gshdsl set DSLRateTS

E • Command Line Interface (CLI) Operation Model 3086 G.SHDSL Integrated Access Device User Guide

Example: To read the attribute ‘Version’: gshdsl show Version

To set data rate to 256K (4 * 64K):

To set terminal type to CPE mode: gshdsl set terminal remote

To show the current terminal type: gshdsl show terminal

Attribute

Type

Value

Description

 

 

 

 

Version

RO

-

The version number of the DSL driver

Platform

RO

-

The platform name of the unit e.g. 3086 or 3086

 

 

 

 

ModemState

RO

Idle

Show the state of the handshaking process:

 

 

Deactivated

Idle – The DSL chip is in idle state

 

 

Norm Oper

Deactivated – The DSL chip is deactivated

 

 

In-Progress

Normal Operation – The DSL chip is in operating (Link established)

 

 

 

In-Progress – Handshaking in process

 

 

 

 

DSLRateTS

RW

3-36

Data rate N number N=3-36. e.g. 256K data rate is N=4. The composite data rate is the cho-

 

 

 

sen number N times 64 kbps. E.g., 32 x 64 kbps = 2.048 Mbps.

 

 

 

 

DataRateI

RW

0-7

This attribute controls the size of the overhead channel. Valid input is 0-7. Default value is 0.

 

 

 

(!!Keep it as 0)

terminal

RW

Central

Central – CO unit

 

 

Remote

Remote – CPE unit

 

 

 

 

Interface

RW

Hdlc

Utopia – Data will be packaged in ATM cell format and send through the UTOPIA interface of

 

 

 

the processor

 

 

 

Hdlc – Data will be packaged in HDLC frame and send through the PCM Bus

Action

WO

Start

Start – Command the box to configure the DSL chip and start the handshaking process

 

 

Deactivate

Deactivate – Command the box to disconnect and deactivate the DSL link.

 

 

 

 

To establish the DSL link

1.One unit needs to be set to CO (central) and the other unit as CP (remote)

2.The Data rate of the 2 units have to be the same (DatarateN)

3.The interface type needs to be the same to pass data (Interface)

4.Issue the ‘Action’ command to start the handshaking process (Action Start)

Example: To set up the units to run at 2.048Mbps using ATM interface.

For CO (central) unit

gshdsl set terminal central

gshdsl set interface utopia

gshdsl set dataRateN 32

gshdsl set dataRateI 0

gshdsl set Action Start

For CPE (remote) unit

gshdsl set terminal remote

gshdsl set interface utopia

gshdsl set dataRateN 32

gshdsl set dataRateI 0

gshdsl set Action Start

168

Administering user accounts

Image 168
Contents Shdsl Integrated Access Device Patton Electronics Company, Inc Contents Basic Application Configurations Contents Specialized Configurations 113 Contacting Patton for assistance 143 Cable Recommendations 157 Contents Page About this guide AudienceStructure Precautions Factory default parameters Safety when working with electricityAbout this guide Typographical conventions used in this document General conventionsMouse conventions Chapter contents General InformationModel 3086 G.SHDSL IAD overview General attributesModel 3086 G.SHDSL IAD overview Shdsl Characteristics EthernetTDM Interface Protocol supportPPP Support ATM ProtocolsManagement Security ModelWAN DSL Rear panel connectors and switches Power connectorConsole port outlined in red RJ-11/4 DSL line port uses pins 2 and 3 of the RJ-11 port Ethernet port outlined in greenLine port outlined in yellow Product Overview Product Overview Applications OverviewInternet/Extranet Access IP/FR and TDM AccessIP/FR and Voice over DSL Product OverviewMetro Intranet Access Quick Start Installation Hardware installation Installing the AC power cordWhat you will need Connecting network cables Quick Start InstallationWeb Operation and Configuration PC ConfigurationIP address Quick Start modification IP address has now been successfully changedModel 3086 home page displays see Figure Model 3086 menu structure is shown in onModel 3086 Menu Structure Basic Application Configurations Basic Application Configurations IPoA Routed RFC Introduction Routed WAN Services Bridged WAN Services TDM PortRear panel power and interface connectors Connecting the 3086 serial port to a DTE Connecting the 3086 serial port to a DCEX.21 Ports InterfacesConfiguring the V.35 or X.21 port via DIP switches X.21 PortsDIP switches location Switch Bank S2 Switch Position Function Factory Default Selected OptionSwitch Bank S3 T1 Interface T1 Interface ConnectionT1 Interface Configuration DIP Switch ConfigurationData Rate kbps Figuration only Web Interface Configuration Line Code The 3086 T1 interface uses B8ZSE1 Interface E1 Interface ConnectionDescription of S2 options follows the table E1/CRC S3-8 Setting Web Interface Configuration Using the 3086 as a simple modem TDM data over DSL CLI configurationCLI configuration Wait for configuration saved message… Saving configuration… Web browser configuration Clear Error CountersCircuit ID Intended DSL Data RateIntended Serial Interface Data Rate DSL Rate Number of i BitTerminal Type TDM Plus Ethernet Traffic Selecting PCM mode Selecting the DSL link speedAssigning bandwidth to serial and Ethernet ports Central or Remote terminal Master/SlaveFor 3086 a at the prompt type For 3086 B typeSelect between Annex a and Annex B To select Annex B type Circuit ID Intended Serial Interface Data Rate Interface Type Using the 3086 in Routed or Bridged applications Model 3086 Remote Configuration Steps PPPoH BridgedTwo stand-alone units directly connected Ethernet extension Hdlc Pppoh BridgedLeave User name and Password blank. Click on Apply Model 3086 Central Configuration Steps PPPoH Bridged Model 3086 Remote Configuration Steps PPPoH Routed Network Extension HDLC-PPPoH RoutedModel 3086 G.SHDSL Integrated Access Device User Guide Click on Configure Basic Application Configurations Model 3086 Central Configuration Steps PPPoH Routed Using the 3086 in Routed or Bridged applications Bridged application configurations to a Dslam RFC 1483 Bridged ConfigurationDslam Connections with remote CPE units Model 3086 Remote Configuration Steps RFC 1483 Bridged Model 3086 Central Configuration Steps RFC 1483 Bridged PPPoH Bridged Configuration Dslam Connections with remote CPE units Model 3086 Central Configuration Steps PPPoH Bridged PPPoA Bridged RFC 2364 Configuration Model 3086 Remote Configuration Steps PPPoA BridgedModel 3086 CentralConfiguration Steps PPPoA Bridged VPI = VCI = LLC header mode = off Hdlc header mode = offRouted application configurations to a Dslam Model 3086 Remote Configuration Steps RFC 1483 RoutedRFC 1483 Routed Model 3086 G.SHDSL Integrated Access Device User Guide Basic Application Configurations Model 3086 Central Configuration Steps RFC 1483 Routed One IP interface was called ip1 with an IP addressIp set interface ip1 ipaddress 192.168.100.2 Dslam Connections with remote CPE units Basic Application Configurations PPPoH Routed Ip set interface ip1 ipaddress 192.168.100.2 Dslam Connections with remote CPE units Basic Application Configurations Model 3086 Central Configuration Steps PPPoH Routed Basic Application Configurations Basic Application Configurations Model 3086 Remote-Client Configuration Steps PPPoA Routed PPPoA Routed RFCUser Namefred Passwoodfredspass Click on Configure ChapBasic Application Configurations Dslam Connections with remote CPE units Model 3086 Central-Server Configuration Steps PPPoA Routed 100 101 Local IP Magic Number MRU 102103 104 105 106 Model 3086 Remote Configuration Steps IPoA Routed IPoA Routed RFC107 108 109 110 Model 3086 Central Configuration Steps IPoA Routed VPI0 VCI700 WAN IP address Click on Apply111 112 Specialized Configurations IP Configurations RouterRIP and RIPv2 Static Route Dhcp Server and RelaySpecialized Configurations 115DNS Client 116DNS Relay Mode 117IP Configurations Security Configuring the IAD 120Configuring the security interfaces Security121 Deleting a Firewall Policy 122Enabling the Firewall Firewall PortfiltersFirewall Policies Firewall policy named item0 is now deletedSecurity Triggers 124125 Scan Attack Block DurationDefault = 86400 seconds Intrusion Detection System IDS126 127 Intrusion Detection System IDS NAT Network Address Translation Enabling NAT 130Global address pool and reserved map NAT Network Address Translation131 132 Monitoring Status Status LEDs 134Diagnostics Software Upgrades ConfigurationProcedure PingDiagnostics Operating Local Analog Loopback LAL-Serial Port LoopOperating Remote Digital Loopback RDL-DSL Loop 137T1/E1 Diagnostics Network Loop138 T1/E1 Local Loop 139QRSS-BIT Error Rate Diagnostics 140Alarms T1/E1 connection StatusTransceiver Status FDL statistics T1 onlyBIT Error Rate V.52 Diagnostics 142Contacting Patton for assistance Warranty coverage Out-of-warranty serviceContact information Returns for creditReturn for credit policy RMA numbersShipping instructions Contacting Patton for assistancePage Appendix a Compliance information Safety ComplianceRadio and TV Interference FCC Part CE Declaration of ConformityAuthorized European Representative FCC Part 68 Acta StatementIndustry Canada Notice 149150 Appendix B Specifications General Characteristics Shdsl CharacteristicsEthernet 152Sync Serial Interface T1/E1 Interface 3086/RIK and RIT models only64K/G.703 Port 3086/RIF Model Protocol SupportPPP Support ATM ProtocolsManagement 154Dimensions Power and Power Supply SpecificationsSecurity Compliance Standard Requirements156 Appendix C Cable Recommendations DSL Cable Ethernet CableAdapter Foot 3 m, RJ-11/RJ-11 refer to RJ-11non-shielded port onAppendix D Physical Connectors Assuming the MDI-X switch is in the out position RJ-45 shielded 10/100 Ethernet portRJ-11 non-shielded port RJ-45 non-shielded RS-232 console port EIA-56135 M/34 Connector 35 DB-25 Female ConnectorPhysical Connectors Serial portPower input 21 DB-15 Connector E1/T1 RJ-48C ConnectorIEC 320 connector two prong 162Appendix E Command Line Interface CLI Operation 163CLI Terminology Produces a list of numbered transport objectsLocal VT-100 emulation Remote TelnetUsing the Console Command Line Interface CLI OperationThen 165Administering user accounts Setting user passwordsAdding new users Following information is returnedChanging user settings Controlling login accessControlling user access Shdsl CommandsTo establish the DSL link For CPE remote unit168 169 170 Appendix F Interworking Functions Information Interworking Functions Information LMI Configuration Options ManagementType Default Value nomaintenanceFrame Relay Local Management Interface 173MgtAutoStart Default Value False T391Value Default ValueT392Value Default Value FullReportCycle Default ValueCLI Configuration Methods Show current configurationCommand lmi show Set configuration variableFrame Relay Service Interworking FRF.8 Web Configuration MethodsFRS Configuration Options DE MappingTranslation Mode Fecn Mapping177 FRS Name 178CLI Configuration Method Command frs set group # variable valueShow one of the eight groups Set variable attributes on a specified groupSet variable attributes on a specified channel FRS Overview Screen180 Group/Channel Level Configuration Screen 181FRN Configuration Options Frame Relay Network Interworking FRF.5182 Port Level Configuration Options 183Channel Level Configuration Options 184CLI Configuration Methods for Port Level Management List all ports available to the systemShow detailed information about a specific port 185Command frn set port# variable value Configuration Management of the Channel Level VariablesUnderstanding the Channel Level View 186Set Configuration Variables associated with the Channels Command frn set port# channel # variable value187 Port Level Information Screen 188Channel Level Information Screen Packet Information Screen189 Frame Relay Configuration Options Frame Relay CLI Configuration OptionsFrame Relay Ethernet Based Operations Clear all Frame Relay Transports Delete the specified transportList all active Frame Relay Channels 191Serial Interface Configuration Web Based Configuration of the Frame Relay ChannelConfiguration Variables Available Clock ModeShow current configuration settings Gain help about the Serial Interface193 Web Interface Configurations Ping commands from the CLI InterfacePing and Trace Route 194Trace Route from the CLI Interface Define Usage ip tracerouteStart Trace Route ip traceroute start 195Backup and Restore Features Backup ConfigurationRestore Configuration Ping and traceroute from the web interface