Quatech DSC-200, DSC-300 user manual Enabling the Special Registers, Interrupt Status Register

Page 15

4.2 Enabling the Special Registers

The DSC-200/300 contains two unique registers, an Interrupt Status Register and an Options Register. These registers are enabled when the SPAD jumper (J13) is removed (factory default). They replace the UART Scratchpad Register on accesses to register address 7.

The Interrupt Status Register and Options Register are accessed through the scratchpad location of any UART. The DLAB bit of the UART (Line Control Register, bit 7) is used to select between the two registers. The most recent write of a DLAB bit in any UART selects between the two registers as shown in Figure 8.

DLAB Bit

SPAD Jumper

Register selected for

address 7 accesses

 

 

0

removed

Interrupt Status Register

1

removed

Options Register

X

applied

Scratchpad Registers

Figure 8 --- DLAB bit selects between special registers

4.3 Interrupt Status Register

The read-only Interrupt Status Register can be used to quickly identify which serial ports require servicing after an interrupt. Reading the Interrupt Status Register will return the interrupt status of the entire DSC-200/300, as shown in Figure 9. The individual bits are cleared as the interrupting ports are serviced. The interrupt service routine should ensure that the interrupt status register reads zero before exiting.

Bit

Description

7 (MSB)

0 (not used)

 

 

6

0 (not used)

 

 

5

0 (not used)

 

 

4

0 (not used)

 

 

3

0 (not used)

 

 

2

0 (not used)

 

 

1

Port 2 --- 1 if interrupt pending

0Port 1 --- 1 if interrupt pending

Figure 9 --- Interrupt Status Register

Quatech DSC-200/300 User's Manual

15

Image 15
Contents DSC-200/300 Warranty Information Page Declaration of Conformity Manufacturers Name Base Address and Interrupt Level IRQ RS-422 or RS-485 Signal Line TerminationUsing the New Hardware Found Wizard Address Map and Special RegistersPage General Information IND Option --- Surge Suppression Upgrade FeaturesFactory default signal termination settings Hardware ConfigurationFull-duplex/Half-duplex Operation Signal ConnectionsClock Rate and Optional Registers Enable Scratchpad Register SPAD, J13Clock multiplier jumper options Force High-Speed Uart Clock X2, X4, or X8, J10-J12Jumper/connector locations Hardware InstallationChannel Address Range Interrupt Status Register Enabling the Special RegistersBit Name Description Options RegisterRR1 RR0 Clock Rate MultiplierWindows Millennium Windows ConfigurationWindows Windows Windows Page Using the New Hardware Found Wizard Windows NT QTPCI.EXE DOS and Other Operating SystemsQTPCI.EXE Basic Mode display QTPCI.EXE Expert Mode display OS/2 Jumper/Channel correspondence External ConnectionsRclk RTS/CTS HandshakeAUXIN/AUXOUT Loopback XclkHalf-Duplex/Full-Duplex Selection Half- or full-duplex selection RS-422/485 Line termination resistance values Termination ResistorsRS-422/485 Peripheral Connection DSC-200/300 connector definitionsINTA# PCI Resource Map10Specifications Computer will not boot up TroubleshootingDSC-200/300 Revision June