Quatech DSC-300, DSC-200 user manual QTPCI.EXE Basic Mode display

Page 26

The QTPCI program is capable only of displaying the PCI configuration. It

cannot be used to make changes.

Quatech PCI Configuration Information Display Software

Version 1.00

INSTRUCTIONS:

------------------------

Press keys listed in the menu at the bottom of the screen.

This program only displays information. It cannot make changes. Numbers preceeded by "0x" are hexadecimal.

PCI BIOS detected, version 2.10

 

Quatech PCI adapters detected

 

---------------------------------------------

 

DSC-200/300 Two-port RS-422/485 adapter

(Hardware Revision A1)

Uses IRQ 3

 

 

Base addr 1 = 0xffa80

I/O

 

_

 

 

Q - Quatech PCI adapters

M - Change to Expert Mode

N - Other PCI devices

 

X - EXIT

 

Figure 15 --- QTPCI.EXE Basic Mode display

Figure 16 shows the Expert Mode display for the DSC-200/300 after the "Q" key has been pressed. The information from the Basic Mode display is presented along with more details such as the Vendor and Device IDs, PCI Class Code, size of memory and I/O regions, etc. Pressing the "N" key will show similar information for all

Quatech DSC-200/300 User's Manual

26

Image 26
Contents DSC-200/300 Warranty Information Page Declaration of Conformity Manufacturers Name Address Map and Special Registers RS-422 or RS-485 Signal Line TerminationUsing the New Hardware Found Wizard Base Address and Interrupt Level IRQPage General Information Features IND Option --- Surge Suppression UpgradeHardware Configuration Factory default signal termination settingsSignal Connections Full-duplex/Half-duplex OperationEnable Scratchpad Register SPAD, J13 Clock Rate and Optional RegistersForce High-Speed Uart Clock X2, X4, or X8, J10-J12 Clock multiplier jumper optionsHardware Installation Jumper/connector locationsChannel Address Range Enabling the Special Registers Interrupt Status RegisterOptions Register Bit Name DescriptionClock Rate Multiplier RR1 RR0Windows Configuration Windows MillenniumWindows Windows Windows Page Using the New Hardware Found Wizard Windows NT DOS and Other Operating Systems QTPCI.EXEQTPCI.EXE Basic Mode display QTPCI.EXE Expert Mode display OS/2 External Connections Jumper/Channel correspondenceRTS/CTS Handshake RclkXclk AUXIN/AUXOUT LoopbackHalf-Duplex/Full-Duplex Selection Half- or full-duplex selection Termination Resistors RS-422/485 Line termination resistance valuesDSC-200/300 connector definitions RS-422/485 Peripheral ConnectionPCI Resource Map INTA#10Specifications Troubleshooting Computer will not boot upDSC-200/300 Revision June