9 • Diagnostics | Model 3086 G.SHDSL Integrated Access Device User Guide |
|
|
1.Go to the 3086 Main page, select E1/T1. Next, click on Test Modes, select local Loop using the drop down menu, click on the Activate Test Mode button.
2.Perform a BER (bit error rate) test. This test can be initiated from the far end using a T1/E1 BER tester to verify the T1/E1 path over the DSL line and 3086s involved.
QRSS—BIT Error Rate Diagnostics
The 3086/K offers a Bit Error Rate (BER) QRSS test pattern. This test pattern may to be used to test the com- munication link and the T1/E1 interface of the device attached to the 3086. When a QRSS test is invoked, the 3086 generates a
To perform a BER test, follow these steps:
1.From the Main page T1/E1 option, select the QRSS or QRSS Errs option, and then click on the Activate Test Mode button. This will start the internal test pattern generator for data sent and looped at the far end device.
2.Monitor the BER test results. The Test Mode Status window will display the number of bit errors, if any, detected in the received stream.
Note The above BER tests will not work if the 3086’s T1/E1 interface has been placed in Network loop.
140 | T1/E1 Diagnostics |