METRObility Optical Systems RADIANCE 10/100MBPS ACCESS OPTICAL NETWORK UNIT Power, Environmental

Page 21

Singlemode F/O Interface — extended long haul distance support (RA21-1J) Connector _____________________________________________________ SC

Wavelength _______________________________________________ 1550 nm

RX Input Sensitivity ________________________________ -34 dBm minimum

Output Power ______________________________________ -5 dBm to 0 dBm

Supported Link Length _________________________ up to 100 km full duplex

Cable Type _______________________________________ 9/125 m SM F/O

Singlemode BWDM Fiber Optic Interface (RA21-1X, RA21-1Y)

Connector _____________________________________________________ SC

Supported Link Length __________________________ up to 20 km full duplex

Cable Type ___________________________________________ 9/125 m F/O

RX Input Sensitivity ________________________________ -32 dBm minimum

Output Power ___________________________ -15 dBm to -8 dBm (9/125 m)

(RA21-1X)

TX Wavelength ________________________________________ 1550 nm

RX Wavelength ________________________________________ 1310 nm

(RA21-1Y)

TX Wavelength ________________________________________ 1310 nm

RX Wavelength ________________________________________ 1550 nm

Power

Input ________________________________________ 90-260 V AC, 50/60 Hz

Output __________________________________ 5 V DC @ 2 A, 10 W average

Environmental

Operating Temperature ____________________________________ 0° to 50° C

Storage Temperature ____________________________________ -30°to 70° C

Operating Humidity _________________________ 5% to 95% non-condensing

Dimensions _________________________________ 4.5" L x 5.75" W x 1.5" H

_______________________________ (11.4 cm x 14.6 cm x 3.8 cm)

Weight _____________________________________________ 1.26 lb (0.57 kg)

Radiance 10/100Mbps Access Optical Network Unit

21

Image 21
Contents Installation & User Guide 10/100Mbps Copper to Fiber Radiance Access Optical Network UnitInstallation & User Guide Overview Radiance 10/100Mbps Access Optical Network Unit 2Set the Switches MDI-IIto MDI-XSwitch twisted-pair port only1Unpack the Unit Default Settings Duplex 3Connect to the Network Link Loss Carry ForwardTwisted-Pair Interface 4Apply Power Installation Guide LED Indicators Factory SettingsDefault Hardware Switch Settings Software Settings Default Software SettingsLoopback Mode Port Enable/DisableRemote Management Statistics Rmon StatisticsEthernet Statistics Input Power Level Singlemode Fiber Optic Power MonitorsLink Loss Carry Forward Llcf Link Loss Return LLR Topology Solutions Technical Specifications Data RateNetwork Connections Environmental PowerCSA Product Safety, EMC and Compliance StatementsWarranty and Servicing Product Manuals