Quatech user manual Device = C\SSP-100\SSP100CL.SYS

Page 13

option. If no number is specified, the SSP-100 will be configured as the next available COM Port using the standard base address and IRQ settings for that COM port. If this option is omitted, the user must either specify a base address or IRQ setting for the SSP-100 or allow Card and Socket Services to select a base address and IRQ to configure the card. When the “A” command is used, the “B”, “I”, and “E” commands must not be used.

2.1.2.1 Example 1

DEVICE = C:\SSP-100\SSP100CL.SYS

In example 1, no command line arguments are specified. The Client Driver will configure a SSP-100 inserted into any socket with a base address and IRQ assigned by Card and Socket Services. The BIOS equipment list will not be updated.

2.1.2.2 Example 2

DEVICE = C:\SSP-100\SSP100CL.SYS (b290,i11)

In example 2, a single command line argument is provided. The Client Driver will attempt to configure a SSP-100 inserted into any socket with a base address of 290H and IRQ 11. The BIOS equipment list will not be updated. If address 290H or IRQ 11 is unavailable, the SSP-100 will not be configured.

2.1.2.3 Example 3

DEVICE = C:\SSP-100\SSP100CL.SYS (s0,b300,i5)

In example 3, a single command line argument is provided. The Client Driver will attempt to configure a SSP-100 inserted into socket 0 with a base address of 300H and IRQ 5. The BIOS equipment list will not be updated. If address 300H or IRQ 5 is unavailable, the SSP-100 will not be configured. In addition, if a SSP-100 is inserted into any other socket, it will not be configured.

2.1.2.4 Example 4

DEVICE = C:\SSP-100\SSP100CL.SYS (i5,b300)

In example 4, a single command line argument is provided. Because the parameter order is not significant, the Client Driver will attempt to configure a SSP-100 inserted into any socket with a base address of 300H and IRQ 5. The BIOS equipment list will not be updated. If address 300H or IRQ 5 is unavailable, the SSP-100 will not be configured.

2.1.2.5 Example 5

SSP-100 User’s Manual

2-4

Image 13
Contents SSP-100 Page Page Warranty Information Declaration of Conformity Table of Contents Page Introduction This page intentionally left blank DOS / Windows 3.x Installation SSP-100 Client Driver for DOS Client Driver InstallationSsocket Command Line OptionsDevice = C\SSP-100\SSP100CL.SYS Device = C\SSP-100\SSP100CL.SYS b300,i5 Device = C\SSP-100\SSP100CL.SYS s0,b300,i5 s1,b340,i10 Generic Client Drivers Common ProblemsSSP-100 Enabler for DOS Option is not used SSP100EN SSP100EN s0,b300,i3,wd8 SSP100EN s0,a3 Memory Range Exclusion This Page Left Intentionally Blank SSP-100 User’s Manual Installing a SSP-100 Under Windows 95, 98, ME Windows 95, 98, 2000, ME, NT InstallationPage Windows 2000 New Hardware Wizard SSP-100 User’s Manual Viewing Resource Settings with Device Manager SSP-100 Resource Settings in WindowsWindows 95, 98,ME Device Manager SSP-100 User’s Manual Windows 2000 Device Manager Changing Resource Setting with Window 2000 Device Manager Windows 95,98,ME Resource Allocation SSP-100 User’s Manual Page Page Basic Configuration List Not Available Installing SSP-100 under Windows NT Page Page Page Windows CE Installing Quatech Pcmcia Cards under Windows CEPage Page OS/2 Installation Configuring With User Assigned Resources Configuring With System Assigned ResourcesDEVICE=C\SSP-100\SSP100.SYS 3,100,5 Advanced Configuration Topics Monitoring The Status Of Pcmcia Cards OS/2 Plug and Play GUI with properly configured SSP-100This Page Left Intentionally Blank SSP-100 Adapter Cable External ConnectionsThis page intentionally left blank Specifications SSP-100