Switches S1-6 and S1-7: System Clock Mode
Use Switches
|
| Clock Mode | Description |
|
|
|
|
On | On | Internal | System clock generated internally |
On | Off | Receive Recover | System clock derived from the |
|
|
| received line signal |
|
|
|
|
Off | Off | Hardware Reset |
|
|
|
|
|
| A pair of Model 1082/Is communicate synchronously | |
| ||
| across the twisted pair line connection. Therefore, you | |
| must set these switches whether your application is | |
| async or sync. For Sync or Async applications, please | |
| configure one Model 1082/I for internal clock mode and | |
| the other Model 1082/I for receive recover clock mode. | |
Important | ||
|
Switch S1-8: Response to RDL Request
Use Switch
| Setting |
|
|
On | Response to RDL Request Enabled |
Off | Response to RDL Request Disabled |
|
|
Note The Remote Digital Loopback (RDL) will not work for 144 kbps. You must first set the units to 128 kbps or slower to use the RDL.