Use this option to select the test pattern used to test the link.
NI STATUS
The Network interface (NI) status is shown
in the middle of the Diagnostics/StatisticsRCL screen. The brackets are empty when the
link is operating normally. Only one error message is provided
Receiver Carrier Loss [RCL] occurs when 255 consecutive zeros have been detected at the network interface. RCL clears when a pulse is detected.
Current DIP Switch Settings
The Switch settings are displayed here to facilitate troubleshooting your unit without opening up the unit first.
3.2.4 Unit Options
The Unit Options screen looks like this (factory default):
aHeader Line 1 & b Header Line 2
Headers 1 and 2 are provided for easy identification of your unit after installation. You may want to give each unit a unique name via the header lines to help distinguish one unit from another. You can enter a header up to 40 letters long. Two lines provide 80 letters for your use. That’s a lot of flexibility!
cPassword
The Password facility provides security by allowing only those who know the correct password to configure the unit via the control port. You can still configure the unit via the DIP switches. The password can be up to 16 characters long, with no restriction on the combination of characters you can use, so be sure to remember the password. The password is case sensitive. If you lose your password, you will lose the ability to access the unit via the control port.
23 | 24 |