SpectraLink 8000 SVP Server: Administration Guide for SIP
Connect SVP Server to LAN
Using a Cat. 5 cable, connect the NETWORK port on the SVP Server to the connecting port on the Ethernet switch.
Connect power
1.Once the units have been properly grounded, connect the power plug from the AC adapter to the jack labeled PWR on the SVP Server.
Use only the provided Class II AC Adapter with output 24V DC, 1A.
2.Plug the AC adapter into an 110V AC outlet to apply power to the SVP Server.
3.Verify that leakage current ("touch" current) is below 250 μA rms on exposed metal surfaces.
4.If leakage is excessive, power off the system and
5.The system will cycle through diagnostic testing and the LEDs will blink for about one minute. When the system is ready for use:
—The ERROR LED should be off.
—Status 1 should be blinking.
20 | PN: |