Patton electronic 3086 manual Port Level Configuration Options, 183

Page 183

Model 3086 G.SHDSL Integrated Access Device User Guide

F • Interworking Functions Information

 

 

Port Level Configuration Options:

Ports are used to define the lower level Interworking Functions. The port configuration will define the follow- ing variables:

VPI—Virtual Path Identifier: ATM side Virtual Path Identifier for the specified connection.

VCI—Virtual Channel Identifier: ATM side Virtual Channel Identifier for the specified connection

DE Mapping: The DE Mapping variable is used to determine how the Frame Relay DE field (Discard Eli- gibility) will be mapped to the ATM CLPI (Cell Loss Priority Indication). This variable is only used in the Frame Relay to ATM mapping direction. Note that the DE bit from the core Q.922 (Frame Relay) packet will always be copied unchanged into the FR-SSCS PDU header cell. The following options define how the DE will be mapped to the ATM CLPI bit:

Always_zero: All ATM cells will have the CLPI field set to a constant value of 0.

Always_one: ATM: All ATM cells will have the CLPI field set to a constant value of 1.

Convert: The system will convert the DE field received from the Frame Relay packet into the CLPI field of the outgoing ATM cell that is generated by the segmentation process.

CLPI Mapping: The CLPI Mapping variable is used to determine how the ATM CLPI (Cell Loss Priority Indication) bit in the ATM cell will be mapped to the DE (Discard Eligibility) bit of the resulting Frame Relay packet. There are two options available.

Fr_sscs_only: The FR-SSCS removed from the ATM header PDU is used to set the DE bit in the out- put Frame Relay packet. The CLPI bit from the ATM cell is ignored.

Fr_sscs_and_clpi: Both the DE bit from the ATM header PDU and the CLPI bit from the received ATM cells are used to determine the output state of the resulting Frame Relay packet. The following table defines how .

CLPI received from ATM cell

DE from FR-SSCS of ATM cell

Outgoing DE bit of FR Packet

 

 

 

0

0

0

1

X

1

 

 

 

X

1

1

 

 

 

Multiplexing Mode: The MuxMode variable allows multiple channels to be multiplexed onto a single port. A port is defined by its’ VPI/VCI of the ATM rfc1483 data path. Channels are defined by their Frame Relay DLCI. Thus, the multiplexing mode will allow multiple Frame Relay channels to be transported over a sin- gle ATM VPI/VCI link. There are two options available.

Mux_many_to_one: The “many to one” option allows multiple DLCI channels to be transported over a single ATM rfc1483 connection. Note that if the MuxMode is not set to “many to one” trying to add multiple DLCI connections will result in errors.

Mux_one_to_one: The “one to one” option notifies the system that there will be a one to one mapping between a single ATM port VPI/VCI and a single Frame Relay DLCI.

FRN Name: Allows the user to name the FRN port. This is helpful when viewing multiple connections to determine which VPI/VCI is associated with each port.

Frame Relay Network Interworking (FRF.5)

183

Image 183
Contents Shdsl Integrated Access Device Patton Electronics Company, Inc Contents Basic Application Configurations Contents Specialized Configurations 113 Contacting Patton for assistance 143 Cable Recommendations 157 Contents Page About this guide AudienceStructure Precautions Factory default parameters Safety when working with electricityAbout this guide Typographical conventions used in this document General conventionsMouse conventions General Information Chapter contentsModel 3086 G.SHDSL IAD overview General attributesModel 3086 G.SHDSL IAD overview Protocol support Shdsl CharacteristicsEthernet TDM InterfacePPP Support ATM ProtocolsManagement Model SecurityWAN DSL Rear panel connectors and switches Power connectorConsole port outlined in red RJ-11/4 DSL line port uses pins 2 and 3 of the RJ-11 port Ethernet port outlined in greenLine port outlined in yellow Product Overview Applications Overview Product OverviewProduct Overview Internet/Extranet AccessIP/FR and TDM Access IP/FR and Voice over DSLMetro Intranet Access Quick Start Installation Hardware installation Installing the AC power cordWhat you will need Quick Start Installation Connecting network cablesIP address has now been successfully changed Web Operation and ConfigurationPC Configuration IP address Quick Start modificationModel 3086 menu structure is shown in on Model 3086 home page displays see FigureModel 3086 Menu Structure Basic Application Configurations Basic Application Configurations IPoA Routed RFC Introduction TDM Port Routed WAN Services Bridged WAN ServicesRear panel power and interface connectors Interfaces Connecting the 3086 serial port to a DTEConnecting the 3086 serial port to a DCE X.21 PortsX.21 Ports Configuring the V.35 or X.21 port via DIP switchesDIP switches location Switch Position Function Factory Default Selected Option Switch Bank S2Switch Bank S3 T1 Interface Connection T1 InterfaceDIP Switch Configuration T1 Interface ConfigurationData Rate kbps Figuration only Line Code The 3086 T1 interface uses B8ZS Web Interface ConfigurationE1 Interface Connection E1 InterfaceDescription of S2 options follows the table E1/CRC S3-8 Setting Web Interface Configuration Using the 3086 as a simple modem TDM data over DSL CLI configurationCLI configuration Wait for configuration saved message… Saving configuration… Intended DSL Data Rate Web browser configurationClear Error Counters Circuit IDIntended Serial Interface Data Rate DSL Rate Number of i BitTerminal Type TDM Plus Ethernet Traffic Central or Remote terminal Master/Slave Selecting PCM modeSelecting the DSL link speed Assigning bandwidth to serial and Ethernet portsFor 3086 a at the prompt type For 3086 B typeSelect between Annex a and Annex B To select Annex B type Circuit ID Intended Serial Interface Data Rate Interface Type Ethernet extension Hdlc Pppoh Bridged Using the 3086 in Routed or Bridged applicationsModel 3086 Remote Configuration Steps PPPoH Bridged Two stand-alone units directly connectedLeave User name and Password blank. Click on Apply Model 3086 Central Configuration Steps PPPoH Bridged Network Extension HDLC-PPPoH Routed Model 3086 Remote Configuration Steps PPPoH RoutedModel 3086 G.SHDSL Integrated Access Device User Guide Click on Configure Basic Application Configurations Model 3086 Central Configuration Steps PPPoH Routed Using the 3086 in Routed or Bridged applications Bridged application configurations to a Dslam RFC 1483 Bridged ConfigurationDslam Connections with remote CPE units Model 3086 Remote Configuration Steps RFC 1483 Bridged Model 3086 Central Configuration Steps RFC 1483 Bridged PPPoH Bridged Configuration Dslam Connections with remote CPE units Model 3086 Central Configuration Steps PPPoH Bridged Model 3086 Remote Configuration Steps PPPoA Bridged PPPoA Bridged RFC 2364 ConfigurationVPI = VCI = LLC header mode = off Hdlc header mode = off Model 3086 CentralConfiguration Steps PPPoA BridgedRouted application configurations to a Dslam Model 3086 Remote Configuration Steps RFC 1483 RoutedRFC 1483 Routed Model 3086 G.SHDSL Integrated Access Device User Guide Basic Application Configurations One IP interface was called ip1 with an IP address Model 3086 Central Configuration Steps RFC 1483 RoutedIp set interface ip1 ipaddress 192.168.100.2 Dslam Connections with remote CPE units Basic Application Configurations PPPoH Routed Ip set interface ip1 ipaddress 192.168.100.2 Dslam Connections with remote CPE units Basic Application Configurations Model 3086 Central Configuration Steps PPPoH Routed Basic Application Configurations Basic Application Configurations PPPoA Routed RFC Model 3086 Remote-Client Configuration Steps PPPoA RoutedChap User Namefred Passwoodfredspass Click on ConfigureBasic Application Configurations Dslam Connections with remote CPE units Model 3086 Central-Server Configuration Steps PPPoA Routed 100 101 102 Local IP Magic Number MRU103 104 105 106 Model 3086 Remote Configuration Steps IPoA Routed IPoA Routed RFC107 108 109 110 Model 3086 Central Configuration Steps IPoA Routed VPI0 VCI700 WAN IP address Click on Apply111 112 Specialized Configurations Dhcp Server and Relay IP ConfigurationsRouter RIP and RIPv2 Static Route115 Specialized Configurations116 DNS Client117 DNS Relay ModeIP Configurations Security 120 Configuring the IADConfiguring the security interfaces Security121 122 Deleting a Firewall PolicyFirewall policy named item0 is now deleted Enabling the FirewallFirewall Portfilters Firewall Policies124 Security Triggers125 Scan Attack Block DurationDefault = 86400 seconds Intrusion Detection System IDS126 127 Intrusion Detection System IDS NAT Network Address Translation 130 Enabling NATGlobal address pool and reserved map NAT Network Address Translation131 132 Monitoring Status 134 Status LEDsDiagnostics Ping Software UpgradesConfiguration Procedure137 DiagnosticsOperating Local Analog Loopback LAL-Serial Port Loop Operating Remote Digital Loopback RDL-DSL LoopT1/E1 Diagnostics Network Loop138 139 T1/E1 Local Loop140 QRSS-BIT Error Rate DiagnosticsFDL statistics T1 only AlarmsT1/E1 connection Status Transceiver Status142 BIT Error Rate V.52 DiagnosticsContacting Patton for assistance Returns for credit Warranty coverageOut-of-warranty service Contact informationContacting Patton for assistance Return for credit policyRMA numbers Shipping instructionsPage Appendix a Compliance information CE Declaration of Conformity SafetyCompliance Radio and TV Interference FCC Part149 Authorized European RepresentativeFCC Part 68 Acta Statement Industry Canada Notice150 Appendix B Specifications 152 General CharacteristicsShdsl Characteristics EthernetProtocol Support Sync Serial InterfaceT1/E1 Interface 3086/RIK and RIT models only 64K/G.703 Port 3086/RIF Model154 PPP SupportATM Protocols ManagementCompliance Standard Requirements DimensionsPower and Power Supply Specifications Security156 Appendix C Cable Recommendations Foot 3 m, RJ-11/RJ-11 refer to RJ-11non-shielded port on DSL CableEthernet Cable AdapterAppendix D Physical Connectors RJ-45 non-shielded RS-232 console port EIA-561 Assuming the MDI-X switch is in the out positionRJ-45 shielded 10/100 Ethernet port RJ-11 non-shielded portSerial port 35 M/34 Connector35 DB-25 Female Connector Physical Connectors162 Power input21 DB-15 Connector E1/T1 RJ-48C Connector IEC 320 connector two prong163 Appendix E Command Line Interface CLI OperationRemote Telnet CLI TerminologyProduces a list of numbered transport objects Local VT-100 emulation165 Using the ConsoleCommand Line Interface CLI Operation ThenFollowing information is returned Administering user accountsSetting user passwords Adding new usersShdsl Commands Changing user settingsControlling login access Controlling user accessTo establish the DSL link For CPE remote unit168 169 170 Appendix F Interworking Functions Information Interworking Functions Information 173 LMI Configuration OptionsManagementType Default Value nomaintenance Frame Relay Local Management InterfaceFullReportCycle Default Value MgtAutoStart Default Value FalseT391Value Default Value T392Value Default ValueSet configuration variable CLI Configuration MethodsShow current configuration Command lmi showDE Mapping Frame Relay Service Interworking FRF.8Web Configuration Methods FRS Configuration OptionsTranslation Mode Fecn Mapping177 178 FRS NameSet variable attributes on a specified group CLI Configuration MethodCommand frs set group # variable value Show one of the eight groupsSet variable attributes on a specified channel FRS Overview Screen180 181 Group/Channel Level Configuration ScreenFRN Configuration Options Frame Relay Network Interworking FRF.5182 183 Port Level Configuration Options184 Channel Level Configuration Options185 CLI Configuration Methods for Port Level ManagementList all ports available to the system Show detailed information about a specific port186 Command frn set port# variable valueConfiguration Management of the Channel Level Variables Understanding the Channel Level ViewSet Configuration Variables associated with the Channels Command frn set port# channel # variable value187 188 Port Level Information ScreenChannel Level Information Screen Packet Information Screen189 Frame Relay Configuration Options Frame Relay CLI Configuration OptionsFrame Relay Ethernet Based Operations 191 Clear all Frame Relay TransportsDelete the specified transport List all active Frame Relay ChannelsClock Mode Serial Interface ConfigurationWeb Based Configuration of the Frame Relay Channel Configuration Variables AvailableShow current configuration settings Gain help about the Serial Interface193 194 Web Interface ConfigurationsPing commands from the CLI Interface Ping and Trace Route195 Trace Route from the CLI InterfaceDefine Usage ip traceroute Start Trace Route ip traceroute startPing and traceroute from the web interface Backup and Restore FeaturesBackup Configuration Restore Configuration
Related manuals
Manual 2 pages 38.76 Kb