METRObility Optical Systems RADIANCE 10/100MBPS ACCESS OPTICAL NETWORK UNIT Default Settings

Page 7

Switch

Position

Function

Label

 

 

 

 

 

 

ON

Full duplex is enabled on the TX port, if AUTONEG is OFF.

DUPLEX

(default)

 

 

 

OFF

Half duplex is enabled on the TX port, if AUTONEG is OFF.

 

 

 

 

ON

TX port advertises 100Mbps full-duplex capabilities to its

AUTONEG

(default)

link partner.

 

 

OFF

Auto-negotiation is disabled. Duplex and speed for the TX

 

 

port are set through the DUPLEX and 100M switches.

 

 

 

 

 

 

ON

TX port speed is set to 100Mbps, if AUTONEG if OFF.

100M

(default)

 

 

 

 

OFF

TX port speed is set to 10Mbps, if AUTONEG is OFF.

 

 

 

 

ON

Far End Fault is enabled on the FX port.

FEF

(default)

 

OFF

Far End Fault is disabled on the FX port.

 

 

 

 

ON

Link Loss Return is enabled on the FX port.

LLR

 

 

OFF

Link Loss Return is disabled on the FX port.

 

(default)

 

 

 

 

ON

Link Loss Carry Forward is enabled on the unit.

LLCF

 

 

OFF

Link Loss Carry Forward is disabled on the unit.

 

(default)

 

 

 

DC INPUT/5VDC

Radiance Access Optical Network Unit

ON

Default Settings

OFF

DUPLEXAUTONEG100M

FEF

LLR

LLCF

 

 

 

1

2

3

4

5

6

 

 

 

 

 

DUPLEXAUTONEG100M

FEF

LLR

LLCF

1

2

 

3

4

5

6

 

*DIP switches can also be managed remotely via console commands or through Metrobility’s NetBeacon or WebBeacon management software. Refer to the Command Line Interface Reference Guide, NetBeacon Element Management Software Installation & User Guide or WebBeacon Management Software Installation & User Guide for software management information.

Radiance 10/100Mbps Access Optical Network Unit

7

Image 7
Contents Installation & User Guide 10/100Mbps Copper to Fiber Radiance Access Optical Network UnitInstallation & User Guide Overview Radiance 10/100Mbps Access Optical Network Unit MDI-IIto MDI-XSwitch twisted-pair port only 2Set the Switches1Unpack the Unit Default Settings Duplex 3Connect to the Network Link Loss Carry ForwardTwisted-Pair Interface 4Apply Power Installation Guide Factory Settings LED IndicatorsDefault Hardware Switch Settings Port Enable/Disable Default Software SettingsSoftware Settings Loopback ModeRmon Statistics Remote Management StatisticsEthernet Statistics Input Power Level Singlemode Fiber Optic Power MonitorsLink Loss Carry Forward Llcf Link Loss Return LLR Topology Solutions Data Rate Technical SpecificationsNetwork Connections Environmental PowerCSA Product Safety, EMC and Compliance StatementsWarranty and Servicing Product Manuals