NOTE: When the data rate is set to 2.048Mb/s, then the unit is forced into G.703 mode, and it transmits user data on all 32 timeslots. There is no framing information; therefore, the CAS MF (SW2)and
3.2 SOFTWARE CONFIGURATION
The Model 2715 features a
1)Plug the
NOTE: If your terminal uses a
2)Power up the terminal and set its
9600 Baud
8 data bits, 1 stop bit, no parity Local echo off
ANSI or
Xon/Xoff software flow control enabled
3)Here is an example of a terminal emulator setup session. In normal font are the various parameter types. In bold type are the values that should be used for best results. Your terminal program’s setup screen may differ from this one:
Baud rate: 9600 | Parity: None | Data Length: 8 | Stop Bits: 1 |
Default terminal type: | VT100 |
| |
Local Echo: |
| Off |
|
Add Line Feeds after CRs: | Off |
| |
Received Backspace Destructive: | O n |
| |
Backspace key sends: | B S |
| |
XON/XOFF software flow control: | O n |
| |
CTS/RTS hardware flow control: | Off |
| |
DSR/DTR hardware flow control: | Off |
|
4)When the unit is first turned on, the terminal screen may appear blank. Press the [Enter] key. If your serial connection is good, then the unit will immediately display a password prompt. The following message will appear in the middle of the screen:
Patton Electronics
Menu Management
Enter Password: _
5)Type in the password and press [Enter]. The factory default password for the unit is:
patton
NOTE: The password is case sensitive. If the entry is incor- rect, the password screen will clear and prompt you again for the correct password. The password you enter will not be shown. For security, asterisks will be displayed for each letter you type. The maximum length of the password, which can include any character the terminal can generate, is 16 charac- ters.
6)The Model 2715 will then display the Main Menu screen.
11 | 12 |