statistics11Read-Only Link Partner Capabilities Reporting the Link Partner Capabilities12Transmit and Receive Parameters Rxnewpages rxnewhdrpgs As superuser, type the netstat -kcommand To Check Link Partner SettingsPage An Overview of VLANs Configuring VLANs1shows an example network that uses VLANs Configuring VLANs 2Ethernet Tag Header Format To Configure Static VLANs# ifconfig ce123000 plumb up # ifconfig ce224000 plumb up Page Specifications ConnectorsTable A-1Cat-5 Connector Link Characteristics Table A-2Performance Specifications Performance SpecificationsPhysical Characteristics Power RequirementsSunVTS Diagnostic Software Diagnostic Software Troubleshooting IssuesShut down the system Using the OpenBoot Prom FCode Self- TestRunning the Ethernet FCode Self-Test Diagnostic Reset the systemType show-netsto display the list of devices Troubleshooting Issues Set the auto-boot?configuration parameter to trueReset and reboot the system Type the following to apply and save your changes Adv1000fdxcap Adv1000hdxcap AdvpauseTX AdvpauseRX Index Symbols