METRObility Optical Systems RADIANCE 10/100MBPS ACCESS OPTICAL NETWORK UNIT Input Power Level

Page 16

Singlemode Fiber Optic Power Monitors

Through software*, you can read the input and output power levels of the singlemode fiber optic port on the Access ONU.

Input Power Level

The accuracy of the input power monitor is ±1dBm from -28dBm to -12dBm. The accuracy is ±2dBm from -31dBm to -29dBm. The monitor is unresponsive below -31dBm. If there are no cables connected to the fiber port, the software may display a reading of -40dBm. The Access ONU peaks at -12dBm and reaches saturation at -7dBm.

The singlemode long haul (RA21-17) and extended long haul (RA21-1J) ports are operational down to -34dBm, which is too low for the monitor to measure. If the input power level is between -34dBm and -29dBm, a valid link will be established, however, the light level displayed by the software will show a reading of -40dBm. This reading is not a failure indication; it simply means the level is beyond the range of the power monitor.

 

 

Input Power Monitor

 

 

 

 

 

 

 

Operational

Accurate

 

 

Model #

Monitoring

Trap Thresholds

Failure Reading

Range

 

Range

 

 

 

 

 

 

 

 

 

 

 

RA21-14

-29 to -7dBm

-28 to -12dBm

-28dBm and -7dBm

-31dBm

RA21-16

 

 

 

 

 

 

 

 

 

RA21-17

-34 to -7dBm

-31 to-12dBm

-31dBm and -7dBm

-40dBm

RA21-1J

 

 

 

 

 

 

 

 

 

Output Power Level

The accuracy of the output power monitor is ±3dBm. Failure readings indicate that the unit is non-functional and must be replaced. If there are no cables connected to the fiber port, the software may display readings that indicate failure.

Output Power Monitor

Model #

Operational

Typical

Trap Thresholds

Failure Reading

Range

Reading

 

 

 

 

 

 

 

 

RA21-14

-15 to -8dBm

-11dBm

-15dBm and -7dBm

-18dBm or -3dBm

RA21-16

 

 

 

 

 

 

 

 

 

RA21-17

-5 to 0dBm

-3dBm

-6dBm and 0dBm

-9dBm or +3dBm

RA21-1J

 

 

 

 

 

 

 

 

 

*Refer to the Command Line Interface Reference Guide, NetBeacon Element Management Software Installation & 16User Guide or WebBeacon Management Software Installation & User Guide for software management information.

16 User Guide

Image 16
Contents Installation & User Guide Radiance Access Optical Network Unit 10/100Mbps Copper to FiberInstallation & User Guide Overview Radiance 10/100Mbps Access Optical Network Unit MDI-IIto MDI-XSwitch twisted-pair port only 2Set the Switches1Unpack the Unit Default Settings Duplex Link Loss Carry Forward 3Connect to the NetworkTwisted-Pair Interface 4Apply Power Installation Guide Factory Settings LED IndicatorsDefault Hardware Switch Settings Default Software Settings Software SettingsLoopback Mode Port Enable/DisableRmon Statistics Remote Management StatisticsEthernet Statistics Singlemode Fiber Optic Power Monitors Input Power LevelLink Loss Carry Forward Llcf Link Loss Return LLR Topology Solutions Data Rate Technical SpecificationsNetwork Connections Power EnvironmentalProduct Safety, EMC and Compliance Statements CSAWarranty and Servicing Product Manuals