Patton electronic 1068 user manual Connecting the TWISTED-PAIR Line Interface

Page 10

6.Connect the Ethernet interface (refer to section 3.4, “Connecting the 10/100Base-T Ethernet Interface” on page 11).

3.3CONNECTING THE TWISTED-PAIR LINE INTERFACE

The VLINK modem supports communication between two peer Ethernet LAN sites over a distance of up to 6,000 ft (1.83 km) over 24 AWG (0.5 mm) twisted-pair wire.

Note Actual distance and link performance may vary depending on the environment and type/gauge of wire used.

Follow the steps below to connect the VLINK modem VDSL interfaces.

Note The VLINK modem units work in pairs. One of the units must be a CO (Central Office), and the other unit must be a CP (Cus- tomer Premise). It does not matter which end is the CO and which is the CP. The link is always initiated by the CP. As long as the CO is powered on, the CP can establish a link by being pow- ered on or by having its power reset.

1.To function properly, the two VLINK modems must be connected together using twisted-pair, unconditioned, dry, metal wire, between 19 (0.9mm) and 26 AWG (0.4mm). Leased circuits that run through signal equalization equipment are not acceptable.

2.The VLINK modem is equipped with two interface jacks that can be used on the VDSL interface, an RJ-45 or a terminal block. These VDSL interfaces are a two-wire interface. Observe the signal/pin rela- tionships on the VLINK modem's VDSL interface jacks.

The RJ-45 connector on the VLINK modem's twisted pair interface is polarity insensitive and is wired for a two-wire interface. The signal/pin relationship is shown in Figure 4.

 

1 (no connection)

1

2 (no connection)

23 (no connection)

4

4

(2-Wire RING)

 

 

5

5

(2-Wire TIP)

6

6 (no connection)

7

7 (no connection)

8

8 (no connection)

Figure 4. VLINK modem (RJ-45) twisted pair line interface.

10

Image 10
Contents User Manual Contents Distance Chart, Based on 24 AWG 0.5 MM Radio and TV Interference FCC Part Warranty InformationCE Declaration of Conformity Tel +1 301 Email support@patton.com ServiceAccessible, and protected by a circuit breaker Feet 3 meters of the device, shall be easilyFeatures General InformationDescription Typical applicationStandalone Unit Installation InstallationVlink Data & Voice 1068 Rack Card Installation 1068RCConnecting the TWISTED-PAIR Line Interface Vlink modem RJ-45 twisted pair line interfaceConnecting the 10/100BASE-T Ethernet Interface Vlink modem 10/100Base-T RJ-45 Connector PinoutConnecting the POTS/ISDN Line Connecting PowerConfiguration Configuring the Hardware DIP SwitchesSwitch toggle S1-1 Setting Configuring DIP Switch S1Switch S1-1 Ethernet Auto Sense Switches S1-2 and S1-4 Data RateS1-2 S1-3 S1-4 Asymmetric Line Rates DS/US S1-5 S1-6 S1-7 S1-8 Reserved for future useOperation Power UPFront Panel LED Status Monitors Description LEDLED is solid yellow and the Vlink Link LED is Off QOL Appendix a LED Status IndicatorsPower Supply LAN ConnectionDimensions Temperature RangeHumidity Appendix B Patton Model # DescriptionPower Cords Vdsl Interface Appendix C10/100BASE-T Interface POTS/ISDN InterfaceSymm Line Rate Distance in feet km Appendix DAsymm Line Rate DS/US Distance in feet km Page Copyright Patton Electronics Company All Rights Reserved