Patton electronic 1068 Configuring DIP Switch S1, Switch S1-1 Ethernet Auto Sense, S1-1 Setting

Page 15

4.2 CONFIGURING DIP SWITCH S1

DIP switch S1 is where you configure the VDSL line rate, symmetric or asymmetric, Ethernet full auto negotiation capability (100Base-T full or half duplex, 10Base-T full or half duplex) or limited auto sense (only 100Base-T half duplex, 10Base-T full or half duplex).

Switch S1-1: Ethernet Auto Sense

Use switch S1-1 to configure the unit for full auto sense capability or lim- ited auto sense capability. Full Auto sense capability consists of standard Ethernet Auto sensing (100BaseT full duplex, 100BaseT half duplex, 10BaseT full duplex, and 10BaseT half duplex). Limited Auto sensing capability consists on only auto sensing for 100BaseT half duplex, 10BaseT full duplex, and 10BaseT half duplex. The limited auto negotia- tion feature is used when an Ethernet device does not comply with IEEE 802.3x (back pressure flow control) at 100M full duplex.

Table 1: Ethernet Auto Negotiation Selection Chart

S1-1

Setting

 

 

OFF

Full Auto Negotiation (Factory Default)

 

(100 Mbps, Full or Half Duplex)

 

(10 Mbps, Full or Half Duplex)

 

 

ON

Limited Auto Negotiation

 

(100 Mbps Half Duplex)

 

10 Mbps Full or Half Duplex)

 

 

Switches S1-2 and S1-4: Data Rate

Use switches S1-2 and S1-4 to configure the VDSL line rates.

Table 2: Symmetric VDSL Line Rates Selection Chart

S1-2

S1-3

S1-4

Symmetric Line Rate

 

 

 

 

ON

ON

ON

6.25 Mbps

ON

ON

OFF

9.38 Mbps

 

 

 

 

ON

OFF

OFF

12.5 Mbps (Factory Default)*

ON

OFF

ON

16.67 Mbps

 

 

 

 

*. Model 1058 only has one symmetric line rate setting, which is 12.5 Mbps.

15

Image 15
Contents User Manual Contents Distance Chart, Based on 24 AWG 0.5 MM Warranty Information Radio and TV Interference FCC PartCE Declaration of Conformity Feet 3 meters of the device, shall be easily ServiceAccessible, and protected by a circuit breaker Tel +1 301 Email support@patton.comGeneral Information FeaturesTypical application DescriptionInstallation Standalone Unit InstallationVlink Data & Voice 1068 1068RC Rack Card InstallationVlink modem RJ-45 twisted pair line interface Connecting the TWISTED-PAIR Line InterfaceVlink modem 10/100Base-T RJ-45 Connector Pinout Connecting the 10/100BASE-T Ethernet InterfaceConnecting Power Connecting the POTS/ISDN LineConfiguring the Hardware DIP Switches ConfigurationSwitch toggle Switches S1-2 and S1-4 Data Rate Configuring DIP Switch S1Switch S1-1 Ethernet Auto Sense S1-1 SettingS1-5 S1-6 S1-7 S1-8 Reserved for future use S1-2 S1-3 S1-4 Asymmetric Line Rates DS/USPower UP OperationFront Panel LED Status Monitors LED DescriptionLED is solid yellow and the Vlink Link LED is Off QOL LAN Connection LED Status IndicatorsPower Supply Appendix aTemperature Range DimensionsHumidity Patton Model # Description Appendix BPower Cords POTS/ISDN Interface Appendix C10/100BASE-T Interface Vdsl InterfaceAppendix D Symm Line Rate Distance in feet kmAsymm Line Rate DS/US Distance in feet km Page Copyright Patton Electronics Company All Rights Reserved