Patton electronic 1082, 144, I user manual Switches S1-6 and S1-7 System Clock Mode, S1-8 Setting

Page 14

Switches S1-6 and S1-7: System Clock Mode

Use Switches S1-6 and S1-7 to configure the 1082/I or Model 1082/144/ I for internal, or receive recover clock mode.

S1-6

S1-7

Clock Mode

Description

 

 

 

 

On

On

Internal

System clock generated internally

On

Off

Receive Recover

System clock derived from the

 

 

 

received line signal

 

 

 

 

Off

Off

Hardware Reset

 

 

 

 

 

 

A pair of Model 1082/Is communicate synchronously

 

 

across the twisted pair line connection. Therefore, you

 

must set these switches whether your application is

 

async or sync. For Sync or Async applications, please

 

configure one Model 1082/I for internal clock mode and

 

the other Model 1082/I for receive recover clock mode.

Important

 

Switch S1-8: Response to RDL Request

Use Switch S1-8 to allow Model 1082/I and Model 1082/144/I to enter the Remote Digital Loopback diagnostic test when requested to do so by the far end Model 1082/I and Model 1082/144/I. For example, when switch S1- 8 is set to “ON”, it will enter RDL mode (See section 6.3, “Test Modes” on page 23) when requested to do so by the remote Model 1082/I and Model 1082/144/I.

S1-8

Setting

 

 

On

Response to RDL Request Enabled

Off

Response to RDL Request Disabled

 

 

Note The Remote Digital Loopback (RDL) will not work for 144 kbps. You must first set the units to 128 kbps or slower to use the RDL.

14

Image 14
Contents User Manual Table of Contents Model 1082/I Factory Replacement Parts Accessories CE Notice Warranty InformationFCC Information Service Tel 301 Mailsupport@patton.comFeatures General InformationHTTP/HTML Management 1082 Snmp Management SolutionsDescription PPP Operational Background ApplicationsEthernet LAN Page Configuration Configuring the Hardware DIP SwitchesConfiguring DIP Switch S1 S1 Summary Table Position Function Factory DefaultSwitch S1-5 Asynchronous/Sync Operation Switches S1-1 and S1-2 Data RateS1-3 Setting S1-4 S1-5 SettingSwitch S1-8 Response to RDL Request Switches S1-6 and S1-7 System Clock ModeS1-6 S1-7 Clock Mode Description S1-8 SettingS2-1 Activation Description Configuring DIP switch S2S2 Summary Table Position Function Factory Default Switches S2-3, S2-6, S2-7 and S2-8 Reserved Switch S2-2 Front Panel Switch DisableS2-2 Setting Installation Connecting DSL Interface10Base-T DTE Connecting 10BASE-T Ethernet Port to PC DTEConnecting 10BASE-T Ethernet Port to HUB DCE RJ-45 Pin NoPower Connection Universal AC Power 100-240VACDC Power To Power Supply JackLED Status Monitors POWER-UPOperation LED Test Modes Remote Digital Loopback RDL/V.52 BERPage Connectors DiagnosticsLED Status Indicators PowerWeight Temperature RangeDimensions AltitudeAppendix B Model # Description