Patton electronic Network Hardware, 275, 2715 System Diagnostics, Local Loop Idle default

Page 11

If you do not have a terminal, you may force the unit to use the DIP switches as the default configuration source by turning off the unit, set- ting all the DIP switches to the ON position, then powering on the unit. This will cause the unit to enter a special mode. Then turn off the unit and change the switch settings to the desired settings. When you turn the unit on again, the unit will be set up with the selected switch set- tings.

nDS0 Channel Configuration Menu [ Bandwidth/# Channels = 2,048k/na] (default)

The Channel Configuration Menu has a sub-menu that looks like this:

You may configure the Model 2715 to operate with any combination of active and inactive DS0 channels in this screen. When you execute the Save Changes command, the selected settings will be saved to perma- nent memory, and the system will be updated to operate with the new channel settings.

NOTE: In Unframed format, the Bandwidth Selected will display “2.048k,” and the Total Channels will display “na.” When using the DIP switches to set the bandwidth, the starting channel is always channel 1 or 0.

3.2.3 System Diagnostics

The System Diagnostics/Statistics screen looks like this:

NOTE: This screen is updated once per second.

The System Diagnostics/Statistics options and functions are described below.

aLocal Loop Idle (default)

The Local Loop is a bi-lateral loopback in which the data from the local DTE and the data from the remote unit are looped back to their respec- tive sources (See Section 5.3). Activate this loop to test the each of the DTE’s connection to the Model 2715.

The Local Loop test has four states:

Idle No user-controlled loopbacks are active.

LLThe Model 2715 is in local loopback mode.

Off The Model 2715 is in remote loopback mode or sending a pattern. Local loopback is disabled.

LocP The Model 2715 is in Local Loopback mode, and is send- ing a test pattern.

19

20

Image 11
Contents User Manual General Information Patton Model Table of ContentsWarranty Statement Tel 301 Email support@patton.com Service InformationRadio and TV Interference CE and Telecommunication Approvals2715 as the Interface between the Telco and CPE FeaturesGeneral Product Description Supported ApplicationsSwitch SW1 Line Coding ConfigurationDIP Switch Configuration Switch SET Summary TableClock Modes MULTIFRAMEG.704CRC-4 MF Unframed G.703 SW3 SW4Software Configuration Helpful Hints Introduction to Main MenuLine Coding HDB3 default System ConfigurationLine Format G.703 default Options G.703, G.704 Default Config Source Switch default Options EEPROM, Switch CRC-4 Setting Disabled default Options Enabled, DisabledCAS MF Setting Disabled default Options Enabled, Disabled 54 Loops Enabled default Options Enabled, DisabledLocal Loop Idle default System DiagnosticsSpacebar Remote Loop Idle defaultTest Pattern Idle default Options Idle or Sending Error Insertion Off default Options On, OffUnit Options Current DIP Switch SettingsPassword NI StatusNetwork Interface Connection DTE Interface ConnectionRXD Power ConnectionLED Descriptions TXDERR Loop V.54 & Telco DiagnosticsLOS ALM2047 BIT Error Rate V.52 DiagnosticsError Insertion to on 511Patton Model Cable Recommendations SpecificationsDB9F Appendix CJumper Position for Power via Pin KK Connector, Terminal InterfacePatton Model Power Supply Interface Jumper Position for Power via DC Power Jack defaultCopyright Patton Electronics Company All Rights Reserved